Micro flow injection ICP-MS analysis of high matrix samples: an investigation of its capability to measure trace elements in iron meteorites

被引:3
作者
Holdship, Phil [1 ]
Bonnand, Pierre [2 ]
Price, David [3 ]
Watson, Paul [4 ]
机构
[1] Univ Oxford, Dept Earth Sci, Oxford OX1 3AN, England
[2] Univ Clermont Auvergne, CNRS, Lab Magmas & Volcans, F-63000 Clermont Ferrand, France
[3] PerkinElmer, Seer Green HP9 2FX, England
[4] Elemental Sci, Warrington WA1 4AE, Cheshire, England
关键词
PLASMA-MASS-SPECTROMETRY; CHEMICAL CLASSIFICATION; GEOLOGICAL-MATERIALS; PLATINUM-GROUP; IIIAB;
D O I
10.1039/c8ja00162f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The coupling of a micro-flow injection sample introduction system to a highly versatile quadrupole ICP-MS (FI-ICP-MS) has been demonstrated to achieve accurate and precise trace element measurements for several iron meteorites. Measurements were made for the trace siderophile elements, Ru, Au, Rh, Pd, Ir, Pt, Ga, Cr, Cu and Re, where results present good agreements for most metals to duplicate samples also measured by a sector-field ICP-MS (ICP-SFMS). A major advantage for trace element measurements by flow-injection ICP-MS is the added flexibility to increase the total dissolved solids (TDS) concentrations of the working solutions above the 2000 g g(-1) ICP-MS limit. The FI-ICP-MS technique used in this study allowed the sample digests to be measured directly, where the TDS concentrations were 2.5 times the above limit. The data generated clearly demonstrate that the micro-flow inputs of the high matrix material never overloaded the plasma or compromised on instrument performance. Without the need for extra dilutions a better detection capability for most elements was found in comparison to those made by the ICP-SFMS, where all method detection limits were below 0.1 g g(-1), apart from Ru and Ga. Furthermore, it was evident from the reduced sample preparation time, together with measurement times of less than 7 minutes per sample, that the FI-ICP-MS analysis was a much more rapid technique. The accuracy of the FI-ICP-MS technique was tested from the measurement of two synthetic iron meteorites. A selection of elements, including Cr, Ga, Ru, Ir and Re, gained absolute error values better than +/- 5%, where Re, the analyte with the lowest concentration, reported the lowest absolute error, with a value of less than +/- 1%. Precision, determined from two times the relative standard deviation of repeat measurements of the synthetic solutions (n = 7), gained values less than 10% for all elements.
引用
收藏
页码:1941 / 1953
页数:13
相关论文
共 34 条
[1]   Multielemental analysis of Mn-Fe nodules by ICP-MS:: optimisation of analytical method [J].
Axelsson, MD ;
Rodushkin, I ;
Ingri, J ;
Öhlander, B .
ANALYST, 2002, 127 (01) :76-82
[2]   Solubility of platinum in aqueous solutions at 25°C and pHs 4 to 10 under oxidizing conditions [J].
Azaroual, M ;
Romand, B ;
Freyssinet, P ;
Disnar, JR .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2001, 65 (24) :4453-4466
[3]  
Benedix GK, 1997, METEORIT PLANET SCI, V32, pA11
[4]   Oxidized conditions in iron meteorite parent bodies [J].
Bonnand, P. ;
Halliday, A. N. .
NATURE GEOSCIENCE, 2018, 11 (06) :401-+
[5]   Application of ICP-MS, INAA and RNAA to the determination of some "difficult" elements in infant formulas [J].
Chajduk, Ewelina ;
Polkowska-Motrenko, Halina .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 311 (02) :1347-1353
[6]   The Bagnone iron meteorite (Tuscany, Italy): History, mineralogy, and chemical classification [J].
D'Orazio, M ;
Folco, L ;
Perchiazzi, N .
METEORITICS & PLANETARY SCIENCE, 2004, 39 (08) :A133-A138
[7]   Chemical analysis of iron meteorites by inductively coupled plasma-mass spectrometry [J].
D'Orazio, M ;
Folco, L .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2003, 27 (03) :215-225
[8]   Rapid determination of 26 elements in iron meteorites using matrix removal and membrane desolvating quadrupole ICP-MS [J].
Duan, Xiaoxia ;
Regelous, Marcel .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (12) :2379-2387
[9]  
Faure G., 1998, Principles and applications of geochemistry, V2nd
[10]   Rhodium, gold and other highly siderophile element abundances in chondritic meteorites [J].
Fischer-Goedde, M. ;
Becker, H. ;
Wombacher, F. .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2010, 74 (01) :356-379