Gas chromatographic mass spectrometric identification and quantification of aniline after extraction from serum and derivatization with 2,2,2-trichloroethyl chloroformate, a novel derivative

被引:39
作者
Dasgupta, A [1 ]
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Pathol & Lab Med, Houston, TX 77030 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 1998年 / 716卷 / 1-2期
关键词
derivatization; GC; aniline; 2,2,2-trichloroethyl chloroformate;
D O I
10.1016/S0378-4347(98)00286-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aniline is widely used as an intermediate in the synthesis of dyes. It is also used in the manufacture of pharmaceuticals, photographic developers, shoe polish, etc. Exposure to aniline is toxic because it produces methemoglobin. In humans, blood methemoglobin levels are often measured as an index of exposure to aniline. Here a method is described for identification and quantification of aniline by gas chromatography-mass spectrometry after extraction from human serum and derivatization with 2,2,2-trichloroethyl chloroformate. Aniline, along with the internal standard N-methylaniline, were extracted from alkaline serum using chloroform. Aniline and the internal standard were derivatized with 50 mu l 2,2,2-trichloroethyl chloroformate. After evaporating excess derivatizing reagent, the residue was reconstituted in 50 mu l chloroform and injected into the gas chromatographic-mass spectrometry (GC-MS) system. A positive identification of derivatized aniline can be made by observing strong molecular ions at m/z 267 and 269. Similarly, the derivatized internal standard showed strong molecular ions at mit 281 and 283. The within-run and between-run precisions of the assay were 3.61 and 5.92%, respectively, at an aniline concentration of 5 mg/l. The assay was linear for serum aniline concentrations of 0.5-25.0 mg/l. The detection limit was 0.1 mg/l. The assay was not affected by lipemia, hemolysis or high bilirubin concentration in serum. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:354 / 358
页数:5
相关论文
共 10 条
  • [1] CHANG MJW, 1993, B ENVIRON CONTAM TOX, V51, P494
  • [2] DREISBACH RH, 1983, HDB POISONING
  • [3] Ellenhorn MJ, 1997, ELLENHORNS MEDICAL T, V2nd, P1496
  • [4] KEWNEY TE, 1984, W J MED, V140, P282
  • [5] BIOLOGICAL MONITORING FOR INDUSTRIAL EXPOSURE TO CYANOGENIC AROMATIC NITRO AND AMINO COMPOUNDS
    LINCH, AL
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1974, 35 (07): : 426 - 432
  • [6] ACUTE ANILINE POISONING TREATED BY HEMODIALYSIS - REPORT OF CASE
    LUBASH, GD
    PHILLIPS, RE
    BONSNES, RW
    SHIELDS, JD
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1964, 114 (04) : 530 - &
  • [7] MILLER RJ, 1988, CLIN TOXICOL, V26, P357
  • [8] PACSERI J, 1961, PURE APPL CHEM, V3, P313
  • [9] PIOTROWSKI JK, 1977, EXPOSURE TESTS ORGAN, P70
  • [10] RAMSAY DHE, 1959, LANCET, V1, P910