Full-range Fourier domain optical coherence tomography imaging probe with a magnetic-driven resonant fiber cantilever

被引:12
作者
Zhang, Kang [1 ]
Huang, Yong [2 ]
Kang, Jin U. [2 ]
机构
[1] Gen Elect Global Res Ctr, Niskayuna, NY 12309 USA
[2] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
关键词
full-range optical coherence tomography; forward-viewing imaging probe; phase modulation; GRAPHICS PROCESSING UNIT; MEMS SCANNING CATHETER; HIGH-SPEED; ULTRAHIGH-RESOLUTION; SWEPT LASER; OCT; ENDOSCOPE; MICROSURGERY; ACTUATOR; SCANS;
D O I
10.1117/1.3645088
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this work, we developed a full-range Fourier domain optical coherence tomography (FD-OCT) imaging probe with a magnetic-driven resonant fiber cantilever. A galvanometer-driven reference mirror provides a linear phase modulation to each M-scan/B-scan frame to enable complex conjugate-free, full-range FD-OCT imaging. A fiber cantilever inside the probe is driven by a low-voltage miniature magnetic transducer. The fiber cantilever scans at its resonant frequency synchronized to the phase modulation induced by the reference mirror. Using a CCD line-scan camera-based spectrometer, we demonstrated real-time full-range FD-OCT at 34 frame/s (1024 pixel lateral x 2048 pixel axial). (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3645088]
引用
收藏
页数:6
相关论文
共 37 条
[1]   Two-axis MEMS scanning catheter for ultrahigh resolution three-dimensional and en face imaging [J].
Aguirre, Aaron D. ;
Herz, Paul R. ;
Chen, Yu ;
Fujimoto, James G. ;
Piyawattanametha, Wibool ;
Fan, Li ;
Wu, Ming C. .
OPTICS EXPRESS, 2007, 15 (05) :2445-2453
[2]   Full range complex spectral domain optical coherence tomography without additional phase shifters [J].
Baumann, Bernhard ;
Pircher, Michael ;
Goetzinger, Erich ;
Hitzenberger, Christoph K. .
OPTICS EXPRESS, 2007, 15 (20) :13375-13387
[3]   In vivo Fourier-domain full-field OCT of the human retina with 1.5 million A-lines/s [J].
Bonin, Tim ;
Franke, Gesa ;
Hagen-Eggert, Martin ;
Koch, Peter ;
Huettmann, Gereon .
OPTICS LETTERS, 2010, 35 (20) :3432-3434
[4]  
Boppart S.A., 2001, Handbook of Optical Coherence Tomography
[5]   Intraoperative assessment of microsurgery with three-dimensional optical coherence tomography [J].
Boppart, SA ;
Bouma, BE ;
Pitris, C ;
Southern, JF ;
Brezinski, ME ;
Fujimoto, JG .
RADIOLOGY, 1998, 208 (01) :81-86
[6]   Real-time monitoring of cardiac radio-frequency ablation lesion formation using an optical coherence tomography forward-imaging catheter [J].
Fleming, Christine P. ;
Wang, Hui ;
Quan, Kara J. ;
Rollins, Andrew M. .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (03)
[7]   Piezoelectric scanning mirrors for endoscopic optical coherence tomography [J].
Gilchrist, Kristin H. ;
McNabb, Ryan P. ;
Izatt, Joseph A. ;
Grego, Sonia .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2009, 19 (09)
[8]   Buffered Fourier domain mode locking: unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s [J].
Huber, Robert ;
Adler, Desmond C. ;
Fujimoto, James G. .
OPTICS LETTERS, 2006, 31 (20) :2975-2977
[9]   Forward-viewing resonant fiber-optic scanning endoscope of appropriate scanning speed for 3D OCT imaging [J].
Huo, Li ;
Xi, Jiefeng ;
Wu, Yicong ;
Li, Xingde .
OPTICS EXPRESS, 2010, 18 (14) :14375-14384
[10]   Optical coherence tomography guided neurosurgical procedures in small rodents [J].
Jafri, M. Samir ;
Tang, Rebecca ;
Tang, Cha-Min .
JOURNAL OF NEUROSCIENCE METHODS, 2009, 176 (02) :85-95