Fixed angle devices versus multiple cancellous screws: What does the evidence tell us?

被引:32
作者
Hoshino, C. Max [1 ]
O'Toole, Robert V. [2 ]
机构
[1] Harbor UCLA Med Ctr, Dept Orthopaed, Torrance, CA 90509 USA
[2] Univ Maryland, Sch Med, Dept Orthopaed, R Adams Cowley Shock Trauma Ctr, Baltimore, MD 21201 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷 / 03期
关键词
Femoral neck fracture; Fixed angle device; Multiple cancellous screws; Hip fracture; Avascular necrosis; Nonunion; Internal fixation; FEMORAL-NECK FRACTURES; INTERNAL-FIXATION TECHNIQUES; DISPLACED FRACTURES; HIP; ARTHROPLASTY; IMPLANT; FEMUR; PLATE; BONE; METAANALYSIS;
D O I
10.1016/j.injury.2014.12.008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Complications, including nonunion and avascular necrosis, are relatively common after internal fixation of a femoral neck fracture. Young patients are particularly impacted by these complications as salvage options often result in a suboptimal functional result. The quality of reduction appears to be of primary importance; however, it is unknown whether the choice of internal fixation affects the incidence of complications. In this article, we present the rationale and evidence for available internal fixation options. Current evidence is insufficient to recommend an optimal method of internal fixation, and this review demonstrates the need for high-quality randomised, controlled trials to study this problem. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:474 / 477
页数:4
相关论文
共 27 条
[1]   Vertically oriented femoral neck fractures: Mechanical analysis of four fixation techniques [J].
Aminian, Arash ;
Gao, Fan ;
Fedoriw, Wasyl W. ;
Zhang, Li-Qun ;
Kalainov, David M. ;
Merk, Bradley R. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (08) :544-548
[2]  
[Anonymous], ORTH TRAUM ASS ANN M
[3]  
Baitner AC, 1999, CLIN ORTHOP RELAT R, P300
[4]   Catastrophic Failure After Open Reduction Internal Fixation of Femoral Neck Fractures With a Novel Locking Plate Implant [J].
Berkes, Marschall B. ;
Little, Milton T. M. ;
Lazaro, Lionel E. ;
Cymerman, Rachel M. ;
Helfet, David L. ;
Lorich, Dean G. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (10) :E170-E176
[5]   Operative management of displaced femoral neck fractures in elderly patients - An international survey [J].
Bhandari, M ;
Devereaux, PJ ;
Tornetta, P ;
Swiontkowski, MF ;
Berry, DJ ;
Haidukewych, G ;
Schemitsch, EH ;
Hanson, BP ;
Koval, K ;
Dirschl, D ;
Leece, P ;
Keel, M ;
Petrisor, B ;
Heetveld, M ;
Guyatt, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09) :2122-2130
[6]   Internal fixation compared with arthroplasty for displaced fractures of the femoral neck - A meta-analysis [J].
Bhandari, M ;
Devereaux, PJ ;
Swiontkowski, MF ;
Tornetta, P ;
Obremskey, W ;
Koval, KJ ;
Nork, S ;
Sprague, S ;
Schemitsch, EH ;
Guyatt, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (09) :1673-1681
[7]   Optimal Internal Fixation for Femoral Neck Fractures: Multiple Screws or Sliding Hip Screws? [J].
Bhandari, Mohit ;
Tornetta, Paul, III ;
Hanson, Beate ;
Swiontkowski, Marc F. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (06) :403-407
[8]  
BLAIR B, 1994, CLIN ORTHOP RELAT R, P256
[9]   Comparison of internal fixation with total hip replacement for displaced femoral neck fractures -: Randomized, controlled trial performed at four years [J].
Blomfeldt, R ;
Törnkvist, H ;
Ponzer, S ;
Söderqvist, A ;
Tidermark, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (08) :1680-1688
[10]   Predictable Healing of Femoral Neck Fractures Treated With Intraoperative Compression and Length-Stable Implants [J].
Boraiah, Sreevathsa ;
Paul, Omesh ;
Hammoud, Sommer ;
Gardner, Michael J. ;
Helfet, David L. ;
Lorich, Dean G. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 69 (01) :142-147