Effects of Daily Activities on Dual-Energy X-ray Absorptiometry Measurements of Body Composition in Active People

被引:139
作者
Nana, Alisa [1 ,2 ]
Slater, Gary J. [3 ]
Hopkins, Will G. [4 ]
Burke, Louise M. [1 ]
机构
[1] Australian Inst Sport, AIS Sports Nutr, Canberra, ACT, Australia
[2] RMIT Univ, Exercise Metab Grp, Bundoora, Vic, Australia
[3] Univ Sunshine Coast, Maroochydore, Qld, Australia
[4] Auckland Univ Technol, Auckland, New Zealand
关键词
DXA; LEAN MASS; BODY FAT; RELIABILITY; ATHLETES; FOOTBALL SOCCER PLAYERS; SOFT-TISSUE COMPOSITION; FAT MEASUREMENT; SPORTS-MEDICINE; MINERAL-CONTENT; BONE-DENSITY; DXA; MODEL; VALIDATION; PERFORMANCE;
D O I
10.1249/MSS.0b013e318228b60e
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
NANA, A., G. J. SLATER, W. G. HOPKINS, and L. M. BURKE. Effects of Daily Activities on Dual-Energy X-ray Absorptiometry Measurements of Body Composition in Active People. Med. Sci. Sports Exerc., Vol. 44, No. 1, pp. 180-189, 2012. Purpose: Dual-energy x-ray absorptiometry (DXA) is becoming a popular tool to measure body composition in athletes, owing to its ease of operation and comprehensive analysis of body composition. This study represents the first systematic investigation of the reliability of DXA measurements of body composition in trained individuals and includes measurements of daily variability as well as the specific effect of the intake of a meal. Methods: Physically active young adults (15 females, 16 males) underwent five whole-body DXA scans during a 2-d period: in the morning after an overnight fast, similar to 5 min later after repositioning on the scanning bed, similar to 8 h later after usual daily activities, and the next morning before and similar to 30 min after consumption of a simple breakfast. Magnitudes of typical (standard) errors of measurement and changes in the mean of DXA measures were assessed by standardization. Results: Repositioning produced trivial typical errors for whole-body composition, whereas regional body composition showed substantial errors. Daily activities and consumption of breakfast generally produced a substantial increase in the typical error and mean of DXA estimates of total and regional lean mass and associated body mass. Conclusions: Having a standardized scanning protocol and fasted subjects is the most practical way to minimize measurement errors. Future studies involving DXA in measuring body composition should report their scanning and analysis protocol with their associated typical errors of measurement so that the level of reliability can be assessed.
引用
收藏
页码:180 / 189
页数:10
相关论文
共 50 条
  • [41] Measures of body composition via Dual-energy X-ray absorptiometry, ultrasound and skinfolds are not impacted by the menstrual cycle in active eumenorrheic females
    Ong, Jun N.
    Ducker, Kagan J.
    Furzer, Bonnie J.
    Dymock, Michael
    Landers, Grant J.
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2022, 25 (02) : 115 - 121
  • [42] Repeatability and reproducibility of measurements obtained by dual-energy X-ray absorptiometry on pig carcasses
    Kipper, M.
    Marcoux, M.
    Andretta, I.
    Pomar, C.
    JOURNAL OF ANIMAL SCIENCE, 2018, 96 (05) : 2027 - 2037
  • [43] Comparison of Body Composition by Bioelectrical Impedance and Dual-Energy X-Ray Absorptiometry in Overweight/Obese Postmenopausal Women
    Fakhrawi, Dina H.
    Beeson, Lawrence
    Libanati, Cesar
    Feleke, Daniel
    Kim, Hannah
    Quansah, Alfred
    Darnell, Allan
    Lammi-Keefe, Carol J.
    Cordero-MacIntyre, Zaida
    JOURNAL OF CLINICAL DENSITOMETRY, 2009, 12 (02) : 238 - 244
  • [44] Body Composition at 6 months of Life: Comparison Of Air Displacement Plethysmography and Dual-Energy X-Ray Absorptiometry
    Fields, David A.
    Demerath, Ellen W.
    Pietrobelli, Angelo
    Chandler-Laney, Paula C.
    OBESITY, 2012, 20 (11) : 2302 - 2306
  • [45] Assessing body composition in taller or broader individuals using dual-energy X-ray absorptiometry: a systematic review
    Silva, A. M.
    Heymsfield, S. B.
    Sardinha, L. B.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 (10) : 1012 - 1021
  • [46] Body composition measured by dual-energy X-ray absorptiometry half-body scans in obese children
    Breithaupt, P.
    Colley, R. C.
    Adamo, K. B.
    ACTA PAEDIATRICA, 2011, 100 (12) : E260 - E266
  • [47] Body Composition Measured by Dual-energy X-ray Absorptiometry Half-body Scans in Obese Adults
    Rothney, Megan P.
    Brychta, Robert J.
    Schaefer, Emily V.
    Chen, Kong Y.
    Skarulis, Monica C.
    OBESITY, 2009, 17 (06) : 1281 - 1286
  • [48] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [49] Precision of Dual-Energy X-Ray Absorptiometry Reflection Scans in Muscular Athletes
    Tinsley, Grant M.
    Moore, Michael Lane
    Graybeal, Austin J.
    JOURNAL OF CLINICAL DENSITOMETRY, 2020, 23 (04) : 647 - 655
  • [50] Reliability of Lateral Distal Femur Dual-Energy X-Ray Absorptiometry Measures
    Mueske, Nicole M.
    Chan, Linda S.
    Wren, Tishya A. L.
    JOURNAL OF CLINICAL DENSITOMETRY, 2014, 17 (04) : 522 - 527