Reduction in flow artifacts by using interleaved data acquisition in segmented balanced steady-state free precession cardiac MRI

被引:3
|
作者
Amano, Y
Nozaki, A
Takahama, K
Kumazaki, T
机构
[1] Nippon Med Coll, Dept Radiol, Bunkyo Ku, Tokyo 1138603, Japan
[2] GE Yokogawa Med Syst, Tokyo, Japan
关键词
magnetic resonance imaging; heart; steady-state free precession; interleaved data acquisition; flow artifact;
D O I
10.1016/j.compmedimag.2005.02.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Balanced steady-state free precession (SSFP) magnetic resonance (MR) imaging is feasible for cine cardiac images because of the high contrast between myocardium and blood pool and robustness to rapid blood flow. Nonetheless, the flow artifacts are often observed because of off-resonance effects and to in-flow effects of the blood flow. Although reshimming the gradients or readjusting the center frequency reduces the artifacts, the technique can be susceptible for respiratory and cardiac motion and operator-dependent. The purpose of this study is to use another MR imaging technique for the reduction in the flow artifacts in the heart: odd-even interleaved data acquisition in segmented balanced SSFP imaging. The flow artifacts in the ventricle, ghost outside the heart, and visualization of the myocardial border were visually compared between sequential and odd-even interleaved k-space data acquisitions in cine balanced SSFP cardiac MR imaging. The odd-even interleaved k-space data acquisition significantly reduced dark flow artifacts in the left ventricle, improved the visualization of the myocardial border, and was easily installed. This imaging technique should be applied to cine segmented balanced SSFP cardiac MR imaging. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:441 / 445
页数:5
相关论文
共 50 条
  • [21] Feasibility of MRI of the Fetal Heart with Balanced Steady-State Free Precession Sequence Along Fetal Body and Cardiac Planes
    Saleem, Sahar N.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (04) : 1208 - 1215
  • [22] Fourier Decomposition Pulmonary MRI Using a Variable Flip Angle Balanced Steady-State Free Precession Technique
    Corteville, D. M. R.
    Kjorstad, A.
    Henzler, T.
    Zoellner, F. G.
    Schad, L. R.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) : 1999 - 2004
  • [23] High spatial resolution brain functional MRI using submillimeter balanced steady-state free precession acquisitiona)
    Wu, Pei-Hsin
    Tsai, Ping-Huei
    Wu, Ming-Long
    Chuang, Tzu-Chao
    Shih, Yi-Yu
    Chung, Hsiao-Wen
    Huang, Teng-Yi
    MEDICAL PHYSICS, 2013, 40 (12)
  • [24] Clinical Applications of Cine Balanced Steady-State Free Precession MRI for the Evaluation of the Subarachnoid Spaces
    A.E. Li
    M.D. Wilkinson
    K.M. McGrillen
    M.A. Stoodley
    J.S. Magnussen
    Clinical Neuroradiology, 2015, 25 : 349 - 360
  • [25] Clinical Applications of Cine Balanced Steady-State Free Precession MRI for the Evaluation of the Subarachnoid Spaces
    Li, A. E.
    Wilkinson, M. D.
    McGrillen, K. M.
    Stoodley, M. A.
    Magnussen, J. S.
    CLINICAL NEURORADIOLOGY, 2015, 25 (04) : 349 - 360
  • [26] Dark flow artifacts with steady-state free precession cine MR technique: Causes and implications for cardiac MR imaging
    Li, W
    Storey, P
    Chen, Q
    Li, BSY
    Prasad, PV
    Edelman, RR
    RADIOLOGY, 2004, 230 (02) : 569 - 575
  • [27] Simultaneous Fat Suppression and Band Reduction with Large-Angle Multiple-Acquisition Balanced Steady-State Free Precession
    Quist, Brady
    Hargreaves, Brian A.
    Cukur, Tolga
    Morrell, Glen R.
    Gold, Garry E.
    Bangerter, Neal K.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (04) : 1004 - 1012
  • [28] Flow effects in balanced steady state free precession imaging
    Markl, M
    Alley, MT
    Elkins, CJ
    Pelc, NJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 892 - 903
  • [29] Profile-encoding reconstruction for multiple-acquisition balanced steady-state free precession imaging
    Ilicak, Efe
    Senel, Lutfi Kerem
    Biyik, Erdem
    Cukur, Tolga
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (04) : 1316 - 1329
  • [30] Fat and water separation in balanced steady-state free precession using the Dixon method
    Huang, TY
    Chung, HW
    Wang, FN
    Ko, CW
    Chen, CY
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) : 243 - 247