Relationship between the Axillary Nerve and Accompanying Vessels and Proximal Humeral Locking Plates in Japanese: An MRI Study

被引:0
|
作者
Sakoma, Yoshimasa [1 ]
Hirooka, Takahiko [1 ]
机构
[1] Onomichi Municipal Hosp, Dept Orthopaed Surg, Onomichi, Hiroshima 7228503, Japan
关键词
proximal humeral fracture; locking plate; axillary nerve; posterior circumflex humeral artery; shoulder; FRACTURES; SHOULDER;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We investigated the anatomical features of the axillary nerve and its accompanying vessels with respect to the lateral wall of the greater tuberosity, focusing on the relationship between the neurovascular bundle and the proximal humeral locking plates. Magnetic resonance images of 30 Japanese patients' shoulders were examined. Oblique sagittal images across the greater tuberosity and the neurovascular bundle, which contain the axillary nerve and posterior circumflex humeral artery and vein, were obtained. The distance between the superior aspect of the greater tuberosity and the superior and inferior borders of the neurovascular bundles was measured at the anterior, middle, and posterior edges of the greater tuberosity. The neurovascular bundle was 28.5-36.7 mm, 32.6-41.3 mm, and 38.1-47.5 mm distal to the superior aspect of the greater tuberosity at the anterior, middle, and posterior edges, respectively. We evaluated the relationship between the neurovascular bundle and 3 different locking plates, which were placed at the lateral aspect of the greater tuberosity. Only 3 or four locking screws at the most proximal part could be safely inserted without axillary nerve interference.
引用
收藏
页码:525 / 529
页数:5
相关论文
共 22 条
  • [1] Relationship between axillary nerve and percutaneously inserted proximal humeral locking plate: a cadaver study
    Esenyel, Cem Zeki
    Dedeoglu, Semih
    Imren, Yunus
    Kahraman, Sinan
    Cakar, Murat
    Ozturk, Kahraman
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (05) : 553 - 557
  • [2] The outcome of surgical management of proximal humeral fractures using locking plates: comparison between Locking plates with different geometry
    Chen, Jiun-Liang
    Chang, Fu-Chun
    Lin, Shih-Jie
    Chuang, Po-Yao
    Peng, Kuo-Ti
    Huang, Kuo-Chin
    Huang, Tsan-Wen
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (12) : 2159 - 2166
  • [3] Axillary nerve damage in proximal humeral fractures: Clinical and electromyographic study
    Blas Dobon, J. A.
    Rodrigo Perez, J. L.
    Montaner Alonso, D.
    Escudero Torrella, M.
    TRAUMA-SPAIN, 2011, 22 (02): : 74 - 78
  • [4] Relationship of the axillary nerve to the proximal screws of a flexible humeral nail system: An anatomic study
    Albritton, MJ
    Barnes, CJ
    Basamania, CJ
    Karas, SG
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (06) : 411 - 414
  • [5] Comparative study between locking plates versus proximal humeral nail for the treatment of 2-part proximal humeral fractures
    Anna Domingo Trepat
    Dragos Popescu
    Jenaro Angel Fernández-Valencia
    Jordi Cuñé
    Moises Rios
    Salvi Prat
    European Journal of Orthopaedic Surgery & Traumatology, 2012, 22 : 373 - 379
  • [6] Comparative study between locking plates versus proximal humeral nail for the treatment of 2-part proximal humeral fractures
    Domingo Trepat, Anna
    Popescu, Dragos
    Angel Fernandez-Valencia, Jenaro
    Cune, Jordi
    Rios, Moises
    Prat, Salvi
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2012, 22 (05) : 373 - 379
  • [7] The relationship of proximal locking screws to the axillary nerve during antegrade humeral nail insertion of four commercially available implants
    Prince, EJ
    Breien, KM
    Fehringer, EV
    Mormino, MA
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (09) : 585 - 588
  • [8] Treatment of proximal humerus fractures. Relative position of different locking plates to the axillary nerve
    Ninck, J.
    Heck, S.
    Gick, S.
    Koebke, J.
    Pennig, D.
    Dargel, J.
    UNFALLCHIRURG, 2013, 116 (11): : 1000 - 1005
  • [9] Axillary nerve elongation in humeral fracture plating: A cadaveric study for comparison between straight and helical Philos plates
    Dauwe, Jan
    Grechenig, Peter
    Unterfrauner, Ines
    Schwarz, Angelika
    Weiglein, Andreas
    Hohenberger, Gloria
    JOURNAL OF ORTHOPAEDICS, 2020, 19 : 233 - 236
  • [10] Risk of injury to the axillary nerve during antegrade proximal humeral blade nail fixation - An anatomical study
    Spiegelberg, Ben G. I.
    Riley, Nicholas D.
    Taylor, Geoffrey J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (08): : 1185 - 1189