Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences

被引:32
作者
Kunz, RP
Oellig, F
Krummenauer, F
Oberholzer, K
Romaneehsen, B
Vomweg, TW
Horstick, G
Hayes, C
Thelen, M
Kreitner, KF
机构
[1] Univ Mainz, Dept Radiol, D-55131 Mainz, Germany
[2] Univ Mainz, Dept Biometry Epidemiol & Informat, D-55131 Mainz, Germany
[3] Univ Mainz, Dept Internal Med & Cardiol, D-55131 Mainz, Germany
[4] Siemens AG, Erlangen, Germany
关键词
magnetic resonance imaging; heart; steady-state imaging; real-time imaging; cardiac ventricular function;
D O I
10.1002/jmri.20230
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare steady-state free precession (SSFP) sequence protocols with different acquisition times (TA) and temporal resolutions (tRes) due to the implementation of a view sharing technique called shared phases for the assessment of left ventricular (LV) function by breath-hold cine magnetic resonance (MR) imaging. Materials and Methods: End-diastolic and end-systolic volumes (EDV, ESV) were measured in contiguous short-axis slices with a thickness of 8 mm acquired in 10 healthy male volunteers. The following true fast imaging with steady-state precession (TrueFISP) sequence protocols were compared: protocol A) internal standard of reference, segmented: tRes 34.5 msec, TA 18 beats per slice; protocol B) segmented, shared phases: tRes 34.1 msec, TA 10 beats per slice; and protocol Q real-time, shared phases, parallel acquisition technique: tRes 47.3 msec, TA 24 beats for 12 slices covering the entire left ventricle. Results: Phase sharing leads to a significant decrease in EDV, stroke volume (SV), and ejection fraction (EF) (median difference -7.0 mL [*], -9.6 mL, and -3.4%, respectively, for protocol B; -15.3 mL, -13.3 mL, and -2.4% for protocol C; P = 0.002, *P = 0.021). The observed median difference of real-time EDV and SV estimates is of clinical relevance. Real-time cine MR imaging shows a greater variability of EDV and SV. No relevant differences in ESV were observed. Conclusion: The true cine frame duration of both shared phases sequence protocols exceeds the period of isovolumetric contraction (IVCT) of the left ventricle resulting in a systematic and significant underestimation of EDV and consequently SV and EF. SSFP sequence protocol parameters, particularly tRes and use of view sharing techniques, should therefore be known at follow-up examinations in order to be able to assess LV remodeling in patients with heart failure.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 50 条
[41]   Cine Cardiac Imaging Using Black-Blood Steady-State Free Precession (BB-SSFP) at 3T [J].
Basha, Tamer A. ;
Ibrahim, El-Sayed H. ;
Weiss, Robert G. ;
Osman, Nael F. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (01) :94-103
[42]   Accuracy of Right and Left Ventricular Functional Assessment by Short-Axis vs Axial Cine Steady-State Free-Precession Magnetic Resonance Imaging: Intrapatient Correlation With Main Pulmonary Artery and Ascending Aorta Phase-Contrast Flow Measurements [J].
James, Susan H. ;
Wald, Rachel ;
Wintersperger, Bernd J. ;
Jimenez-Juan, Laura ;
Deva, Djeven ;
Crean, Andrew M. ;
Elsie Nguyen ;
Paul, Narinder S. ;
Ley, Sebastian .
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (03) :213-219
[43]   Functional cardiac MR imaging with true fast imaging with steady-state free precession before and after intravenous injection of contrast medium: comparison of image quality and accuracy [J].
Gabriele A. Krombach ;
Thorsten Plum ;
Ralf Koos ;
Rainer Hoffmann ;
Ertunc Altiok ;
Nils A. Krämer ;
Rolf W. Günther ;
Felix Schoth .
European Radiology, 2011, 21 :702-711
[44]   Simultaneous multislice steady-state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T [J].
McElroy, Sarah ;
Ferrazzi, Giulio ;
Nazir, Muhummad Sohaib ;
Evans, Carl ;
Ferreira, Joana ;
Bosio, Filippo ;
Mughal, Nabila ;
Kunze, Karl P. ;
Neji, Radhouene ;
Speier, Peter ;
Stab, Daniel ;
Ismail, Tevfik F. ;
Masci, Pier Giorgio ;
Villa, Adriana D. M. ;
Razavi, Reza ;
Chiribiri, Amedeo ;
Roujol, Sebastien .
MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (02) :663-675
[45]   Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold [J].
Tomoyuki Kido ;
Teruhito Kido ;
Masashi Nakamura ;
Kouki Watanabe ;
Michaela Schmidt ;
Christoph Forman ;
Teruhito Mochizuki .
Journal of Cardiovascular Magnetic Resonance, 18
[46]   Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold [J].
Kido, Tomoyuki ;
Kido, Teruhito ;
Nakamura, Masashi ;
Watanabe, Kouki ;
Schmidt, Michaela ;
Forman, Christoph ;
Mochizuki, Teruhito .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
[47]   Comparison of two single-breath-held 3-D acquisitions with multi-breath-held 2-D cine steady-state free precession MRI acquisition in children with single ventricles [J].
Lamya A. Atweh ;
Nicholas A. Dodd ;
Ramkumar Krishnamurthy ;
Amol Pednekar ;
Zili D. Chu ;
Rajesh Krishnamurthy .
Pediatric Radiology, 2016, 46 :637-645
[48]   Cine MR imaging after myocardial infarction - Assessment and follow-up of regional and global left ventricular function [J].
Sandstede, JJW ;
Lipke, C ;
Kenn, W ;
Beer, M ;
Pabst, T ;
Hahn, D .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1999, 15 (06) :435-440
[49]   Cine MR imaging after myocardial infarction – Assessment and follow-up of regional and global left ventricular function [J].
Joern J.W. Sandstede ;
Claudia Lipke ;
Werner Kenn ;
Meinrad Beer ;
Thomas Pabst ;
Dietbert Hahn .
The International Journal of Cardiac Imaging, 1999, 15 :435-440
[50]   Coronary MR imaging using free-breathing 3D steady-state free precession with radial k-space sampling [J].
Spuentrup, E ;
Katoh, M ;
Stuber, M ;
Botnar, R ;
Schaeffter, T ;
Buecker, A ;
Günther, RW .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (10) :1330-1334