Flow injection determination of hydrogen peroxide by bis(2,4,6-trichlorophenyl)oxalate chemiluminescence in O/W emulsion

被引:11
作者
Hasebe, T [1 ]
Hasegawa, E [1 ]
Kawashima, T [1 ]
机构
[1] UNIV TSUKUBA,DEPT CHEM,ANALYT CHEM LAB,TSUKUBA,IBARAKI 305,JAPAN
关键词
flow injection analysis; hydrogen peroxide; glutamic acid; bis(2,4,6-trichlorophenyl)oxalate; ethyl acetate water Tween 20 O/W emulsion;
D O I
10.2116/analsci.12.881
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection (FIA) determination of hydrogen peroxide (H2O2) was developed by using chemiluminescence (CL) reaction of bis(2,4,6-trichlorophenyl)oxalate (TCPO) in an oil/water (O/W) emulsion system composed of ethyl acetate, non-ionic surfactant polyoxyethylene(20) sorbitane monolaurate(Tween 20) and water. The intensity of the light emitted from the CL reaction is proportional to the concentration of H2O2. A linear calibration graph was obtained over the H2O2 concentration range 1 x 10(-6) - 1 x 10(-3) mol dm(-3). The relative standard deviations of 3.4 and 3.6% were obtained for five determinations of 1 x 10(-5) and 1 x 10(-6) mol dm(-3) of H2O2, respectively. The present method was applied to the determination of L-glutamic acid in culture medium, which was based on the detection of H2O2 produced from glutamic acid in the immobilized glutamate oxidase reactor in the flow system.
引用
收藏
页码:881 / 885
页数:5
相关论文
共 22 条
[1]  
AKIBA M, 1987, BUNSEKI KAGAKU, V36, P561
[2]   STABILITY OF BIS(2,4,6-TRICHLOROPHENYL) OXALATE IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR CHEMI-LUMINESCENCE DETECTION [J].
IMAIZUMI, N ;
HAYAKAWA, K ;
MIYAZAKI, M ;
IMAI, K .
ANALYST, 1989, 114 (02) :161-164
[3]   REAGENT-INJECTION FLOW-ANALYSIS - APPLICATION TO THE DETERMINATION OF NANOMOLAR LEVELS OF HYDROGEN-PEROXIDE IN SEAWATER [J].
JOHNSON, KS ;
SAKAMOTOARNOLD, CM ;
WILLASON, SW ;
BEEHLER, CL .
ANALYTICA CHIMICA ACTA, 1987, 201 :83-94
[4]   DETERMINATION OF HYDROGEN-PEROXIDE BY FLOW-INJECTION ANALYSIS WITH ARYL OXALATE-SULFORHODAMINE-101 CHEMILUMINESCENCE [J].
KATAYAMA, M ;
TAKEUCHI, H ;
TANIGUCHI, H .
ANALYTICAL LETTERS, 1991, 24 (06) :1005-1015
[5]   FLOW-INJECTION DETERMINATION OF GLUCOSE IN SERUM WITH AN IMMOBILIZED PYRANOSE OXIDASE REACTOR [J].
KIBA, N ;
UEDA, F ;
FURUSAWA, M ;
YAMANE, T .
ANALYTICA CHIMICA ACTA, 1992, 269 (02) :187-191
[6]  
MASOOM M, 1984, ANAL CHIM ACTA, V166, P111
[7]   OXO[5,10,15,20-TETRA(4-PYRIDYL)PORPHYRINATO]TITANIUM(IV) - AN ULTRA-HIGH SENSITIVITY SPECTROPHOTOMETRIC REAGENT FOR HYDROGEN-PEROXIDE [J].
MATSUBARA, C ;
KAWAMOTO, N ;
TAKAMURA, K .
ANALYST, 1992, 117 (11) :1781-1784
[8]  
MATSUBARA C, 1995, J FLOW INJECTION ANA, V12, P23
[9]   FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION OF GLUCOSE AND URIC-ACID USING IMMOBILIZED ENZYME REACTOR [J].
NAKASHIMA, K ;
HAYASHIDA, N ;
KAWAGUCHI, S ;
AKIYAMA, S ;
TSUKAMOTO, Y ;
IMAI, K .
ANALYTICAL SCIENCES, 1991, 7 (05) :715-718
[10]  
PESCE MA, 1977, CLIN CHEM, V23, P757