Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences

被引:32
作者
Kunz, RP
Oellig, F
Krummenauer, F
Oberholzer, K
Romaneehsen, B
Vomweg, TW
Horstick, G
Hayes, C
Thelen, M
Kreitner, KF
机构
[1] Univ Mainz, Dept Radiol, D-55131 Mainz, Germany
[2] Univ Mainz, Dept Biometry Epidemiol & Informat, D-55131 Mainz, Germany
[3] Univ Mainz, Dept Internal Med & Cardiol, D-55131 Mainz, Germany
[4] Siemens AG, Erlangen, Germany
关键词
magnetic resonance imaging; heart; steady-state imaging; real-time imaging; cardiac ventricular function;
D O I
10.1002/jmri.20230
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare steady-state free precession (SSFP) sequence protocols with different acquisition times (TA) and temporal resolutions (tRes) due to the implementation of a view sharing technique called shared phases for the assessment of left ventricular (LV) function by breath-hold cine magnetic resonance (MR) imaging. Materials and Methods: End-diastolic and end-systolic volumes (EDV, ESV) were measured in contiguous short-axis slices with a thickness of 8 mm acquired in 10 healthy male volunteers. The following true fast imaging with steady-state precession (TrueFISP) sequence protocols were compared: protocol A) internal standard of reference, segmented: tRes 34.5 msec, TA 18 beats per slice; protocol B) segmented, shared phases: tRes 34.1 msec, TA 10 beats per slice; and protocol Q real-time, shared phases, parallel acquisition technique: tRes 47.3 msec, TA 24 beats for 12 slices covering the entire left ventricle. Results: Phase sharing leads to a significant decrease in EDV, stroke volume (SV), and ejection fraction (EF) (median difference -7.0 mL [*], -9.6 mL, and -3.4%, respectively, for protocol B; -15.3 mL, -13.3 mL, and -2.4% for protocol C; P = 0.002, *P = 0.021). The observed median difference of real-time EDV and SV estimates is of clinical relevance. Real-time cine MR imaging shows a greater variability of EDV and SV. No relevant differences in ESV were observed. Conclusion: The true cine frame duration of both shared phases sequence protocols exceeds the period of isovolumetric contraction (IVCT) of the left ventricle resulting in a systematic and significant underestimation of EDV and consequently SV and EF. SSFP sequence protocol parameters, particularly tRes and use of view sharing techniques, should therefore be known at follow-up examinations in order to be able to assess LV remodeling in patients with heart failure.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 35 条
[21]   The influence of through-plane motion on left ventricular volumes measured by magnetic resonance imaging:: Implications for image acquisition and analysis [J].
Marcus, JT ;
Götte, MJW ;
DeWaal, LK ;
Stam, MR ;
Van der Geest, RJ ;
Heethaar, RM ;
Van Rossum, AC .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 1999, 1 (01) :1-6
[22]   A PERSPECTIVE ON K-SPACE [J].
MEZRICH, R .
RADIOLOGY, 1995, 195 (02) :297-315
[23]   MR imaging of the heart with cine true fast imaging with steady-state precession: Influence of spatial and temporal resolutions on left ventricular functional parameters [J].
Miller, S ;
Simonetti, OP ;
Carr, J ;
Kramer, U ;
Finn, JP .
RADIOLOGY, 2002, 223 (01) :263-269
[24]   Breath-hold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility [J].
Moon, JCC ;
Lorenz, CH ;
Francis, JM ;
Smith, GC ;
Pennell, DJ .
RADIOLOGY, 2002, 223 (03) :789-797
[25]   Steady-state free precession magnetic resonance imaging of the heart: Comparison with segmented K-space gradient-echo imaging [J].
Plein, S ;
Bloomer, TN ;
Ridgway, JP ;
Jones, TR ;
Bainbridge, GJ ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :230-236
[26]  
Rominger MB, 1999, JMRI-J MAGN RESON IM, V10, P908
[27]  
Rominger MB, 1999, ROFO-FORTSCHR RONTG, V170, P54
[28]   EVALUATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH BREATH-HOLD CINE MR-IMAGING [J].
SAKUMA, H ;
FUJITA, N ;
FOO, TKF ;
CAPUTO, GR ;
NELSON, SJ ;
HARTIALA, J ;
SHIMAKAWA, A ;
HIGGINS, CB .
RADIOLOGY, 1993, 188 (02) :377-380
[29]   Age- and gender-specific differences in left and right ventricular cardiac function and mass determined by cine magnetic resonance imaging [J].
Sandstede, J ;
Lipke, C ;
Beer, M ;
Hofmann, S ;
Pabst, T ;
Kenn, W ;
Neubauer, S ;
Hahn, D .
EUROPEAN RADIOLOGY, 2000, 10 (03) :438-442
[30]   Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography [J].
Schalla, S ;
Nagel, E ;
Lehmkuhl, H ;
Klein, C ;
Bornstedt, A ;
Schnackenburg, B ;
Schneider, U ;
Fleck, E .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (01) :95-99