Refraction as imaging signal for computerized (neutron) tomography

被引:40
作者
Treimer, W
Strobl, M
Hilger, A
Seifert, C
Feye-Treimer, U
机构
[1] Univ Appl Sci TFH Berlin, FB 2, D-13353 Berlin, Germany
[2] Hahn Meitner Inst Berlin GmbH, D-14109 Berlin, Germany
关键词
D O I
10.1063/1.1591066
中图分类号
O59 [应用物理学];
学科分类号
摘要
Refraction of thermal neutrons was used as imaging signal for computerized neutron tomography. Using a special instrument, attenuation and refraction could be observed simultaneously, extracted and separated from each other, and two-dimensional (2D) images reconstructed from pure refraction data. Even in the case of no attenuation contrast, perfect 2D images of objects could be reconstructed using the refraction data only. (C) 2003 American Institute of Physics.
引用
收藏
页码:398 / 400
页数:3
相关论文
共 13 条
[1]   Imaging - Phase radiography with neutrons [J].
Allman, BE ;
McMahon, PJ ;
Nugent, KA ;
Paganin, D ;
Jacobson, DL ;
Arif, M ;
Werner, SA .
NATURE, 2000, 408 (6809) :158-159
[2]  
[Anonymous], 1999, BOOK
[3]   AN X-RAY INTERFEROMETER [J].
BONSE, U ;
HART, M .
APPLIED PHYSICS LETTERS, 1965, 6 (08) :155-&
[4]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[5]  
Herman G.T., 1980, COMPUTER SCI APPL MA
[6]   Design of a neutron radiography facility at the spallation source SINQ [J].
Lehmann, E ;
Pleinert, H ;
Wiezel, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (01) :11-15
[7]  
Podurets K. M., 1989, Soviet Physics - Technical Physics, V34, P654
[8]  
PODURETS KM, 1995, TECH PHYS, V40
[9]  
Schillinger B., 2001, NONDESTRUCTIVE TESTI, V16, P141
[10]  
Schillinger B., 1996, J. Neutron Res., V4, P57, DOI [10.1080/10238169608200068, DOI 10.1080/10238169608200068]