Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences

被引:32
作者
Kunz, RP
Oellig, F
Krummenauer, F
Oberholzer, K
Romaneehsen, B
Vomweg, TW
Horstick, G
Hayes, C
Thelen, M
Kreitner, KF
机构
[1] Univ Mainz, Dept Radiol, D-55131 Mainz, Germany
[2] Univ Mainz, Dept Biometry Epidemiol & Informat, D-55131 Mainz, Germany
[3] Univ Mainz, Dept Internal Med & Cardiol, D-55131 Mainz, Germany
[4] Siemens AG, Erlangen, Germany
关键词
magnetic resonance imaging; heart; steady-state imaging; real-time imaging; cardiac ventricular function;
D O I
10.1002/jmri.20230
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare steady-state free precession (SSFP) sequence protocols with different acquisition times (TA) and temporal resolutions (tRes) due to the implementation of a view sharing technique called shared phases for the assessment of left ventricular (LV) function by breath-hold cine magnetic resonance (MR) imaging. Materials and Methods: End-diastolic and end-systolic volumes (EDV, ESV) were measured in contiguous short-axis slices with a thickness of 8 mm acquired in 10 healthy male volunteers. The following true fast imaging with steady-state precession (TrueFISP) sequence protocols were compared: protocol A) internal standard of reference, segmented: tRes 34.5 msec, TA 18 beats per slice; protocol B) segmented, shared phases: tRes 34.1 msec, TA 10 beats per slice; and protocol Q real-time, shared phases, parallel acquisition technique: tRes 47.3 msec, TA 24 beats for 12 slices covering the entire left ventricle. Results: Phase sharing leads to a significant decrease in EDV, stroke volume (SV), and ejection fraction (EF) (median difference -7.0 mL [*], -9.6 mL, and -3.4%, respectively, for protocol B; -15.3 mL, -13.3 mL, and -2.4% for protocol C; P = 0.002, *P = 0.021). The observed median difference of real-time EDV and SV estimates is of clinical relevance. Real-time cine MR imaging shows a greater variability of EDV and SV. No relevant differences in ESV were observed. Conclusion: The true cine frame duration of both shared phases sequence protocols exceeds the period of isovolumetric contraction (IVCT) of the left ventricle resulting in a systematic and significant underestimation of EDV and consequently SV and EF. SSFP sequence protocol parameters, particularly tRes and use of view sharing techniques, should therefore be known at follow-up examinations in order to be able to assess LV remodeling in patients with heart failure.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 35 条
[1]   Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences [J].
Alfakih, K ;
Plein, S ;
Thiele, H ;
Jones, T ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :323-329
[2]   Assessment of ventricular function with single breath-hold real-time steady-state free precession cine MR Imaging [J].
Barkhausen, J ;
Goyen, M ;
Rühm, SG ;
Eggebrecht, H ;
Debatin, JF ;
Ladd, ME .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) :731-735
[3]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[4]   Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance [J].
Bellenger, NG ;
Davies, LC ;
Francis, JM ;
Coats, AJS ;
Pennell, DJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (04) :271-278
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Global cardiac function using fast breath-hold MRI: Validation of new acquisition and analysis techniques [J].
Bloomgarden, DC ;
Fayad, ZA ;
Ferrari, VA ;
Chin, B ;
Sutton, MGSJ ;
Axel, L .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) :683-692
[7]   Segmented K-space cine breath-hold cardiovascular MR imaging .1. Principles and technique [J].
Bluemke, DA ;
Boxerman, JL ;
Atalar, E ;
McVeigh, ER .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (02) :395-400
[8]   Multi-slice dynamic imaging: Complete functional cardiac MR examination within 15 seconds [J].
Bornstedt, A ;
Nagel, E ;
Schalla, S ;
Schnackenburg, B ;
Klein, C ;
Fleck, E .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :300-305
[9]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[10]   MR imaging of the heart in patients after myocardial infarction: Effect of increasing intersection gap on measurements of left ventricular volume, ejection fraction, and wall thickness [J].
Cottin, Y ;
Touzery, C ;
Guy, F ;
Lalande, A ;
Ressencourt, O ;
Roy, S ;
Walker, PM ;
Louis, P ;
Brunotte, F ;
Wolf, JE .
RADIOLOGY, 1999, 213 (02) :513-520