Ionic liquid-bonded polysiloxane as stationary phase for capillary gas chromatography

被引:31
|
作者
Sun, Xiaojie [1 ]
Wu, Caiying [1 ]
Xing, Jun [1 ]
机构
[1] Wuhan Univ, Coll Chem & Mol Sci, Minist Educ, Key Lab Analyt Chem Biol & Med, Wuhan 430072, Hubei, Peoples R China
关键词
Bonded; Gas chromatography; Ionic liquid; Polysiloxane; Stationary phase; OPEN-TUBULAR COLUMNS; SEPARATION CHARACTERISTICS; ENANTIOMERIC SEPARATIONS; TEMPERATURE; SELECTIVITY; COPOLYMERS; DIPHENYL; BEHAVIOR;
D O I
10.1002/jssc.201000030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ionic liquid (IL) stationary phase is especially suitable for separation of complex samples owing to the dual nature of IL In this study a synthetic method of ionic liquid bonded polysiloxane (PSOIL) as stationary phase of GC was proposed Then the PSOIL was used to prepare an 8 m capillary column by static method The column efficiency was measured to be about 4000 plates/m (k = 3 55 naphthalene) after the column had been conditioned at 210 C The durability of PSOIL column was better than that of the mixed stationary phase of IL and OV 1 Moreover the Abraham solvation parameter model was employed to characterize the PSOIL The result revealed that the PSOIL had stronger dispersion force (1) than neat IL and stronger hydrogen bond basicity (a) than DB 1 That meant the PSOIL might offer good selectivity for both polar and non polar analytes The column exhibited unique selectivity for various organic substances such as the homologous compounds of alkanes esters alcohols and aromatic compounds It was also found that some aromatic positional isomers could be separated better on the PSOIL column than on the DB 1 column Furthermore the stationary phase was suitable for separation of high boiling point compounds such as polycyclic aromatic hydrocarbons phthalic esters etc All of these demonstrated that the PSOIL offered good selectivity and high separation efficiency for a wide range of analytes
引用
收藏
页码:3159 / 3167
页数:9
相关论文
共 50 条
  • [1] Preparation of mixed stationary phase of cellulose an polysiloxane ionic liquid for gas chromatography
    Chen Gang
    Zhao Xiaojie
    Xing Jun
    Yao Yuhua
    Zheng Jingjing
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (10) : 1117 - 1123
  • [2] Novel Geminal Dicationic Ionic Liquid As Stationary Phase For Capillary Gas Chromatography
    Liu, Tao
    Zhang, Linxia
    Sun, Liquan
    Luo, Aiqin
    ADVANCED RESEARCH ON ADVANCED STRUCTURE, MATERIALS AND ENGINEERING, 2012, 382 : 477 - 480
  • [3] Polysiloxane with pendant [60]fulleropyrrolidines as stationary phase for capillary gas chromatography
    Liu, Y
    Zhang, XG
    Chen, YY
    Zeng, ZR
    Ye, HY
    Sheng, RS
    CHINESE CHEMICAL LETTERS, 1998, 9 (09) : 847 - 850
  • [4] Polysiloxane with Pendant [60]Fulleropyrrolidines as Stationary Phase for Capillary Gas Chromatography
    Ying LIU
    Xun Gao ZHANG
    Han Ying YE
    (Department of Analysis and Measurement Science
    Zhao Rui ZENG
    (Department of Chemistry
    Chinese Chemical Letters, 1998, (09) : 847 - 850
  • [5] [60] fulleropyrrolidine functionalized polysiloxane as a stationary phase for capillary gas chromatography
    Zeng, ZR
    Ye, HY
    Liu, Y
    Chen, YY
    CHROMATOGRAPHIA, 1999, 49 (5-6) : 293 - 298
  • [6] [60] Fulleropyrrolidine functionalized polysiloxane as a stationary phase for capillary gas chromatography
    Z. -R. Zeng
    H. -Y. Ye
    Y. Liu
    Y. -Y. Chen
    Chromatographia, 1999, 49 : 293 - 298
  • [7] Preparation and evaluation of a novel bonded imidazolium ionic liquid as stationary phase for gas chromatography
    Dai, Jia-Ling
    Zhao, Li-Hua
    Shi, Jie-Hua
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (13) : 2769 - 2778
  • [8] SMECTIC BIPHENYLCARBOXYLATE ESTER LIQUID-CRYSTALLINE POLYSILOXANE STATIONARY PHASE FOR CAPILLARY GAS-CHROMATOGRAPHY
    MARKIDES, KE
    NISHIOKA, M
    TARBET, BJ
    BRADSHAW, JS
    LEE, ML
    ANALYTICAL CHEMISTRY, 1985, 57 (07) : 1296 - 1299
  • [9] Evaluation of chromatographic performance of polymerized ionic liquid stationary phase for capillary gas chromatography
    Chen Xiaoyan
    Lu Kai
    Qi Meiling
    Fu Ruonong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (06) : 750 - 754
  • [10] Application of Quaternary Aminated β-cyclodextrin Ionic Liquid Stationary Phase in Capillary Gas Chromatography
    Zhang, Lin Xia
    Liu, Tao
    Luo, Ai Qin
    EQUIPMENT MANUFACTURING TECHNOLOGY AND AUTOMATION, PTS 1-3, 2011, 317-319 : 1936 - 1939