Evaluation of point-of-care tests for cutaneous leishmaniasis diagnosis in Kabul, Afghanistan

被引:37
作者
Vink, Martijn M. T. [1 ]
Nahzat, Sami M. [2 ]
Rahimi, Habiburrahman [3 ]
Buhler, Cyril [4 ]
Ahmadi, Bashir A. [2 ]
Nader, Mohammad [3 ]
Zazai, Fazal R. [2 ]
Yousufzai, Abdul S. [5 ]
van Loenen, Merlin [6 ]
Schallig, Henk D. F. H. [6 ]
Picado, Albert [7 ]
Cruz, Israel [7 ]
机构
[1] Hlth Net TPO, Hlth Works, Lizzy Ansinghstr 163, NL-1072 RC Amsterdam, Netherlands
[2] Minist Publ Hlth, Natl Malaria & Leishmaniasis Control Programme, Darul Aman Rd,Sanatoriam St, Kabul, Afghanistan
[3] Hlth Protect & Res Org, Darul Aman Rd,Sanatoriam St, Kabul, Afghanistan
[4] ORDiagnost SASU, 10Rue Irenee Blanc, F-75020 Paris, France
[5] Hlth Net TPO, Hlth Works, Kabul, Afghanistan
[6] Univ Amsterdam, Amsterdam UMC, Med Microbiol, Parasitol Unit, Meibergdreef 9, Amsterdam, Netherlands
[7] Fdn Innovat New Diagnost, Campus Biotech,Chemin Mines 9, CH-1202 Geneva, Switzerland
来源
EBIOMEDICINE | 2018年 / 37卷
关键词
MOLECULAR DIAGNOSIS; PCR; TOOL;
D O I
10.1016/j.ebiom.2018.10.063
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Kabul (Afghanistan) is a major focus of cutaneous leishmaniasis (CL) caused by Leishmania tropica. Microscopy remains the reference test for diagnosis despite its low performance. We evaluated whether Loopamp Leishmania (TM) Detection Kit (Loopamp) and CL Detects" Rapid Test (CL Detect), detecting Leishmania DNA and antigen, respectively could improve CL diagnosis. Methods: A diagnostic accuracy study with prospective inclusion was conducted in a leishmaniasis reference clinic in Kabul. Slit skin samples from CL suspects were analysed by microscopy. Samples taken with a dental broach were tested with CL Detect, Loopamp, and PCR. All samples were transferred to the Academic Medical Center (AMC, the Netherlands) for PCR and Loopamp analyses. The diagnostic performance of the tests was evaluated against a reference combining microscopy and PCR. Findings: 274 CL suspects were included in the study. In Kabul, CL Detect had a 65-4% sensitivity [95% Confidence Interval (CI): 59.2-71.2%] and a 100% specificity [95% 0: 80.5-100%], while these were 87.6% [95%Ch 82.9-913%] and 70.6% [95% CI: 44.0-89.7%] for Loopamp. At AMC the Loopamp's sensitivity (922% [95% CI: 882-95.2%]) and specificity (94.1% [95% CI: 713-99.8%]) were higher. An algorithm where CL Detect negative suspects would be tested by Loopamp yielded a 93.4% sensitivity [95% CI: 89.6-96.1%] and a 94.1% specificity [95% CI: 71.3-99.8%] when Loopamp's performance at AMC was used. Interpretation: The high specificity of CL Detect and the performance of Loopamp allow their use in a diagnostic algorithm that would minimize the number of CL patients referred for confirmation. (C) 2018 The Authors. Published by Elsevier B.V.
引用
收藏
页码:453 / 460
页数:8
相关论文
共 50 条
[31]   Comparison of a Point-of-Care FilmArray Test to Standard-of-Care Microbiology Test in Diagnosis of Healthcare Associated Infections in a Tertiary Care Pediatric Intensive Care Unit [J].
El-Nawawy, Ahmed A. ;
Antonios, Manal A. ;
Tawfik, Medhat E. ;
Meheissen, Marwa A. .
