Autoradiography in BNCT: a preliminary study for a novel technique

被引:0
作者
Ruffolo, MD [1 ]
de la Hoz, AP [1 ]
Saint Martin, G [1 ]
Cruz, GS [1 ]
Bernaola, OA [1 ]
机构
[1] Univ Nacl Gen San Martin, Buenos Aires, DF, Argentina
来源
PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4 | 2000年 / 22卷
关键词
nuclear track; BNCT; autoradiography; dosimetry;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In order to simplify the process and handling of the samples detector-tissue, during the developing of autoradiography process used in BNCT, were herein propose an alternative to conventional techniques. In so we employed: 1.- Thin Makrofol-E and Polyvinil chloride acetate fell as detector and tissue protector respectively. 2.- Two teflon rings to support the samples (detector-protector-tissue) where all the following steps can be carried on minimizing the sample handling. Those rings provide a mechanical support for the external cover of tissue during the etching attack and for the mounting of the glass slide during the microscope observation. 3.- A silicon sealing replacing the glycerol/gelatin is used as tissue protector thus, decreasing the hardening time from 2 days at 4 degreesC to 25 minutes at room temperature. 4.- A drop of fluorescein between the Makrofol E and the slide is included, in order to increasing the track resolution by microscopy.
引用
收藏
页码:876 / 878
页数:3
相关论文
共 50 条
  • [1] Preliminary modeling of BNCT beam tube on IRT in Sofia
    Belousov, S.
    Ilieva, K.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S230 - S233
  • [2] Visualization of tritium distribution by autoradiography technique
    Zouev, YN
    Podgornova, IV
    Sagaragze, VV
    FUSION ENGINEERING AND DESIGN, 2000, 49-50 : 971 - 976
  • [3] Hyaluronic acid as a potential boron carrier for BNCT: Preliminary evaluation
    Zaboronok, A.
    Yamamoto, T.
    Nakai, K.
    Yoshida, F.
    Uspenskii, S.
    Selyanin, M.
    Zelenetskii, A.
    Matsumura, Akira
    APPLIED RADIATION AND ISOTOPES, 2015, 106 : 181 - 184
  • [4] Preliminary characterization of a CdZnTe photon detector for BNCT-SPECT
    Fatemi, S.
    Altieri, S.
    Bortolussi, S.
    Postuma, I
    Benassi, G.
    Zambelli, N.
    Bettelli, M.
    Zanichelli, M.
    Zappettini, A.
    Protti, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 903 : 134 - 139
  • [5] BNCT research facility at MARIA reactor - Numerical models and preliminary measurements
    Tyminska, K.
    Wojtania, G.
    Krzeminski, L.
    Talarowska, A.
    Maciak, M.
    Madejowski, G.
    Araszkiewicz, M.
    Wilinski, M.
    Kuc, M.
    Gryzinski, M. A.
    APPLIED RADIATION AND ISOTOPES, 2020, 166
  • [6] PhoNeS: A novel approach to BNCT with conventional radiotherapy accelerators
    Bevilacqua, R.
    Giannini, G.
    Calligaris, F.
    Fontanarosa, D.
    Longo, F.
    Scian, G.
    Totaro, P.
    Vittor, K.
    Vallazza, E.
    Severgnini, M.
    Vidimari, R.
    Bartesaghi, G.
    Conti, V.
    Mascagna, V.
    Perboni, C.
    Prest, M.
    Gambarini, G.
    Gay, S.
    Valente, M. A.
    Mozzanica, A.
    Monti, A.
    Ostinelli, A.
    Azario, L.
    Fidanzio, A.
    Piermattei, A.
    Borla, O.
    Durisi, Elisabetta
    Fasolo, F.
    Nastasi, U.
    Perosino, E.
    Zanini, A.
    Tommasino, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01) : 231 - 232
  • [7] A preliminary study on using the radiochromic film for 2D beam profile QC/QA at the THOR BNCT facility
    Hsiao, Ming-Chen
    Chen, Wei-Lin
    Tsai, Pi-En
    Huang, Chun-Kai
    Liu, Yuan-Hao
    Liu, Hong-Ming
    Jiang, Shiang-Huei
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1915 - 1917
  • [8] Whole-body autoradiography: An efficient technique to study copper accumulation and body distribution in small organisms
    Pinho, Grasiela L. L.
    Bianchini, Adalto
    Rouleau, Claude
    CHEMOSPHERE, 2011, 85 (01) : 1 - 6
  • [9] In-situ vacuum deposition technique of lithium on neutron production target for BNCT
    Ishiyama, S.
    Baba, Y.
    Fujii, R.
    Nakamura, M.
    Imahori, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 288 : 18 - 22
  • [10] AGATE Monte Carlo study on ICRP110 phantoms for BNCT dosimetry evaluation
    Pistone, Daniele
    Bortolussi, Silva
    Fatemi, Setareh
    Marcaccio, Barbara
    Bagnale, Laura
    Pezzi, Cristina
    Paganelli, Marco
    Ramos, Ricardo Luis
    Formicola, Emilia
    Sica, Rosa
    Buompane, Raffaele
    Porzio, Giuseppe
    Manti, Lorenzo
    Gialanella, Lucio
    Vercesi, Valerio
    Postuma, Ian
    APPLIED RADIATION AND ISOTOPES, 2025, 220