Systematic development of an enzymatic phosphorylation assay compatible with mass spectrometric detection

被引:25
作者
de Boer, AR
Letzel, T
Lingeman, H
Irth, H
机构
[1] Vrije Univ Amsterdam, Fac Sci, Dept Chem & Pharmaceut Sci, Sect Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
[2] Tech Univ Munich, Dept Basic Life Sci, Chair Biopolymer Chem, D-85354 Freising Weihenstephan, Germany
关键词
ESI-MS; mass spectrometry; PKA; peptide phosphorylation; inhibition reaction; quantitative analysis;
D O I
10.1007/s00216-005-3070-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The enzymatic peptide phosphorylation by cAMP-dependent protein kinase A (PKA) was optimized and monitored by means of electrospray ionization mass spectrometry (ESI-MS). The direct detection of phosphorylated peptides by MS renders labeling unnecessary, reduces time and labor, due to less initial sample pretreatment. In this study the phosphorylation of the peptide malantide by PKA was performed in batch and reaction compounds were detected by ESI-MS after the incubation time. The subsequent product quantitation was accomplished by using one-point normalization. Applying this set-up, optimum solvent conditions (such as salt and modifier content), concentrations of essential reaction compounds (such as cAMP, Mg2+ and ATP), and the influence of reaction properties (such as pH and reaction time) were determined. The reaction milieu has to be suitable for both, the enzymatic reaction and the mass spectrometric detection. We found that the modifier content and the pH value had to be changed after the enzymatic reaction occurred. Through the addition of methanol and acetic acid, the reaction stopped immediately and a more sensitive mass spectrometric detection could be obtained simultaneously. Furthermore, an inhibitor study was performed, testing the inhibition potency of three protein kinase A inhibitors (PKIs). IC50 values were determined and used to calculate the K-i values, that were 7.4, 19.0 and 340.0 nmol/L for PKI(6-22)amide, PKI(5-24)amide, and PKI(14-24)amide, respectively. These data vary between factor 4.4 (for PKI(6-22)amide) and 8.3 (for PKI(5-24)amide) compared to the Ki values described in literature. However, the Ki values are in good agreement with the data mainly obtained by fluorescence- or radio activity-based methods. Nevertheless, our results indicate that ESI-MS is a realistic alternative to radioactivity and fluorescence detection in determining enzymatic activity. Furthermore we were able to illustrate its high potential as a quantitative detection method.
引用
收藏
页码:647 / 655
页数:9
相关论文
共 53 条
  • [1] Phosphorylation of phenylalanine ammonia-lyase: evidence for a novel protein kinase and identification of the phosphorylated residue
    Allwood, EG
    Davies, DR
    Gerrish, C
    Ellis, BE
    Bolwell, GP
    [J]. FEBS LETTERS, 1999, 457 (01) : 47 - 52
  • [2] USE OF ELECTROSPRAY MASS-SPECTROMETRY TO DIRECTLY OBSERVE AN ACYL ENZYME INTERMEDIATE IN BETA-LACTAMASE CATALYSIS
    APLIN, RT
    BALDWIN, JE
    SCHOFIELD, CJ
    WALEY, SG
    [J]. FEBS LETTERS, 1990, 277 (1-2) : 212 - 214
  • [3] Monitoring enzyme catalysis with mass spectrometry
    Bothner, B
    Chavez, R
    Wei, J
    Strupp, C
    Phung, Q
    Schneemann, A
    Siuzdak, G
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 2000, 275 (18) : 13455 - 13459
  • [4] CHENG HC, 1986, J BIOL CHEM, V261, P989
  • [5] CHENG Y, 1973, BIOCHEM PHARMACOL, V22, P3099
  • [6] Activated 3′,5′-cyclic AMP-dependent protein kinase is sufficient to induce neuroendocrine-like differentiation of the LNCaP prostate tumor cell line
    Cox, ME
    Deeble, PD
    Bissonette, EA
    Parsons, SJ
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 2000, 275 (18) : 13812 - 13818
  • [7] On-line coupling of high-performance liquid chromatography to a continuous-flow enzyme assay based on electrospray ionization mass spectrometry
    de Boer, AR
    Letzel, T
    van Elswijk, DA
    Lingeman, H
    Niessen, WMA
    Irth, H
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (11) : 3155 - 3161
  • [8] A strategy for the determination of enzyme kinetics using electrospray ionization with an ion trap mass spectrometer
    Ge, X
    Sirich, TL
    Beyer, MK
    Desaire, H
    Leary, JA
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (21) : 5078 - 5082
  • [9] GLASS DB, 1989, J BIOL CHEM, V264, P8802
  • [10] GLASS DB, 1989, J BIOL CHEM, V264, P14579