Effects of Daily Activities on Dual-Energy X-ray Absorptiometry Measurements of Body Composition in Active People

被引:139
作者
Nana, Alisa [1 ,2 ]
Slater, Gary J. [3 ]
Hopkins, Will G. [4 ]
Burke, Louise M. [1 ]
机构
[1] Australian Inst Sport, AIS Sports Nutr, Canberra, ACT, Australia
[2] RMIT Univ, Exercise Metab Grp, Bundoora, Vic, Australia
[3] Univ Sunshine Coast, Maroochydore, Qld, Australia
[4] Auckland Univ Technol, Auckland, New Zealand
关键词
DXA; LEAN MASS; BODY FAT; RELIABILITY; ATHLETES; FOOTBALL SOCCER PLAYERS; SOFT-TISSUE COMPOSITION; FAT MEASUREMENT; SPORTS-MEDICINE; MINERAL-CONTENT; BONE-DENSITY; DXA; MODEL; VALIDATION; PERFORMANCE;
D O I
10.1249/MSS.0b013e318228b60e
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
NANA, A., G. J. SLATER, W. G. HOPKINS, and L. M. BURKE. Effects of Daily Activities on Dual-Energy X-ray Absorptiometry Measurements of Body Composition in Active People. Med. Sci. Sports Exerc., Vol. 44, No. 1, pp. 180-189, 2012. Purpose: Dual-energy x-ray absorptiometry (DXA) is becoming a popular tool to measure body composition in athletes, owing to its ease of operation and comprehensive analysis of body composition. This study represents the first systematic investigation of the reliability of DXA measurements of body composition in trained individuals and includes measurements of daily variability as well as the specific effect of the intake of a meal. Methods: Physically active young adults (15 females, 16 males) underwent five whole-body DXA scans during a 2-d period: in the morning after an overnight fast, similar to 5 min later after repositioning on the scanning bed, similar to 8 h later after usual daily activities, and the next morning before and similar to 30 min after consumption of a simple breakfast. Magnitudes of typical (standard) errors of measurement and changes in the mean of DXA measures were assessed by standardization. Results: Repositioning produced trivial typical errors for whole-body composition, whereas regional body composition showed substantial errors. Daily activities and consumption of breakfast generally produced a substantial increase in the typical error and mean of DXA estimates of total and regional lean mass and associated body mass. Conclusions: Having a standardized scanning protocol and fasted subjects is the most practical way to minimize measurement errors. Future studies involving DXA in measuring body composition should report their scanning and analysis protocol with their associated typical errors of measurement so that the level of reliability can be assessed.
引用
收藏
页码:180 / 189
页数:10
相关论文
共 50 条
  • [31] Agreement between supine and standing bioimpedance spectroscopy devices and dual-energy X-ray absorptiometry for body composition determination
    Esco, Michael R.
    Fedewa, Michael V.
    Freeborn, Todd J.
    Moon, Jordan R.
    Wingo, Jonathan E.
    Cicone, Zack
    Holmes, Clifton J.
    Hornikel, Bjoern
    Welborn, Bailey
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2019, 39 (05) : 355 - 361
  • [32] Assessment of body composition in Indian adults: comparison between dual-energy X-ray absorptiometry and isotope dilution technique
    Kulkarni, Bharati
    Kuper, Hannah
    Taylor, Amy
    Wells, Jonathan C.
    Radhakrishna, K. V.
    Kinra, Sanjay
    Ben-Shlomo, Yoav
    Smith, George Davey
    Ebrahim, Shah
    Kurpad, A. V.
    Byrne, Nuala M.
    Hills, Andrew P.
    BRITISH JOURNAL OF NUTRITION, 2014, 112 (07) : 1147 - 1153
  • [33] Precision and accuracy of dual-energy X-ray absorptiometry for determining in vivo body composition of mice
    Nagy, TR
    Clair, AL
    OBESITY RESEARCH, 2000, 8 (05): : 392 - 398
  • [34] Within-subject variability in body composition using dual-energy X-ray absorptiometry
    DeLorenzo, A
    Andreoli, A
    Candeloro, N
    CLINICAL PHYSIOLOGY, 1997, 17 (04): : 383 - 388
  • [35] Obesity Increases Precision Errors in Total Body Dual-Energy X-Ray Absorptiometry Measurements
    Knapp, Karen M.
    Welsman, Joanne R.
    Hopkins, Susan J.
    Shallcross, Andrew
    Fogelman, Ignac
    Blake, Glen M.
    JOURNAL OF CLINICAL DENSITOMETRY, 2015, 18 (02) : 209 - 216
  • [36] PREDICTION OF BODY-COMPOSITION IN PREMENOPAUSAL FEMALES FROM DUAL-ENERGY X-RAY ABSORPTIOMETRY
    HANSEN, NJ
    LOHMAN, TG
    GOING, SB
    HALL, MC
    PAMENTER, RW
    BARE, LA
    BOYDEN, TW
    HOUTKOOPER, LB
    JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (04) : 1637 - 1641
  • [37] Body composition, dual-energy X-ray absorptiometry and obesity: the paradigm of fat (re)distribution
    Ponti, Federico
    Plazzi, Andrea
    Guglielmi, Giuseppe
    Marchesini, Giulio
    Bazzocchi, Alberto
    BJR CASE REPORTS, 2019, 5 (03):
  • [38] DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENTS OF BODY-COMPOSITION - EFFECTS OF DEPTH AND TISSUE THICKNESS, INCLUDING COMPARISONS WITH DIRECT ANALYSIS
    JEBB, SA
    GOLDBERG, GR
    JENNINGS, G
    ELIA, M
    CLINICAL SCIENCE, 1995, 88 (03) : 319 - 324
  • [39] Preclinical validation of automated dual-energy X-ray absorptiometry and computed tomography-based body composition measurements
    Devriese, Joke
    Beels, Laurence
    Van de Wiele, Christophe
    Maes, Alex
    Gheysens, Olivier
    Pottel, Hans
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 60 (01) : 40 - 47
  • [40] Repeatability and reproducibility of measurements obtained by dual-energy X-ray absorptiometry on pig carcasses
    Kipper, M.
    Marcoux, M.
    Andretta, I.
    Pomar, C.
    JOURNAL OF ANIMAL SCIENCE, 2018, 96 (05) : 2027 - 2037