Diagnostic accuracy of ultrasound for rotator cuff tears in adults: A systematic review and meta-analysis

被引:109
作者
Smith, T. O. [1 ]
Back, T. [2 ]
Toms, A. P. [3 ]
Hing, C. B. [4 ]
机构
[1] Univ E Anglia, Fac Hlth, Dept Physiotherapy, Norwich NR4 7TJ, Norfolk, England
[2] Norfolk & Norwich Univ Hosp, Dept Physiotherapy, London, England
[3] Norfolk & Norwich Univ Hosp, Dept Radiol, London, England
[4] St George Hosp, Dept Orthopaed Surg, London, England
关键词
SUPRASPINATUS TENDON TEARS; PARTIAL-THICKNESS TEAR; FULL-THICKNESS; SURGICAL CORRELATION; SHOULDER ULTRASOUND; PAINFUL SHOULDER; ARTHROSCOPIC FINDINGS; OPERATIVE FINDINGS; MR ARTHROGRAPHY; BICEPS TENDON;
D O I
10.1016/j.crad.2011.05.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To determine the diagnostic accuracy of ultrasound to detect partial and complete thickness rotator cuff tears based on all available clinical trials. MATERIALS AND METHODS: An electronic search of databases registering published and unpublished literature was conducted. All diagnostic accuracy studies that directly compared the accuracy of ultrasound (the index test) to either arthroscopic or open surgical findings (the reference test) for rotator cuff tear were included. The methodological quality of each included study was assessed using the QUADAS form. When appropriate, pooled sensitivity and specificity analysis was conducted, with an assessment of the summary receiver operating characteristic (ROC) curve for each analysis. RESULTS: Sixty-two studies assessing 6007 patients and 6066 shoulders were included. Ultrasonography had good sensitivity and specificity for the assessment of partial thickness (sensitivity 0.84; specificity 0.89), and full-thickness rotator cuff tears (sensitivity 0.96: specificity 0.93). However, the literature poorly described population characteristics, assessor blinding, and was based on limited sample sizes. The literature assessing transducer frequency was particularly small in size. CONCLUSION: Ultrasonography is an appropriate radiological technique for the assessment of rotator cuff tears with an acceptable sensitivity and specificity. The diagnostic test accuracy of ultrasound is superior for the detection of full-thickness compared to partial-thickness cuff tears. Further study assessing the effect of transducer frequency is warranted. (C) 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1036 / 1048
页数:13
相关论文
共 91 条
[51]   Sonography of the rotator cuff in painful shoulders performed without knowledge of clinical information: Results from 58 sonographic examinations with surgical correlation [J].
Moosmayer, Stefan ;
Heir, Stig ;
Smith, Hans-Jorgen .
JOURNAL OF CLINICAL ULTRASOUND, 2007, 35 (01) :20-26
[52]   Accuracy of ultrasonography and magnetic resonance imaging for detection of full thickness rotator cuff tears [J].
Naqvi, Gohar Abbas ;
Jadaan, Mutaz ;
Harrington, Paul .
INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2009, 3 (04) :94-97
[53]   A comparative study of ultrasonography with magnetic resonance imaging in patients with painful shoulder [J].
Naredo, AE ;
Aguado, P ;
Padrón, M ;
Bernad, M ;
Uson, J ;
Mayordomo, L ;
Martin-Mola, E .
JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 1999, 5 (04) :184-192
[54]   EVALUATION OF THE PAINFUL SHOULDER - A PROSPECTIVE COMPARISON OF MAGNETIC-RESONANCE-IMAGING, COMPUTERIZED TOMOGRAPHIC ARTHROGRAPHY, ULTRASONOGRAPHY, AND OPERATIVE FINDINGS [J].
NELSON, MC ;
LEATHER, GP ;
NIRSCHL, RP ;
PETTRONE, FA ;
FREEDMAN, MT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (05) :707-716
[55]  
Nogueira-Barbosa Marcello Henrique, 2002, Acta ortop. bras., V10, P31, DOI 10.1590/S1413-78522002000400005
[56]   Accuracy of Diagnostic Ultrasound in Patients With Suspected Subacromial Disorders: A Systematic Review and Meta-Analysis [J].
Ottenheijm, Ramon P. ;
Jansen, Mariette J. ;
Staal, J. Bart ;
van den Bruel, Ann ;
Weijers, Rene E. ;
de Bie, Rob A. ;
Dinant, Geert-Jan .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (10) :1616-1625
[57]   ULTRASONOGRAPHY AND ARTHROGRAPHY IN THE DIAGNOSIS OF TEARS OF THE ROTATOR CUFF [J].
PAAVOLAINEN, P ;
AHOVUO, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (03) :335-340
[58]  
PATTEE G A, 1988, Arthroscopy, V4, P15, DOI 10.1016/S0749-8063(88)80005-7
[59]   Accuracy of ultrasound imaging of the rotator cuff in shoulders that are painful postoperatively [J].
Prickett, WD ;
Teefey, SA ;
Galatz, LM ;
Calfee, RP ;
Middleton, WD ;
Yamaguchi, K .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (06) :1084-1089
[60]  