ANTIBIOTICS-BASEL, 2022, 11 (04)
[32]   Trends in Molecular Diagnosis of Nosocomial Pneumonia Classic PCR vs. Point-of-Care PCR: A Narrative Review [J].
Balan, Andrei-Mihai ;
Bodolea, Constantin ;
Tranca, Sebastian Daniel ;
Hagau, Natalia .
HEALTHCARE, 2023, 11 (09)
[33]   Low-Cost, Real-Time Polymerase Chain Reaction System for Point-of-Care Medical Diagnosis [J].
Kadja, Tchamie ;
Liu, Chengkun ;
Sun, Yvonne ;
Chodavarapu, Vamsy P. .
SENSORS, 2022, 22 (06)
[34]   Differential Diagnosis of Malaria on Truelab Uno®, a Portable, Real-Time, MicroPCR Device for Point-Of-Care Applications [J].
Nair, Chandrasekhar Bhaskaran ;
Manjula, Jagannath ;
Subramani, Pradeep Annamalai ;
Nagendrappa, Prakash B. ;
Manoj, Mulakkapurath Narayanan ;
Malpani, Sukriti ;
Pullela, Phani Kumar ;
Subbarao, Pillarisetti Venkata ;
Ramamoorthy, Siva ;
Ghosh, Susanta K. .
PLOS ONE, 2016, 11 (01)
[35]   Rapid diagnosis of Plasmodium falciparum malaria using a point-of-care loop-mediated isothermal amplification device [J].
Puri, Madhu ;
Kaur Brar, Harsimran ;
Madan, Evanka ;
Srinivasan, Rajesh ;
Rawat, Kapil ;
Gorthi, Sai Siva ;
Kumari, Geeta ;
Sah, Raj ;
Ojha, Sashi Bhusan ;
Panigrahi, Subhendu ;
Dhangadamajhi, Gunanidhi ;
Muthuswami, Rohini ;
Singh, Shailja ;
Madhubala, Rentala .
FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2022, 12
[36]   Evaluation of remote radiologist-interpreted point-of-care ultrasound for suspected dengue patients in a primary health care facility in Colombia [J].
Osorio, Lyda ;
Prieto, Inigo ;
Zuluaga, Daniela ;
Ropero, Deliana ;
Dewan, Neelesh ;
Kirsch, Jonathan D. .
INFECTIOUS DISEASES OF POVERTY, 2023, 12 (01)
[37]   An Improved Point-of-Care ELISA for the Diagnosis of Anaplasmosis and Ehrlichiosis During the Acute Phase of Tick-Borne Infections in Dogs [J].
Beall, Melissa J. ;
Mainville, Celine A. ;
Arguello-Marin, Andrea ;
Clark, Genevieve ;
Lemieux, Christine ;
Saucier, Jill ;
Thatcher, Brendon ;
Breitschwerdt, Edward B. ;
Cohn, Leah A. ;
Qurollo, Barbara A. ;
Chandrashekar, Ramaswamy .
TOPICS IN COMPANION ANIMAL MEDICINE, 2022, 51
[38]   A low cost point-of-care viscous sample preparation device for molecular diagnosis in the developing world; an example of microfluidic origami [J].
Govindarajan, A. V. ;
Ramachandran, S. ;
Vigil, G. D. ;
Yager, P. ;
Boehringer, K. F. .
LAB ON A CHIP, 2012, 12 (01) :174-181
[39]   Evaluation of immunochromatographic point-of care tests for the detection of calf diarrhoea pathogens in faecal samples [J].
Lichtmannsperger, K. ;
Freudenthaler, K. ;
Hinney, B. ;
Joachim, A. ;
Auer, A. ;
Rumenapf, T. ;
Spergserf, J. ;
Tichy, A. ;
Wittek, T. .
WIENER TIERARZTLICHE MONATSSCHRIFT, 2022, 109
[40]   A New and Highly Sensitive Serum Mannoprotein Lateral Flow Assay for Point-of-Care Diagnosis of Invasive Aspergillosis (Tripathy Method) [J].
Chaturvedi, Chandra P. ;
Hashim, Zia ;
Tripathy, Naresh K. .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (06)