Reduction in flow artifacts by using interleaved data acquisition in segmented balanced steady-state free precession cardiac MRI

被引:3
|
作者
Amano, Y
Nozaki, A
Takahama, K
Kumazaki, T
机构
[1] Nippon Med Coll, Dept Radiol, Bunkyo Ku, Tokyo 1138603, Japan
[2] GE Yokogawa Med Syst, Tokyo, Japan
关键词
magnetic resonance imaging; heart; steady-state free precession; interleaved data acquisition; flow artifact;
D O I
10.1016/j.compmedimag.2005.02.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Balanced steady-state free precession (SSFP) magnetic resonance (MR) imaging is feasible for cine cardiac images because of the high contrast between myocardium and blood pool and robustness to rapid blood flow. Nonetheless, the flow artifacts are often observed because of off-resonance effects and to in-flow effects of the blood flow. Although reshimming the gradients or readjusting the center frequency reduces the artifacts, the technique can be susceptible for respiratory and cardiac motion and operator-dependent. The purpose of this study is to use another MR imaging technique for the reduction in the flow artifacts in the heart: odd-even interleaved data acquisition in segmented balanced SSFP imaging. The flow artifacts in the ventricle, ghost outside the heart, and visualization of the myocardial border were visually compared between sequential and odd-even interleaved k-space data acquisitions in cine balanced SSFP cardiac MR imaging. The odd-even interleaved k-space data acquisition significantly reduced dark flow artifacts in the left ventricle, improved the visualization of the myocardial border, and was easily installed. This imaging technique should be applied to cine segmented balanced SSFP cardiac MR imaging. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:441 / 445
页数:5
相关论文
共 50 条
  • [1] Artificial neural network for suppression of banding artifacts in balanced steady-state free precession MRI
    Kim, Ki Hwan
    Park, Sung-Hong
    MAGNETIC RESONANCE IMAGING, 2017, 37 : 139 - 146
  • [2] Flow artifacts in steady-state free precession cine imaging
    Storey, P
    Li, W
    Chen, Q
    Edelman, RR
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 115 - 122
  • [3] Spiral balanced steady-state free precession cardiac imaging
    Nayak, KS
    Hargreaves, BA
    Hu, BS
    Nishimura, DG
    Pauly, JM
    Meyer, CH
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1468 - 1473
  • [4] FMRI using balanced steady-state free precession (SSFP)
    Miller, Karla L.
    NEUROIMAGE, 2012, 62 (02) : 713 - 719
  • [5] Cardiac balanced steady-state free precession MRI at 0.35 T: a comparison study with 1.5 T
    Rashid, Shams
    Han, Fei
    Gao, Yu
    Sung, Kyunghyun
    Cao, Minsong
    Yang, Yingli
    Hu, Peng
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2018, 8 (07) : 627 - 636
  • [6] Spectrally selective imaging with wideband balanced steady-state free precession MRI
    Cukur, Tolga
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) : 1132 - 1141
  • [7] Noncontrast MRI Surveillance of Craniopharyngiomas Using a Balanced Steady-state Free Precession (bSSFP) Sequence
    Trinh, Kelly
    Tang, Michael
    White-Dzuro, Claire
    Lang, Min
    Buch, Karen
    Rincon, Sandra
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2025, 46 (01) : 136 - 140
  • [8] Fundamentals of balanced steady state free precession MRI
    Bieri, Oliver
    Scheffler, Klaus
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (01) : 2 - 11
  • [9] Balanced Steady-State Free Precession Cine MR Imaging in the Presence of Cardiac Devices: Value of Interleaved Radial Linear Combination Acquisition With Partial Dephasing
    Xiang, Jie
    Lamy, Jerome
    Lampert, Rachel
    Peters, Dana C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (03) : 782 - 791
  • [10] Single and double acquisition strategies for compensation of artifacts from eddy current and transient oscillation in balanced steady-state free precession
    Lee, Hyun-Soo
    Choi, Seung Hong
    Park, Sung-Hong
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (01) : 254 - 263