Flow injection determination of hydrogen peroxide by bis(2,4,6-trichlorophenyl)oxalate chemiluminescence in O/W emulsion

被引:11
作者
Hasebe, T [1 ]
Hasegawa, E [1 ]
Kawashima, T [1 ]
机构
[1] UNIV TSUKUBA,DEPT CHEM,ANALYT CHEM LAB,TSUKUBA,IBARAKI 305,JAPAN
关键词
flow injection analysis; hydrogen peroxide; glutamic acid; bis(2,4,6-trichlorophenyl)oxalate; ethyl acetate water Tween 20 O/W emulsion;
D O I
10.2116/analsci.12.881
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection (FIA) determination of hydrogen peroxide (H2O2) was developed by using chemiluminescence (CL) reaction of bis(2,4,6-trichlorophenyl)oxalate (TCPO) in an oil/water (O/W) emulsion system composed of ethyl acetate, non-ionic surfactant polyoxyethylene(20) sorbitane monolaurate(Tween 20) and water. The intensity of the light emitted from the CL reaction is proportional to the concentration of H2O2. A linear calibration graph was obtained over the H2O2 concentration range 1 x 10(-6) - 1 x 10(-3) mol dm(-3). The relative standard deviations of 3.4 and 3.6% were obtained for five determinations of 1 x 10(-5) and 1 x 10(-6) mol dm(-3) of H2O2, respectively. The present method was applied to the determination of L-glutamic acid in culture medium, which was based on the detection of H2O2 produced from glutamic acid in the immobilized glutamate oxidase reactor in the flow system.
引用
收藏
页码:881 / 885
页数:5
相关论文
共 22 条
  • [1] AKIBA M, 1987, BUNSEKI KAGAKU, V36, P561
  • [2] STABILITY OF BIS(2,4,6-TRICHLOROPHENYL) OXALATE IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR CHEMI-LUMINESCENCE DETECTION
    IMAIZUMI, N
    HAYAKAWA, K
    MIYAZAKI, M
    IMAI, K
    [J]. ANALYST, 1989, 114 (02) : 161 - 164
  • [3] REAGENT-INJECTION FLOW-ANALYSIS - APPLICATION TO THE DETERMINATION OF NANOMOLAR LEVELS OF HYDROGEN-PEROXIDE IN SEAWATER
    JOHNSON, KS
    SAKAMOTOARNOLD, CM
    WILLASON, SW
    BEEHLER, CL
    [J]. ANALYTICA CHIMICA ACTA, 1987, 201 : 83 - 94
  • [4] DETERMINATION OF HYDROGEN-PEROXIDE BY FLOW-INJECTION ANALYSIS WITH ARYL OXALATE-SULFORHODAMINE-101 CHEMILUMINESCENCE
    KATAYAMA, M
    TAKEUCHI, H
    TANIGUCHI, H
    [J]. ANALYTICAL LETTERS, 1991, 24 (06) : 1005 - 1015
  • [5] FLOW-INJECTION DETERMINATION OF GLUCOSE IN SERUM WITH AN IMMOBILIZED PYRANOSE OXIDASE REACTOR
    KIBA, N
    UEDA, F
    FURUSAWA, M
    YAMANE, T
    [J]. ANALYTICA CHIMICA ACTA, 1992, 269 (02) : 187 - 191
  • [6] MASOOM M, 1984, ANAL CHIM ACTA, V166, P111
  • [7] OXO[5,10,15,20-TETRA(4-PYRIDYL)PORPHYRINATO]TITANIUM(IV) - AN ULTRA-HIGH SENSITIVITY SPECTROPHOTOMETRIC REAGENT FOR HYDROGEN-PEROXIDE
    MATSUBARA, C
    KAWAMOTO, N
    TAKAMURA, K
    [J]. ANALYST, 1992, 117 (11) : 1781 - 1784
  • [8] MATSUBARA C, 1995, J FLOW INJECTION ANA, V12, P23
  • [9] FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION OF GLUCOSE AND URIC-ACID USING IMMOBILIZED ENZYME REACTOR
    NAKASHIMA, K
    HAYASHIDA, N
    KAWAGUCHI, S
    AKIYAMA, S
    TSUKAMOTO, Y
    IMAI, K
    [J]. ANALYTICAL SCIENCES, 1991, 7 (05) : 715 - 718
  • [10] PESCE MA, 1977, CLIN CHEM, V23, P757