A 4-Channel sEMG ASIC with Real-Time Muscle Fatigue Feature Extraction

被引:1
作者
Tu, Wei [1 ,2 ]
Cacho-Soblechero, Miguel [1 ,2 ]
Terracina, Dan [1 ,2 ,3 ]
Strutton, Paul H. [3 ]
Georgiou, Pantelis [1 ,2 ]
机构
[1] Imperial Coll London, Dept Elect & Elect Engn, London, England
[2] Imperial Coll London, Ctr Bioinspired Technol, Inst Biomed Engn, London, England
[3] Imperial Coll London, Nick Davey Lab, Dept Surg & Canc, Sir Michael Uren Hub,Fac Med, White City Campus, London, England
来源
2021 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS) | 2021年
关键词
sEMG; Muscle Fatigue; Low Back Pain; Feature Extraction; AMPLIFIER; CMOS;
D O I
10.1109/ISCAS51556.2021.9401781
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a 4 channel ASIC for sEMG sensing with in-built muscle fatigue and activity feature extraction. Each channel filters and conditions the electrode signal in parallel, while extracting key features for Low Back Pain (LBP) fatigue monitoring and forecasting - Zero Crossing rate and Root Mean Square through sEMG Envelope. The channels are integrated with a Transimpedance Amplifier, an 10-Bit ADC and a Digital Control Unit to digitise and enable transmission of extracted features. Fabricated in TSMC 180nm, these channels present a compact form factor (90 mu m x 630 mu m) and a low power consumption (42.61 mu W), ideal characteristic for wearable devices utilised for long-term monitoring of activities.
引用
收藏
页数:5
相关论文
共 26 条
[1]  
[Anonymous], 2015, ADS1298 TEX INSTR IN
[2]   256-Channel Neural Recording and Delta Compression Microsystem With 3D Electrodes [J].
Aziz, Joseph N. Y. ;
Abdelhalim, Karim ;
Shulyzki, Ruslana ;
Genov, Roman ;
Bardakjian, Berj L. ;
Derchansky, Miron ;
Serletis, Demitre ;
Carlen, Peter L. .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2009, 44 (03) :995-1005
[3]   A Dual-Sensing Thermo-Chemical ISFET Array for DNA-Based Diagnostics [J].
Cacho-Soblechero, Miguel ;
Malpartida-Cardenas, Kenny ;
Cicatiello, Chiara ;
Rodriguez-Manzano, Jesus ;
Georgiou, Pantelis .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2020, 14 (03) :477-489
[4]  
Cerone GL, 2017, BIOMED CIRC SYST C
[5]   Voluntary activation of trunk extensors appears normal in young adults who have recovered from low back pain [J].
Chiou, S. Y. ;
Jeevathol, A. ;
Odedra, A. ;
Strutton, P. H. .
EUROPEAN JOURNAL OF PAIN, 2015, 19 (10) :1506-1515
[6]   Surface Electromyography Signal Processing and Classification Techniques [J].
Chowdhury, Rubana H. ;
Reaz, Mamun B. I. ;
Ali, Mohd Alauddin Bin Mohd ;
Bakar, Ashrif A. A. ;
Chellappan, Kalaivani ;
Chang, Tae. G. .
SENSORS, 2013, 13 (09) :12431-12466
[7]   A 1.8 μW 60 nV/√Hz Capacitively-Coupled Chopper Instrumentation Amplifier in 65 nm CMOS for Wireless Sensor Nodes [J].
Fan, Qinwen ;
Sebastiano, Fabio ;
Huijsing, Johan H. ;
Makinwa, Kofi A. A. .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2011, 46 (07) :1534-1543
[8]   Is the Use of a Low-Cost sEMG Sensor Valid to Measure Muscle Fatigue? [J].
Fuentes del Toro, Sergio ;
Santos-Cuadros, Silvia ;
Olmeda, Ester ;
Alvarez-Caldas, Carolina ;
Diaz, Vicente ;
Luis San Roman, Jose .
SENSORS, 2019, 19 (14)
[9]   A versatile integrated circuit for the acquisition of biopotentials [J].
Harrison, Reid R. .
PROCEEDINGS OF THE IEEE 2007 CUSTOM INTEGRATED CIRCUITS CONFERENCE, 2007, :115-122
[10]   A low-power low-noise CMOS amplifier for neural recording applications [J].
Harrison, RR ;
Charles, C .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2003, 38 (06) :958-965