Effect of focused protocol on reducing radiation dose for children who require computed tomography for suspected appendicitis

被引:5
作者
Roberts, Suzanne [1 ]
Goldwasser, Bernard [2 ]
Nixon, Abigail F. [1 ]
Borkar, Deeksha [3 ]
Brookman, Max [4 ]
Fox, Carolyn E. [5 ]
Rosenfeld, Cyril [6 ]
Meltzer, James A. [1 ]
机构
[1] Jacobi Med Ctr, Div Emergency Med, Dept Pediat, Bronx, NY 10461 USA
[2] Jacobi Med Ctr, Div Pediat, Dept Radiol, Bronx, NY USA
[3] Univ Minnesota, Dept Pediat, Minneapolis, MN 55455 USA
[4] Jacobi Med Ctr, Dept Pediat, Bronx, NY USA
[5] Oregon Hlth & Sci Univ, Div Pediat, Dept Emergency Med, Portand, OR USA
[6] Jacobi Med Ctr, Dept Radiol, Bronx, NY USA
关键词
Appendicitis; Focused; Limited; Computed tomography; Abdominal pain; Right lower quadrant; Children; Radiation; CT; CANCER; RISKS;
D O I
10.1016/j.ajem.2021.07.005
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Despite efforts to incorporate ultrasound into the evaluation of children for appendicitis, computed tomography (CT) is often used to aid in its diagnosis. CT scans, however, expose children to a considerable amount of radiation. In 2017, our institution began using a height-based Focused CT protocol for children with suspected appendicitis in need of CT. Objective: To compare the radiation dose received by children with suspected appendicitis who underwent a Standard Cr of the abdomen and pelvis (CTAP) with that of a Focused CT. Methods: We conducted a retrospective study of children <18 years who underwent a CT scan for suspected appendicitis (2014-2020). We included all patients whose indication for CT was "appendicitis" or "right lower quadrant pain" and excluded those whose Cr scan record lacked a radiation dose report. The effective radiation dose delivered was calculated using the dose-length product from the dose report. We compared the effective dose of those who received a Standard CTAP to those who received a Focused Cr. To account for differences in radiation dose over time and by CT scanner, analyses were adjusted for CT dose index volume (CTDIvol) and size-specific dose estimate (SSDE) using quantile regression. Results: A total of 474 patients who underwent CT were included. Prior to CT, 362(76%) had received an ultrasound. In total, 309(65%) patients underwent a Standard CTAP and 165(35%) underwent a Focused CT. The appendix was identified in 259(84%) Standard CTAPs compared to 151(92%) Focused CTs (p = 0.02). Compared to the Standard CTAP, children who received a Focused CT were exposed to a significantly lower effective dose (relative difference: CTDI-adjusted -13%[95%CI:-21,-5]; SSDE-adjusted -14%[95% CI:-24,-31). Conclusions: Our height-based Focused Cr protocol reduces radiation for children undergoing CT evaluation for suspected appendicitis without sacrificing diagnostic accuracy. Further study is needed to validate these findings at other institutions. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:76 / 79
页数:4
相关论文
共 50 条
[31]   Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma [J].
Qi, Zhihua ;
Gates, Erica L. ;
O'Brien, Maureen M. ;
Trout, Andrew T. .
PEDIATRIC RADIOLOGY, 2018, 48 (02) :196-203
[32]   A positron emission tomography/computed tomography (PET/CT) acquisition protocol for CT radiation dose optimization [J].
Wu, TH ;
Chu, TC ;
Huang, YH ;
Chen, LK ;
Mok, SP ;
Lee, JK ;
Yeu-Sheng, T ;
Lee, JJS .
NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (04) :323-330
[33]   Implementation of ultrasound and fast magnetic resonance imaging pathway reduces computed tomography utilization in children with suspected appendicitis [J].
Gabrielle Steinl ;
David Grabski ;
Mark Fleming ;
Daniel Levin ;
Eugene McGahren ;
William McCullough ;
Jeffrey Gander .
Pediatric Surgery International, 39
[34]   Pediatric craniosynostosis computed tomography: an institutional experience in reducing radiation dose while maintaining diagnostic image quality [J].
Izabella L. Barreto ;
Ibrahim S. Tuna ;
Dhanashree A. Rajderkar ;
Jessica A. Ching ;
Lance S. Governale .
Pediatric Radiology, 2022, 52 :85-96
[35]   Pediatric craniosynostosis computed tomography: an institutional experience in reducing radiation dose while maintaining diagnostic image quality [J].
Barreto, Izabella L. ;
Tuna, Ibrahim S. ;
Rajderkar, Dhanashree A. ;
Ching, Jessica A. ;
Governale, Lance S. .
PEDIATRIC RADIOLOGY, 2022, 52 (01) :85-96
[36]   Low dose computed tomography pulmonary angiography protocol for imaging pregnant patients: Can dose reduction be achieved without reducing image quality? [J].
Halpenny, Darragh ;
Park, Brian ;
Alpert, Jeffrey ;
Latson, Larry, Jr. ;
Kim, Nancy ;
Babb, James ;
Shiau, Maria ;
Ko, Jane .
CLINICAL IMAGING, 2017, 44 :101-105
[37]   Negative Bronchoscopy or Computed Tomography Radiation in Children with Suspected Foreign Body Aspiration? Pros and Cons [J].
Celikkaya, Mehmet Emin ;
Atici, Ahmet ;
Korkmaz, Inan ;
Karadag, Mehmet ;
El, Cigdem ;
Akcora, Buelent .
TOMOGRAPHY, 2025, 11 (02)
[38]   Reducing radiation exposure from computed tomography of the brain in children - report of a practical approach [J].
Wong, Sui-To ;
Yiu, Gwendolin ;
Poon, Yiu-Man ;
Yuen, Ming-Keung ;
Fong, Dawson .
CHILDS NERVOUS SYSTEM, 2012, 28 (05) :681-689
[39]   Reducing radiation exposure from computed tomography of the brain in children — report of a practical approach [J].
Sui-To Wong ;
Gwendolin Yiu ;
Yiu-Man Poon ;
Ming-Keung Yuen ;
Dawson Fong .
Child's Nervous System, 2012, 28 :681-689
[40]   Reduced Kilovoltage in Computed Tomography-Guided Intervention in a Community Hospital: Effect on the Radiation Dose [J].
Rezazadeh, Saman ;
Co, Steven J. ;
Bicknell, Simon .
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2014, 65 (04) :345-351