3-Dimensional Fluid and White Matter Suppression Magnetic Resonance Imaging Sequence Accelerated With Compressed Sensing Improves Multiple Sclerosis Cervical Spinal Cord Lesion Detection Compared With Standard 2-Dimensional Imaging

被引:3
|
作者
Emorine, Thibaut [1 ]
Megdiche, Imen [1 ]
Brugieres, Pierre [1 ]
Creange, Alain [2 ,3 ]
Kober, Tobias [4 ,5 ,6 ,7 ]
Massire, Aurelien [8 ]
Bapst, Blanche [1 ,3 ]
机构
[1] Henri Mondor Univ Hosp, AP HP, Dept Neuroradiol, Creteil, France
[2] Henri Mondor Univ Hosp, AP HP, Dept Neurol, Creteil, France
[3] Univ Paris Est Creteil, EA 4391, Creteil, France
[4] Siemens Healthcare AG, Adv Clin Imaging Technol, Lausanne, Switzerland
[5] Lausanne Univ Hosp, Dept Radiol, Lausanne, Switzerland
[6] Univ Lausanne, Lausanne, Switzerland
[7] Ecole Polytech Fed Lausanne EPFL, Signal Proc Lab LTS 5, Lausanne, Switzerland
[8] Siemens Healthcare SAS, St Denis, France
关键词
neuroradiology; multiple sclerosis; fluid and white matter suppression; cervical spinal cord; compressed sensing; MRI; DIAGNOSIS; RECOMMENDATIONS; SENSITIVITY; ACQUISITION; INVOLVEMENT; CONTRAST; CRITERIA; BRAIN; T1;
D O I
10.1097/RLI.0000000000000874
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Fluid and white matter suppression (FLAWS) is a recently proposed magnetic resonance sequence derived from magnetization-prepared 2 rapid acquisition gradient-echo providing 2 coregistered datasets with white matter- and cerebrospinal fluid-suppressed signal, enabling synthetic imaging with amplified contrast. Although these features are high potential for brain multiple sclerosis (MS) imaging, spinal cord has never been evaluated with this sequence to date. The objective of this work was therefore to assess diagnostic performance and self-confidence provided by compressed-sensing (CS) 3-dimensional (3D) FLAWS for cervical MS lesion detection on a head scan that includes the cervical cord without changing standard procedures. Materials and Methods Prospective 3 T scans (MS first diagnosis or follow-up) acquired between 2019 and 2020 were retrospectively analyzed. All patients underwent 3D CS-FLAWS (duration: 5 minutes 40 seconds), axial T-2 turbo spin echo covering cervical spine from cervicomedullary junction to the same inferior level as FLAWS, and sagittal cervical T-2/short tau inversion recovery imaging. Two readers performed a 2-stage double-blind reading, followed by consensus reading. Wilcoxon tests were used to compare the number of detected spinal cord lesions and the reader's diagnostic self-confidence when using FLAWS versus the reference 2D T-2-weighted imaging. Results Fifty-eight patients were included (mean age, 40 +/- 13 years, 46 women, 7 +/- 6 years mean disease duration). The CS-FLAWS detected significantly more lesions than the reference T-2-weighted imaging (197 vs 152 detected lesions, P < 0.001), with a sensitivity of 98% (T-2-weighted imaging sensitivity: 90%) after consensual reading. Considering the subgroup of patients who underwent sagittal T2 + short tau inversion recovery imaging (Magnetic Resonance Imaging for Multiple Sclerosis subgroup), +250% lesions were detected with FLAWS (63 vs 25 lesions detected, P < 0.001). Mean reading self-confidence was significantly better with CS-FLAWS (median, 5 [interquartile range, 1] [no doubt for diagnosis] vs 4 [interquartile range, 1] [high confidence]; P < 0.001). Conclusions Imaging with CS-FLAWS provides an improved cervical spinal cord exploration for MS with increased self-confidence compared with conventional T-2-weighted imaging, in a clinically acceptable time.
引用
收藏
页码:575 / 584
页数:10
相关论文
共 7 条
  • [1] Fluid and White Matter Suppression New Sensitive 3 T Magnetic Resonance Imaging Contrasts for Cortical Lesion Detection in Multiple Sclerosis
    Muller, Jannis
    La Rosa, Francesco
    Beaumont, Jeremy
    Tsagkas, Charidimos
    Rahmanzadeh, Reza
    Weigel, Matthias
    Bach Cuadra, Meritxell
    Gambarota, Giulio
    Granziera, Cristina
    INVESTIGATIVE RADIOLOGY, 2022, 57 (09) : 592 - 600
  • [2] Accelerated Internal Auditory Canal Screening Magnetic Resonance Imaging Protocol With Compressed Sensing 3-Dimensional T2-Weighted Sequence
    Yuhasz, Mikell
    Hoch, Michael J.
    Hagiwara, Mari
    Bruno, Mary T.
    Babb, James S.
    Raithel, Esther
    Forman, Christoph
    Anwar, Abbas
    Roland, J. Thomas, Jr.
    Shepherd, Timothy M.
    INVESTIGATIVE RADIOLOGY, 2018, 53 (12) : 742 - 747
  • [3] Multiple Sclerosis&IT Improved Detection of Active Cerebral Lesions With 3-Dimensional T1 Black-Blood Magnetic Resonance Imaging Compared With Conventional 3-Dimensional T1 GRE Imaging&IT
    Sommer, Nora N.
    Saam, Tobias
    Coppenrath, Eva
    Kooijman, Hendrik
    Kumpfel, Tania
    Patzig, Maximilian
    Beyer, Sebastian E.
    Sommer, Wieland H.
    Reiser, Maximilian F.
    Ertl-Wagner, Birgit
    Treitl, Karla M.
    INVESTIGATIVE RADIOLOGY, 2018, 53 (01) : 13 - 19
  • [4] 3D-Fast Gray Matter Acquisition with Phase Sensitive Inversion Recovery Magnetic Resonance Imaging at 3 Tesla: Application for detection of spinal cord lesions in patients with multiple sclerosis
    Goujon, Adrien
    Mirafzal, Sonia
    Zuber, Kevin
    Deschamps, Romain
    Sadik, Jean-Claude
    Gout, Olivier
    Savatovsky, Julien
    Lecler, Augustin
    PLOS ONE, 2021, 16 (04):
  • [5] Focal Liver Lesions: Real-time 3-Dimensional Contrast-Enhanced Ultrasonography Compared With 2-Dimensional Contrast-Enhanced Ultrasonography and Magnetic Resonance Imaging
    Lee, Jung-chieh
    Yan, Kun
    Lee, San-kan
    Yang, Wei
    Chen, Min-hua
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (10) : 2015 - 2026
  • [6] Contrast-enhanced Magnetic Resonance Imaging of Pelvic Bone Metastases at 3.0 T: Comparison Between 3-dimensional T1-weighted CAIPIRINHA-VIBE Sequence and 2-dimensional T1-weighted Turbo Spin-Echo Sequence
    Yoon, Min A.
    Hong, Suk-Joo
    Lee, Kyu-Chong
    Lee, Chang Hee
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (01) : 46 - 50
  • [7] Cortical and Subcortical Morphometric and Iron Changes in Relapsing-Remitting Multiple Sclerosis and Their Association with White Matter T2Lesion Load: A3-Tesla Magnetic Resonance Imaging Study
    Al-Radaideh, Ali
    Athamneh, Imad
    Alabadi, Hadeel
    Hbahbih, Majed
    CLINICAL NEURORADIOLOGY, 2019, 29 (01) : 51 - 64