Incidence, indications and predicting factors of permanent pacemaker implantation after transcatheter aortic valve implantation: A retrospective study

被引:17
作者
Becker, Mathieu [1 ]
Blangy, Hugues [1 ]
Folliguet, Thierry [1 ,2 ]
Villemin, Thibault [1 ,2 ]
Freysz, Luc [1 ]
Luc, Amandine [3 ]
Maureira, Pablo [1 ,2 ]
Popovic, Batric [1 ]
Olivier, Arnaud [1 ,2 ]
Sadoul, Nicolas [1 ,2 ]
机构
[1] CHU Nancy, Dept Cardiol, F-54511 Vandoeuvre Les Nancy, France
[2] Univ Lorraine, F-54000 Nancy, France
[3] Univ Hosp Nancy, PARC, ESPRI Biobase Unit, F-54511 Vandoeuvre Les Nancy, France
关键词
Transcatheter aortic valve implantation; Aortic stenosis; Permanent pacemaker implantation; Predicting factors; Incidence; BUNDLE-BRANCH BLOCK; INTRAVENTRICULAR-CONDUCTION DISTURBANCES; HEART-ASSOCIATION ELECTROCARDIOGRAPHY; MULTIDETECTOR COMPUTED-TOMOGRAPHY; BALLOON-EXPANDABLE VALVE; OF-CARDIOLOGY-FOUNDATION; ARRHYTHMIAS COMMITTEE; SCIENTIFIC STATEMENT; CLINICAL CARDIOLOGY; RHYTHM-SOCIETY;
D O I
10.1016/j.acvd.2017.03.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - As the number of transcatheter aortic valve implantation (TAVI) procedures is constantly increasing, it is important to consider common complications, such as pacemaker (PM) implantation, and their specific risk factors. Aims. - Echocardiographic, computed tomography and electrocardiographic data were analysed to determine the predicting factors, if any, associated with PM implantation. Methods.- This retrospective study included patients referred to Nancy University Hospital for a TAVI procedure from January 2013 to December 2015. Both Medtronic CoreValve and Edwards SAPIEN valves were implanted. Patients with preprocedurally implanted PMs and/or referred from another institution were excluded. Results. - Of 208 TAVI patients, 23 had a pre-existing PM and were excluded. A new PM was required in 38 patients (20.5%). Pre-existing right bundle branch block (RBBB), the use of the Medtronic CoreValve and large prostheses were identified as predictors of PM implantation (P=0.0361, P=0.0004 and P=0.0019,respectively). Using logistic regression, predictors of PM implantation included first-degree atrioventricular block (odds ratio 3.7, 95% confidence interval 1.5-9.1; P=0.0054) and large aortic annulus diameter in echocardiography (odds ratio 1.2, 95% confidence interval 1-1.4; P=0.0447), with a threshold of 24.1 mm. For the combination of preTAVI PR duration > 220 ms and QRS duration > 120 ms, the positive predictive value for PM implantation reached 80%. Conclusion. - Use of the Medtronic CoreValve, RBBB and first-degree atrioventricular block are major risk factors for post-TAVI PM implantation. In addition, large aortic annulus and large valvular prosthesis are independent risk factors for PM implantation. The combination of preTAVI prolonged PR interval and increased QRS duration could be used as a marker for periprocedural PM implantation. (C) 2017 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:508 / 516
页数:9
相关论文
共 46 条
  • [1] SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)
    Achenbach, Stephan
    Delgado, Victoria
    Hausleiter, Joerg
    Schoenhagen, Paul
    Min, James K.
    Leipsic, Jonathon A.
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) : 366 - 380
  • [2] Incidence and predictors of left bundle branch block after transcatheter aortic valve implantation
    Aktug, Oemer
    Dohmen, Guido
    Brehmer, Kathrin
    Koos, Ralph
    Altiok, Ertunc
    Deserno, Verena
    Herpertz, Ralf
    Autschbach, Ruediger
    Marx, Nikolaus
    Hoffmann, Rainer
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 160 (01) : 26 - 30
  • [3] Role of Echocardiography Before Transcatheter Aortic Valve Implantation (TAVI)
    Badiani, Sveeta
    Bhattacharyya, Sanjeev
    Lloyd, Guy
    [J]. CURRENT CARDIOLOGY REPORTS, 2016, 18 (04)
  • [4] The Impact of Integration of a Multidetector Computed Tomography Annulus Area Sizing Algorithm on Outcomes of Transcatheter Aortic Valve Replacement A Prospective, Multicenter, Controlled Trial
    Binder, Ronald K.
