Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences

被引:32
作者
Kunz, RP
Oellig, F
Krummenauer, F
Oberholzer, K
Romaneehsen, B
Vomweg, TW
Horstick, G
Hayes, C
Thelen, M
Kreitner, KF
机构
[1] Univ Mainz, Dept Radiol, D-55131 Mainz, Germany
[2] Univ Mainz, Dept Biometry Epidemiol & Informat, D-55131 Mainz, Germany
[3] Univ Mainz, Dept Internal Med & Cardiol, D-55131 Mainz, Germany
[4] Siemens AG, Erlangen, Germany
关键词
magnetic resonance imaging; heart; steady-state imaging; real-time imaging; cardiac ventricular function;
D O I
10.1002/jmri.20230
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare steady-state free precession (SSFP) sequence protocols with different acquisition times (TA) and temporal resolutions (tRes) due to the implementation of a view sharing technique called shared phases for the assessment of left ventricular (LV) function by breath-hold cine magnetic resonance (MR) imaging. Materials and Methods: End-diastolic and end-systolic volumes (EDV, ESV) were measured in contiguous short-axis slices with a thickness of 8 mm acquired in 10 healthy male volunteers. The following true fast imaging with steady-state precession (TrueFISP) sequence protocols were compared: protocol A) internal standard of reference, segmented: tRes 34.5 msec, TA 18 beats per slice; protocol B) segmented, shared phases: tRes 34.1 msec, TA 10 beats per slice; and protocol Q real-time, shared phases, parallel acquisition technique: tRes 47.3 msec, TA 24 beats for 12 slices covering the entire left ventricle. Results: Phase sharing leads to a significant decrease in EDV, stroke volume (SV), and ejection fraction (EF) (median difference -7.0 mL [*], -9.6 mL, and -3.4%, respectively, for protocol B; -15.3 mL, -13.3 mL, and -2.4% for protocol C; P = 0.002, *P = 0.021). The observed median difference of real-time EDV and SV estimates is of clinical relevance. Real-time cine MR imaging shows a greater variability of EDV and SV. No relevant differences in ESV were observed. Conclusion: The true cine frame duration of both shared phases sequence protocols exceeds the period of isovolumetric contraction (IVCT) of the left ventricle resulting in a systematic and significant underestimation of EDV and consequently SV and EF. SSFP sequence protocol parameters, particularly tRes and use of view sharing techniques, should therefore be known at follow-up examinations in order to be able to assess LV remodeling in patients with heart failure.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 50 条
  • [21] Comparison of a Multi-Breath-Hold and a Single Breath-Hold Cine Imaging Approach for 4D Guide-Point Modeling of the Left Ventricle
    Heilmaier, C.
    Schlosser, T.
    Bruder, O.
    Nassenstein, K.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (09): : 780 - 787
  • [22] Comparison of left and right ventricular ejection and filling parameters by fast cine MR imaging in breath-hold technique: Clinical study of 42 patients with cardiomyopathy and coronary heart disease.
    Rominger, MB
    Bachmann, GF
    Geuer, M
    Puzik, M
    Ricken, WW
    Rau, WS
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (06): : 534 - 541
  • [23] Single breath-hold compressed sensing real-time cine imaging to assess left ventricular motion in myocardial infarction
    Longere, Benjamin
    Chavent, Marc-Henry
    Coisne, Augustin
    Gkizas, Christos
    Pagniez, Julien
    Simeone, Arianna
    Silvestri, Valentina
    Schmidt, Michaela
    Forman, Christoph
    Montaigne, David
    Pontana, Francois
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (05) : 297 - 303
  • [24] Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precessiion
    Lee, VS
    Resnick, D
    Bundy, JM
    Simonetti, OP
    Lee, P
    Weinreb, JC
    RADIOLOGY, 2002, 222 (03) : 835 - 842
  • [25] GRADIENT MOMENT NULLING FOR STEADY-STATE FREE PRECESSION MR IMAGING OF CEREBROSPINAL-FLUID
    WOOD, ML
    ZUR, Y
    NEURINGER, LJ
    MEDICAL PHYSICS, 1991, 18 (05) : 1038 - 1044
  • [26] AUTOMATED MYOCARDIAL EDGE-DETECTION FROM BREATH-HOLD CINE-MR IMAGES - EVALUATION OF LEFT-VENTRICULAR VOLUMES AND MASS
    BALDY, C
    DOUEK, P
    CROISILLE, P
    MAGNIN, IE
    REVEL, D
    AMIEL, M
    MAGNETIC RESONANCE IMAGING, 1994, 12 (04) : 589 - 598
  • [27] Steady-state free precession magnetic resonance imaging of the heart: Comparison with segmented K-space gradient-echo imaging
    Plein, S
    Bloomer, TN
    Ridgway, JP
    Jones, TR
    Bainbridge, GJ
    Sivananthan, MU
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) : 230 - 236
  • [28] Use of compressed sensing to reduce scan time and breath-holding for cardiac cine balanced steady-state free precession magnetic resonance imaging in children and young adults
    Nivedita K. Naresh
    LaDonna Malone
    Takashi Fujiwara
    Sarah Smith
    Quin Lu
    Mark D. Twite
    Michael V. DiMaria
    Brian M. Fonseca
    Lorna P. Browne
    Alex J. Barker
    Pediatric Radiology, 2021, 51 : 1192 - 1201
  • [29] Real-time cardiac magnetic resonance cine imaging with sparse sampling and iterative reconstruction for left-ventricular measures: Comparison with gold-standard segmented steady-state free precession
    Camargo, Gabriel C.
    Erthal, Fernanda
    Sabioni, Leticia
    Penna, Filipe
    Strecker, Ralph
    Schmidt, Michaela
    Zenge, Michael O.
    Lima, Ronaldo de S. L.
    Gottlieb, Ilan
    MAGNETIC RESONANCE IMAGING, 2017, 38 : 138 - 144
  • [30] Use of compressed sensing to reduce scan time and breath-holding for cardiac cine balanced steady-state free precession magnetic resonance imaging in children and young adults
    Naresh, Nivedita K.
    Malone, LaDonna
    Fujiwara, Takashi
    Smith, Sarah
    Lu, Quin
    Twite, Mark D.
    DiMaria, Michael, V
    Fonseca, Brian M.
    Browne, Lorna P.
    Barker, Alex J.
    PEDIATRIC RADIOLOGY, 2021, 51 (07) : 1192 - 1201