Rapid and Accurate Pressure Sensing Device for Direct Measurement of Intraocular Pressure

被引:10
作者
Gopesh, Tilvawala [1 ]
Camp, Andrew [2 ,3 ]
Unanian, Michael [1 ]
Friend, James [1 ]
Weinreb, Robert N. [2 ,3 ]
机构
[1] Univ Calif San Diego, Dept Mech & Aerosp Engn, Medically Adv Devices Lab, Ctr Med Devices & Instrumentat, La Jolla, CA USA
[2] Univ Calif San Diego, Hamilton Glaucoma Ctr, Shiley Eye Inst, 9415 Campus Point Dr, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Viterbi Family Dept Ophthalmol, 9415 Campus Point Dr, La Jolla, CA 92093 USA
基金
美国国家科学基金会;
关键词
glaucoma; intraocular pressure; manometry; KERATOPROSTHESIS; IOP; CHALLENGE; TONOMETRY; GLAUCOMA; OUTCOMES; INJURY;
D O I
10.1167/tvst.9.3.28
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Intraocular pressure (IOP) is the primary modifiable risk factor for glaucoma. Current devices measure IOP via the dynamic response of the healthy cornea and do not provide the accurate IOP measurements for patients with altered corneal biomechanics. We seek to develop and test an accurate needle-based IOP measurement device that is not cornea dependent. Methods: Our device combines a high-resolution pressure microsensor with 30- and 33-gauge Luer lock needles to provide IOP measurements via a microcontroller and USB interface to a computer. The device was calibrated in a membrane chamber and then tested and validated in the anterior chamber and post-vitrectomy vitreous chamber of rabbit eyes. The results were compared to Tonopen readings across a pressure range of 0 to 100 mm Hg, imposed in increments of 10 mm Hg. Results: Both the needle based sensor device and the Tonopen demonstrated a linear relationship with changes in imposed pressure. The Tonopen was found to consistently underestimate the IOP both in the anterior and vitreous chambers. The Tonopen exhibited a significantly greater error than our needle-based sensor device. With increased pressure (>30 mm Hg), the error of the Tonopen increased, whereas the error of our device did not. The 30-gauge needle produces an insignificant improvement in accuracy over the 33-gauge needle. Conclusions: A needle-based sensor device enables accurate IOP measurements over a broad range of induced IOP. Translational Relevance: Direct measurement of IOP in the anterior chamber circumvents the influence of corneal parameters on IOP measurement.
引用
收藏
页数:9
相关论文
共 37 条
[1]  
[Anonymous], 2014, Review Ophthalmology, P62
[2]   An implantable microfluidic device for self-monitoring of intraocular pressure [J].
Araci, Ismail E. ;
Su, Baolong ;
Quake, Stephen R. ;
Mandel, Yossi .
NATURE MEDICINE, 2014, 20 (09) :1074-1078
[3]   The gradient of retinal functional changes during acute intraocular pressure elevation [J].
Bui, BV ;
Edmunds, B ;
Cioffi, GA ;
Fortune, B .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (01) :202-213
[4]   Change in Intraocular pressure measurements after LASIK - The effect of the refractive correction and the lamellar flap [J].
Chang, DH ;
Stulting, RD .
OPHTHALMOLOGY, 2005, 112 (06) :1009-1016
[5]   An acute intraocular pressure challenge to assess retinal ganglion cell injury and recovery in the mouse [J].
Crowston, Jonathan G. ;
Kong, Yu Xiang G. ;
Trounce, Ian A. ;
Dang, Trung M. ;
Fahy, Eamonn T. ;
Bui, Bang V. ;
Morrison, John C. ;
Chrysostomou, Vicki .
EXPERIMENTAL EYE RESEARCH, 2015, 141 :3-8
[6]   24-Hour IOP Telemetry in the Nonhuman Primate: Implant System Performance and Initial Characterization of IOP at Multiple Timescales [J].
Downs, J. Crawford ;
Burgoyne, Claude F. ;
Seigfreid, William P. ;
Reynaud, Juan F. ;
Strouthidis, Nicholas G. ;
Sallee, Verney .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) :7365-7375
[7]   TIME TO ABOLISH GOLD STANDARD [J].
DUGGAN, PF .
BRITISH MEDICAL JOURNAL, 1992, 304 (6841) :1568-1569
[8]   Telemetric Intraocular Pressure Monitoring after Boston Keratoprosthesis Surgery [J].
Enders, Philip ;
Hall, Jonathan ;
Bornhauser, Marco ;
Mansouri, Kaweh ;
Altay, Lebriz ;
Schrader, Stefan ;
Dietlein, Thomas S. ;
Bachmann, Bjoern O. ;
Neuhann, Thomas ;
Cursiefen, Claus .
OPHTHALMOLOGY, 2019, 126 (02) :322-324
[9]   Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonomet [J].
Francis, Brian A. ;
Hsieh, Amy ;
Lai, Mei-Ying ;
Chopra, Vikas ;
Pena, Fernando ;
Azen, Stanley ;
Varma, Rohit .
OPHTHALMOLOGY, 2007, 114 (01) :20-26
[10]   Long-term outcomes of the aphakic snap-on Boston type I keratoprosthesis at the Bascom Palmer Eye Institute [J].
Gibbons, Allister ;
Leung, Ella H. ;
Haddock, Luis J. ;
Medina, Carlos A. ;
Fernandez, Viviana ;
Parel, Jean-Marie A. ;
Durkee, Heather A. ;
Amescua, Guillermo ;
Alfonso, Eduardo C. ;
Perez, Victor L. .
CLINICAL OPHTHALMOLOGY, 2018, 12 :331-337