    Webb, John G.
    Willson, Alexander B.
    Urena, Marina
    Hansson, Nicolaj C.
    Norgaard, Bjarne L.
    Pibarot, Philippe
    Barbanti, Marco
    Larose, Eric
    Freeman, Melanie
    Dumont, Eric
    Thompson, Chris
    Wheeler, Miriam
    Moss, Robert R.
    Yang, Tae-hyun
    Pasian, Sergio
    Hague, Cameron J.
    Giang Nguyen
    Raju, Rekha
    Toggweiler, Stefan
    Min, James K.
    Wood, David A.
    Rodes-Cabau, Josep
    Leipsic, Jonathon
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (05) : 431 - 438
  • [5] 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
    Brignole, Michele
    Auricchio, Angelo
    Baron-Esquivias, Gonzalo
    Bordachar, Pierre
    Boriani, Giuseppe
    Breithardt, Ole-A
    Cleland, John
    Deharo, Jean-Claude
    Delgado, Victoria
    Elliott, Perry M.
    Gorenek, Bulent
    Israel, Carsten W.
    Leclercq, Christophe
    Linde, Cecilia
    Mont, Llus
    Padeletti, Luigi
    Sutton, Richard
    Vardas, Panos E.
    Zamorano, Jose Luis
    Achenbach, Stephan
    Baumgartner, Helmut
    Bax, Jeroen J.
    Bueno, Hctor
    Dean, Veronica
    Deaton, Christi
    Erol, Cetin
    Fagard, Robert
    Ferrari, Roberto
    Hasdai, David
    Hoes, Arno W.
    Kirchhof, Paulus
    Knuuti, Juhani
    Kolh, Philippe
    Lancellotti, Patrizio
    Linhart, Ales
    Nihoyannopoulos, Petros
    Piepoli, Massimo F.
    Ponikowski, Piotr
    Sirnes, Per Anton
    Tamargo, Juan Luis
    Tendera, Michal
    Torbicki, Adam
    Wijns, William
    Windecker, Stephan
    Kirchhof, Paulus
    Blomstrom-Lundqvist, Carina
    Badano, Luigi P.
    Aliyev, Farid
    Bnsch, Dietmar
    Baumgartner, Helmut
    [J]. EUROPACE, 2013, 15 (08): : 1070 - 1118
  • [6] Incidence rate and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis
    Calvi, Valeria
    Conti, Sergio
    Pruiti, Giusi Paola
    Capodanno, Davide
    Puzzangara, Euglena
    Tempio, Donatella
    Di Grazia, Angelo
    Ussia, Gian Paolo
    Tamburino, Corrado
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (02) : 189 - 195
  • [7] Transcatheter Aortic Valve Implantation With the Edwards SAPIEN Versus the Medtronic CoreValve Revalving System Devices A Multicenter Collaborative Study: The PRAGMATIC Plus Initiative (Pooled-RotterdAm-Milano-Toulouse In Collaboration)
    Chieffo, Alaide
    Buchanan, Gill Louise
    Van Mieghem, Nicolas M.
    Tchetche, Didier
    Dumonteil, Nicolas
    Latib, Azeem
    van der Boon, Robert M. A.
    Vahdat, Olivier
    Marcheix, Bertrand
    Farah, Bruno
    Serruys, Patrick W.
    Fajadet, Jean
    Carrie, Didier
    de Jaegere, Peter P. T.
    Colombo, Antonio
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (08) : 830 - 836
  • [8] Echocardiography for transcatheter aortic valve implantation
    Chin, Derek
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01): : I21 - I29
  • [9] Czerwinska K, 2012, KARDIOL POL, V70, P121
  • [10] Multimodality imaging in transcatheter aortic valve implantation: key steps to assess procedural feasibility
    Delgado, Victoria
    Ewe, See Hooi
    Ng, Arnold C. T.
    van der Kley, Frank
    Marsan, Nina Ajmone
    Schuijf, Joanne D.
    Schalij, Martin J.
    Bax, Jeroen J.
    [J]. EUROINTERVENTION, 2010, 6 (05) : 643 - 652