Comparison of the anterior ocular segment measurements using swept-source optical coherent tomography and a scanning peripheral anterior chamber depth analyzer

被引:8
作者
Furuya, Toshie [1 ]
Mabuchi, Fumihiko [1 ]
Chiba, Tatsuya [1 ]
Kogure, Satoshi [2 ]
Tsukahara, Shigeo [1 ]
Kashiwagi, Kenji [1 ,3 ]
机构
[1] Univ Yamanashi, Sch Med & Engn, Dept Ophthalmol Interdisciplinary, Chuo Ku, Yamanashi, Japan
[2] Kogure Eye Clin, Showa Ku, Yamanashi, Japan
[3] Univ Yamanashi, Interdisciplinary Sch Med & Engn, Dept Community & Family Med, Chuo Ku, Yamanashi, Japan
关键词
Anterior chamber depth; Corneal thickness; Optical coherent tomography; Angle openness; Glaucoma; PRIMARY ANGLE-CLOSURE; CENTRAL CORNEAL THICKNESS; SLIT-LAMP OCT; ULTRASOUND BIOMICROSCOPY; GLAUCOMA; EYE; POPULATION; IOLMASTER; DIAMETER; PENTACAM;
D O I
10.1007/s10384-011-0071-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare the anterior ocular segment measurements of two non-contact devices, i.e., anterior segment swept-source optical coherence tomography (SS-OCT) and the scanning peripheral anterior chamber depth analyzer (SPAC), in patients with glaucoma. This was a cross-sectional study of glaucoma patients visiting the Yamanashi University Hospital. The consistency and correlation of various parameters were studied between the SS-OCT and SPAC measurements, including the central corneal thickness (CCT), the central anterior chamber depth (ACD), the trabecular-iris angle (TIA), the angle opening distance (AOD), the area of the recessed angle (ARA), and the trabecular-iris space area (TISA) from the SS-OCT measurements, and the CCT, central ACD, SPAC grade, and SPAC-evaluated anterior chamber angle (ACA) from the SPAC measurements. Seventy right eyes of 70 patients (27 men, 43 women) with glaucoma were enrolled in the study. The mean patient age was 65.9 +/- A 14.5 years. The CCT measurements by SS-OCT and the SPAC were 528.3 +/- A 32.0 and 516.1 +/- A 28.5 mu m, respectively (P < 0.001). The central ACD measurements by SS-OCT and the SPAC were 2.39 +/- A 0.44 and 2.73 +/- A 0.50 mm, respectively (P < 0.001). The two devices showed a significant correlation in terms of the CCT measurements (R (2) = 0.667, P < 0.0001) and the central ACD measurements (R (2) = 0.86, P < 0.0001), but SS-OCT give a significantly shallower central ACD measurement and a thinner CCT measurement compared with the SPAC. AOD, TIA, TISA, and the ARA were all significantly correlated with the SPAC grade and the ACA. Consistency between the two devices was reduced among eyes with primary angle closure. Based on our results, the SS-OCT and SPAC measurements of the anterior segment were significantly correlated, but the values cannot be considered to be directly interchangeable.
引用
收藏
页码:472 / 479
页数:8
相关论文
共 32 条
[1]   Long-term clinical course of primary angle-closure glaucoma in an Asian population [J].
Alsagoff, Z ;
Aung, T ;
Ang, LPK ;
Chew, PTK .
OPHTHALMOLOGY, 2000, 107 (12) :2300-2304
[2]   Acute primary angle closure in an Asian population - Long-term outcome of the fellow eye after prophylactic laser peripheral iridotomy [J].
Ang, LPK ;
Aung, T ;
Chew, PTK .
OPHTHALMOLOGY, 2000, 107 (11) :2092-2096
[3]   Anterior chamber depth and the risk of primary angle closure in 2 East Asian populations [J].
Aung, T ;
Nolan, WP ;
Machin, D ;
Seah, SKL ;
Baasanhu, J ;
Khaw, PT ;
Johnson, GJ ;
Foster, PJ .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (04) :527-532
[4]   Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer [J].
Baikoff, G ;
Jodai, HJ ;
Bourgeon, G .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1722-1728
[5]   Prevalence and Determinants of Angle Closure in Central Sri Lanka: The Kandy Eye Study [J].
Casson, Robert J. ;
Baker, Michelle ;
Edussuriya, Kapila ;
Senaratne, Tissa ;
Selva, Dinesh ;
Sennanayake, Saman .
OPHTHALMOLOGY, 2009, 116 (08) :1444-1449
[6]   Quantitative assessment of anterior chamber volume using slit-lamp OCT and Pentacam [J].
Dinc, Umut Asli ;
Oncel, Banu ;
Gorgun, Ebru ;
Alimgil, Levent .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (03) :411-415
[7]   Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation [J].
Doors, Muriel ;
Cruysberg, Lars P. J. ;
Berendschot, Tos T. J. M. ;
de Brabander, John ;
Verbakel, Frenne ;
Webers, Carroll A. B. ;
Nuijts, Rudy M. M. A. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (08) :1139-1146
[8]   Measurement of anterior chamber volume with rotating scheimpflug camera and anterior segment optical coherence tomography [J].
Fu Jing ;
Li Shu-ning ;
Wang Xiao-zhen ;
Wu Ge-wei ;
Mu Da-peng ;
Wang Jian ;
Wang Ning-li .
CHINESE MEDICAL JOURNAL, 2010, 123 (02) :203-207
[9]   Anterior Ocular Biometry Using 3-Dimensional Optical Coherence Tomography [J].
Fukuda, Shinichi ;
Kawana, Keisuke ;
Yasuno, Yoshiaki ;
Oshika, Tetsuro .
OPHTHALMOLOGY, 2009, 116 (05) :882-889
[10]   The prevalence of primary open-angle glaucoma in Japanese - The Tajimi study [J].
Iwase, A ;
Suzuki, Y ;
Araie, M ;
Yamamoto, T ;
Abe, H ;
Shirato, S ;
Kuwayama, Y ;
Mishima, HK ;
Shimizu, H ;
Tomita, G ;
Inoue, Y ;
Kitazawa, Y .
OPHTHALMOLOGY, 2004, 111 (09) :1641-1648