T1-Corrected Fat Quantification Using Chemical Shift-Based Water/Fat Separation: Application to Skeletal Muscle

被引:104
作者
Karampinos, Dimitrios C. [1 ]
Yu, Huanzhou [2 ]
Shimakawa, Ann [2 ]
Link, Thomas M. [1 ]
Majumdar, Sharmila [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
关键词
water/fat separation; fat quantification; intermuscular adipose tissue; INTERMUSCULAR ADIPOSE-TISSUE; RELAXATION-TIMES; IN-VIVO; MRI; T-1; DECOMPOSITION; IDEAL; RESOLUTION; LIPIDS; T-2-ASTERISK;
D O I
10.1002/mrm.22925
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chemical shift-based water/fat separation, like iterative decomposition of water and fat with echo asymmetry and least-squares estimation, has been proposed for quantifying intermuscular adipose tissue. An important confounding factor in iterative decomposition of water and fat with echo asymmetry and least-squares estimation-based intermuscular adipose tissue quantification is the large difference in T-1 between muscle and fat, which can cause significant overestimation in the fat fraction. This T-1 bias effect is usually reduced by using small flip angles. T-1-correction can be performed by using at least two different flip angles and fitting for T-1 of water and fat. In this work, a novel approach for the water/fat separation problem in a dual flip angle experiment is introduced and a new approach for the selection of the two flip angles, labeled as the unequal small flip angle approach, is developed, aiming to improve the noise efficiency of the T-1-correction step relative to existing approaches. It is shown that the use of flip angles, selected such the muscle water signal is assumed to be T-1-independent for the first flip angle and the fat signal is assumed to be T-1-independent for the second flip angle, has superior noise performance to the use of equal small flip angles (no T1 estimation required) and the use of large flip angles (T-1 estimation required). Magn Reson Med 66: 1312-1326, 2011. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1312 / 1326
页数:15
相关论文
共 50 条
[1]   In vivo determination of intra-myocellular lipids in human muscle by means of localized H-1-MR-spectroscopy [J].
Boesch, C ;
Slotboom, J ;
Hoppeler, H ;
Kreis, R .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) :484-493
[2]   Role of proton MR for the study of muscle lipid metabolism [J].
Boesch, Chris ;
Machann, Juergen ;
Vermathen, Peter ;
Schick, Fritz .
NMR IN BIOMEDICINE, 2006, 19 (07) :968-988
[3]   Intermuscular Adipose Tissue (IMAT): Association With Other Adipose Tissue Compartments and Insulin Sensitivity [J].
Boettcher, Michael ;
Machann, Juergen ;
Stefan, Norbert ;
Thame, Claus ;
Haering, Hans-Ulrich ;
Claussen, Claus D. ;
Fritsche, Andreas ;
Schick, Fritz .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (06) :1340-1345
[4]  
Brookes JA, 1999, JMRI-J MAGN RESON IM, V9, P163, DOI 10.1002/(SICI)1522-2586(199902)9:2<163::AID-JMRI3>3.0.CO
[5]  
2-L
[6]  
Bydder M, 2010, P 18 ANN M ISMRM STO, P2822
[7]   Relaxation effects in the quantification of fat using gradient echo imaging [J].
Bydder, Mark ;
Yokoo, Takeshi ;
Hamilton, Gavin ;
Middleton, Michael S. ;
Chavez, Alyssa D. ;
Schwimmer, Jeffrey B. ;
Lavine, Joel E. ;
Sirlin, Claude B. .
MAGNETIC RESONANCE IMAGING, 2008, 26 (03) :347-359
[8]   Assessment of liver fat quantification in the presence of iron [J].
Bydder, Mark ;
Shiehmorteza, Masoud ;
Yokoo, Takeshi ;
Sugay, Sebastian ;
Middleton, Michael S. ;
Girard, Olivier ;
Schroeder, Michael E. ;
Wolfson, Tanya ;
Gamst, Anthony ;
Sirlin, Claude .
MAGNETIC RESONANCE IMAGING, 2010, 28 (06) :767-776
[9]  
Chebrolu V, 2010, P 18 ANN M ISMRM STO, P2908
[10]   Independent Estimation of T2* for Water and Fat for Improved Accuracy of Fat Quantification [J].
Chebrolu, Venkata V. ;
Hines, Catherine D. G. ;
Yu, Huanzhou ;
Pineda, Angel R. ;
Shimakawa, Ann ;
McKenzie, Charles A. ;
Samsonov, Alexey ;
Brittain, Jean H. ;
Reeder, Scott B. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) :849-857