Relationship between the Axillary Nerve and Accompanying Vessels and Proximal Humeral Locking Plates in Japanese: An MRI Study

被引:0
作者
Sakoma, Yoshimasa [1 ]
Hirooka, Takahiko [1 ]
机构
[1] Onomichi Municipal Hosp, Dept Orthopaed Surg, Onomichi, Hiroshima 7228503, Japan
关键词
proximal humeral fracture; locking plate; axillary nerve; posterior circumflex humeral artery; shoulder; FRACTURES; SHOULDER;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We investigated the anatomical features of the axillary nerve and its accompanying vessels with respect to the lateral wall of the greater tuberosity, focusing on the relationship between the neurovascular bundle and the proximal humeral locking plates. Magnetic resonance images of 30 Japanese patients' shoulders were examined. Oblique sagittal images across the greater tuberosity and the neurovascular bundle, which contain the axillary nerve and posterior circumflex humeral artery and vein, were obtained. The distance between the superior aspect of the greater tuberosity and the superior and inferior borders of the neurovascular bundles was measured at the anterior, middle, and posterior edges of the greater tuberosity. The neurovascular bundle was 28.5-36.7 mm, 32.6-41.3 mm, and 38.1-47.5 mm distal to the superior aspect of the greater tuberosity at the anterior, middle, and posterior edges, respectively. We evaluated the relationship between the neurovascular bundle and 3 different locking plates, which were placed at the lateral aspect of the greater tuberosity. Only 3 or four locking screws at the most proximal part could be safely inserted without axillary nerve interference.
引用
收藏
页码:525 / 529
页数:5
相关论文
共 22 条
[11]   Cross-elements to enhance fixation in osteoporotic bone with application to proximal humeral locking plates: a biomechanical study [J].
Gonzalez-Hernandez, Eduardo ;
Pietrzak, William S. ;
Jain, Saaransh ;
Lapica, Hans E. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (08) :1606-1614
[12]   Use of the Humeral Head as a Reference Point to Prevent Axillary Nerve Damage during Proximal Fixation of Humeral Fractures: An Anatomical and Radiographic Study [J].
Theeuwes, H. P. ;
Potters, J. W. ;
Bessems, J. H. J. M. ;
Kerver, A. J. ;
Kleinrensink, G. J. .
STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2020, 15 (02) :63-68
[13]   Serial changes in the head-shaft angle of proximal humeral fractures treated by placing locking plates: a retrospective study [J].
Ji-Qi Wang ;
Bing-Jie Jiang ;
Wei-Jun Guo ;
You-Ming Zhao .
BMC Musculoskeletal Disorders, 19
[14]   Serial changes in the head-shaft angle of proximal humeral fractures treated by placing locking plates: a retrospective study [J].
Wang, Ji-Qi ;
Jiang, Bing-Jie ;
Guo, Wei-Jun ;
Zhao, You-Ming .
BMC MUSCULOSKELETAL DISORDERS, 2018, 19
[15]   Comparison of the clinical outcomes and radiological parameters between the greater tuberosity strengthened proximal humeral plate and the proximal humeral internal locking system plate in the minimally invasive plate osteosynthesis treatment of proximal humeral fractures involving the greater tuberosity: a retrospective cohort study [J].
Le, Jiadi ;
Lu, Jianpeng ;
Zhang, Jianxiong ;
Wu, Zhenghao ;
Chen, Long .
BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
[16]   Comparison of CFR-PEEK and conventional titanium locking plates for proximal humeral fractures: a retrospective controlled study of patient outcomes [J].
Padolino A. ;
Porcellini G. ;
Guollo B. ;
Fabbri E. ;
Kiran Kumar G.N. ;
Paladini P. ;
Merolla G. .
MUSCULOSKELETAL SURGERY, 2018, 102 (Suppl 1) :49-56
[17]   Anatomic study of the axillary nerve in a Chinese cadaveric population: correlation of the course of the nerve with proximal humeral fixation with intramedullary nail or external skeletal fixation [J].
Kuang-Yi Liu ;
Tien-Hua Chen ;
Jia-Fwu Shyu ;
Shih-Tien Wang ;
Jenn-Yuan Liu ;
Po-Hsin Chou .
Archives of Orthopaedic and Trauma Surgery, 2011, 131 :669-674
[18]   Anatomic study of the axillary nerve in a Chinese cadaveric population: correlation of the course of the nerve with proximal humeral fixation with intramedullary nail or external skeletal fixation [J].
Liu, Kuang-Yi ;
Chen, Tien-Hua ;
Shyu, Jia-Fwu ;
Wang, Shih-Tien ;
Liu, Jenn-Yuan ;
Chou, Po-Hsin .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (05) :669-674
[19]   Versorgung von HumeruskopffrakturenLagebeziehung proximaler Verriegelungsplatten zum N. axillaris Treatment of proximal humerus fracturesRelative position of different locking plates to the axillary nerve [J].
J. Ninck ;
S. Heck ;
S. Gick ;
J. Koebke ;
D. Pennig ;
J. Dargel .
Der Unfallchirurg, 2013, 116 :1000-1005
[20]   Comparison of two different locking plates for two-, three- and four-part proximal humeral fractures—results of an international multicentre study [J].
Gerhard Konrad ;
Anja Hirschmüller ;
Laurent Audige ;
Simon Lambert ;
Ralf Hertel ;
Norbert P. Südkamp .
International Orthopaedics, 2012, 36 :1051-1058