Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences

被引:32
作者
Kunz, RP
Oellig, F
Krummenauer, F
Oberholzer, K
Romaneehsen, B
Vomweg, TW
Horstick, G
Hayes, C
Thelen, M
Kreitner, KF
机构
[1] Univ Mainz, Dept Radiol, D-55131 Mainz, Germany
[2] Univ Mainz, Dept Biometry Epidemiol & Informat, D-55131 Mainz, Germany
[3] Univ Mainz, Dept Internal Med & Cardiol, D-55131 Mainz, Germany
[4] Siemens AG, Erlangen, Germany
关键词
magnetic resonance imaging; heart; steady-state imaging; real-time imaging; cardiac ventricular function;
D O I
10.1002/jmri.20230
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare steady-state free precession (SSFP) sequence protocols with different acquisition times (TA) and temporal resolutions (tRes) due to the implementation of a view sharing technique called shared phases for the assessment of left ventricular (LV) function by breath-hold cine magnetic resonance (MR) imaging. Materials and Methods: End-diastolic and end-systolic volumes (EDV, ESV) were measured in contiguous short-axis slices with a thickness of 8 mm acquired in 10 healthy male volunteers. The following true fast imaging with steady-state precession (TrueFISP) sequence protocols were compared: protocol A) internal standard of reference, segmented: tRes 34.5 msec, TA 18 beats per slice; protocol B) segmented, shared phases: tRes 34.1 msec, TA 10 beats per slice; and protocol Q real-time, shared phases, parallel acquisition technique: tRes 47.3 msec, TA 24 beats for 12 slices covering the entire left ventricle. Results: Phase sharing leads to a significant decrease in EDV, stroke volume (SV), and ejection fraction (EF) (median difference -7.0 mL [*], -9.6 mL, and -3.4%, respectively, for protocol B; -15.3 mL, -13.3 mL, and -2.4% for protocol C; P = 0.002, *P = 0.021). The observed median difference of real-time EDV and SV estimates is of clinical relevance. Real-time cine MR imaging shows a greater variability of EDV and SV. No relevant differences in ESV were observed. Conclusion: The true cine frame duration of both shared phases sequence protocols exceeds the period of isovolumetric contraction (IVCT) of the left ventricle resulting in a systematic and significant underestimation of EDV and consequently SV and EF. SSFP sequence protocol parameters, particularly tRes and use of view sharing techniques, should therefore be known at follow-up examinations in order to be able to assess LV remodeling in patients with heart failure.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 50 条
[31]   Comparison of right ventricular volume measurement between segmented K-space gradient-echo and steady-state free precession magnetic resonance Imaging [J].
Alfakih, K ;
Thiele, H ;
Plein, S ;
Bainbridge, GJ ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (03) :253-258
[32]   Functional cardiac MR imaging with true fast imaging with steady-state free precession before and after intravenous injection of contrast medium: comparison of image quality and accuracy [J].
Krombach, Gabriele A. ;
Plum, Thorsten ;
Koos, Ralf ;
Hoffmann, Rainer ;
Altiok, Ertunc ;
Kraemer, Nils A. ;
Guenther, Rolf W. ;
Schoth, Felix .
EUROPEAN RADIOLOGY, 2011, 21 (04) :702-711
[33]   Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance [J].
Maceira, A. M. ;
Prasad, S. K. ;
Khan, M. ;
Pennell, D. J. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2006, 8 (03) :417-426
[34]   Comparison of two single-breath-held 3-D acquisitions with multi-breath-held 2-D cine steady-state free precession MRI acquisition in children with single ventricles [J].
Atweh, Lamya A. ;
Dodd, Nicholas A. ;
Krishnamurthy, Ramkumar ;
Pednekar, Amol ;
Chu, Zili D. ;
Krishnamurthy, Rajesh .
PEDIATRIC RADIOLOGY, 2016, 46 (05) :637-645
[35]   Mean Thoracic Aortic Wall Thickness Determination by Cine MRI with Steady-State Free Precession: Validation with Dark Blood Imaging [J].
Mensel, Birger ;
Kuehn, Jens-Peter ;
Schneider, Tobias ;
Quadrat, Alexander ;
Hegenscheid, Katrin .
ACADEMIC RADIOLOGY, 2013, 20 (08) :1004-1008
[36]   Range of ventricular dimensions and function by steady-state free precession cine MRI in repaired tetralogy of Fallot: Right ventricular outflow tract patch vs. conduit repair [J].
Samyn, Margaret M. ;
Powell, Andrew J. ;
Garg, Ruchira ;
Sena, Laureen ;
Geva, Tal .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) :934-940
[37]   Assessment of left ventricular function with steady-state-free-precession magnetic resonance imagingReference values and a comparison to left ventriculographyBestimmung der linksventrikulären Funktion mittels Steady-state-free-precession Magnetresonanztomographie: Referenzwerte und ein Vergleich zur Laevokardiographie [J].
O. Grebe ;
H. A. Kestler ;
N. Merkle ;
J. Wöhrle ;
M. Kochs ;
M. Höher ;
V. Hombach .
Zeitschrift für Kardiologie, 2004, 93 (9) :686-695
[38]   Free breathing 2D multi-slice real-time gradient-echo cardiovascular magnetic resonance imaging: impact on left ventricular function measurements compared with standard multi-breath hold 2D steady-state free precession imaging [J].
Sievers, Burkhard ;
Schrader, Sebastian ;
Hunold, Peter ;
Barkhausen, Joerg ;
Erbel, Raimund .
ACTA CARDIOLOGICA, 2011, 66 (04) :489-497
[39]   Diagnosis of Left Ventricular Diastolic Dysfunction Using Cardiac Magnetic Resonance Imaging: Comparison of Volume-Time Curves Derived from Long- and Short-Axis Cine Steady-State Free Precession Datasets [J].
Schaafs, Lars-Arne ;
Wyschkon, Sebastian ;
Elgeti, Matthias ;
Nagel, Sebastian Niko ;
Knebel, Fabian ;
Steffen, Ingo G. ;
Makowski, Marcus R. ;
Hamm, Bernd ;
Elgeti, Thomas .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2020, 192 (08) :764-775
[40]   Normal human left and right ventricular and left atrial dimensions using steady state free precession magnetic resonance imaging [J].
Hudsmith, LE ;
Petersen, SE ;
Francis, JM ;
Robson, MD ;
Neubauer, S .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (05) :775-782