Ultraviolet-C (UV-C) monitoring made simple: Colorimetric indicators to assess delivery of UV-C light by room decontamination devices

被引:8
|
作者
Cadnum, Jennifer L. [1 ]
Pearlmutter, Basya S. [1 ]
Redmond, Sarah N. [2 ]
Jencson, Annette L. [1 ]
Benner, Kevin J. [3 ]
Donskey, Curtis J. [2 ,4 ]
机构
[1] Louis Stokes Cleveland Vet Affairs VA Med Ctr, Res Serv, Cleveland, OH USA
[2] Case Western Reserve Univ, Sch Med, Cleveland, OH 44106 USA
[3] GE Current, Cleveland, OH USA
[4] Louis Stokes Cleveland VA Med Ctr, Geriatr Res Educ & Clin Ctr, Cleveland, OH 44106 USA
来源
关键词
CANDIDA-AURIS;
D O I
10.1017/ice.2021.113
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objective: To evaluate the use of colorimetric indicators for monitoring ultraviolet-C (UV-C) light delivery to sites in patient rooms. Methods: In laboratory testing, we examined the correlation between changes in color of 2 commercial colorimetric indicators and log(10) reductions in methicillin-resistant Staphylococcus aureus (MRSA) and Clostridioides difficile spores with exposure to increasing doses of UV-C from a low-pressure mercury room decontamination device. In patient rooms, 1 of the colorimetric indicators was used to assess UV-C dose delivery to 27 sites in the room. Results: In laboratory testing, the manufacturer's reference colors for MRSA and C. difficile reduction corresponded with doses of similar to 10,000 and 46,000 mu J/cm(2); these doses resulted in >3 log(10) reductions in MRSA and C. difficile spores, respectively. In patient rooms, the colorimetric indicators demonstrated suboptimal delivery of UV-C dosing to shadowed areas, which was improved by providing cycles on each side of the patient bed rather than in a single position and altering device placement. Increasing duration of exposure increased the number of sites achieving adequate dosing to kill C. difficile spores. Conclusions: Commercial colorimetric indicators provide rapid and easy-to-interpret information on the UV-C dose delivered to sites in patient rooms. The indicators may be useful for training environmental services personnel and optimizing the effectiveness of UV-C room decontamination devices.
引用
收藏
页码:306 / 311
页数:6
相关论文
共 50 条
  • [31] Decontamination Efficiency of a DBD Lamp Containing an UV-C Emitting Phosphor
    Caillier, Bruno
    Almeida Caiut, Jose Mauricio
    Muja, Cristina
    Demoucron, Julien
    Mauricot, Robert
    Dexpert-Ghys, Jeanette
    Guillot, Philippe
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2015, 91 (03) : 526 - 532
  • [32] Evaluating UV-C Sensitivity of Calonectria pseudonaviculata in Model Buffer Solution Using a UV-C Light-Emitting-Diode System
    Ghimire, Bhawana
    Pendyala, Brahmaiah
    Patras, Ankit
    Baysal-Gurel, Fulya
    PLANT DISEASE, 2024, 108 (09) : 2663 - 2667
  • [33] Disinfecting handheld electronic devices with UV-C in a healthcare setting
    Cremers-Pijpers, Suzan
    van Rossum, Carsten
    Dautzenberg, Mirjam
    Wertheim, Heiman
    Tostmann, Alma
    Hopman, Joost
    INFECTION PREVENTION IN PRACTICE, 2021, 3 (02)
  • [34] Physiological Responses of Scenedesmus quadricauda (Chlorophyceae) to UV-A and UV-C Light
    Kovacik, Jozef
    Klejdus, Borivoj
    Backor, Martin
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2010, 86 (03) : 612 - 616
  • [35] Inactivation of avirulent pgm+ and Δpgm Yersinia pestis by ultraviolet light (UV-C)
    Paoli, George C.
    Sommers, Christopher H.
    Scullen, O. Joseph
    Wijey, Chandi
    FOOD MICROBIOLOGY, 2014, 44 : 168 - 172
  • [36] Greater than 3-Log Reduction in Viable Coronavirus Aerosol Concentration in Ducted Ultraviolet-C (UV-C) Systems
    Qiao, Yuechen
    Yang, My
    Marabella, Ian A.
    McGee, Devin A. J.
    Aboubakr, Hamada
    Goyal, Sagar
    Hogan Jr, Christopher J.
    Olson, Bernard A.
    Torremorell, Montserrat
    Environmental Science and Technology, 2021, 55 (07): : 4174 - 4182
  • [37] Assessment of Oxidative Damage in the Primary Mouse Ocular Surface Cells/Stem Cells in Response to Ultraviolet-C (UV-C) Damage
    Bose, Bipasha
    Kapoor, Saketh
    Sen, Utsav
    Nihad, Muhammad
    Chaudhury, Debajit
    Shenoy, Sudheer P.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (156):
  • [38] Greater than 3-Log Reduction in Viable Coronavirus Aerosol Concentration in Ducted Ultraviolet-C (UV-C) Systems
    Qiao, Yuechen
    Yang, My
    Marabella, Ian A.
    McGee, Devin A. J.
    Aboubakr, Hamada
    Goyal, Sagar
    Hogan, Christopher J., Jr.
    Olson, Bernard A.
    Torremorell, Montserrat
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2021, 55 (07) : 4174 - 4182
  • [39] UV-C AND GERMICIDAL LIGHT: WHAT WE'VE LEARNED
    Litvin, Dan
    Lighting Design and Application: LD and A, 2022, 52 (02) : 48 - 51
  • [40] Valorization of ultraviolet-C (UV-C) dose validation in spices: Changes in phenolic contents and antioxidant activity during storage of UV-C-treated dried spices powder
    Qasem, Akram A.
    Ibraheem, Mohamed A.
    Hamami, Mshari A. H.
    Al-Shoqairan, Yaser I.
    Alamri, Mohamed Saleh
    Al Maiman, Salah A.
    Hassan, Amro B.
    ITALIAN JOURNAL OF FOOD SCIENCE, 2024, 36 (02) : 111 - 120