Small-Signal Behavior of a TES Under AC Bias

被引:12
作者
van der Kuur, Jan [1 ]
Gottardi, Luciano [1 ]
Parra Borderias, Maria [2 ]
Dirks, Bob [1 ]
de Korte, Piet [1 ]
Lindeman, Mark [1 ]
Khosropanah, Pourya [1 ]
den Hartog, Roland [1 ]
Hoevers, Henk [1 ]
机构
[1] SRON, NL-3584 CA Utrecht, Netherlands
[2] Univ Zaragoza, CSIC, Inst Ciencia Mat Aragon, E-50009 Zaragoza, Spain
关键词
D O I
10.1109/TASC.2010.2099092
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frequency domain multiplexing (FDM) is one of the candidates for the SQUID based readout of TES-based imaging microcalorimeter arrays for applications such as IXO, and imaging bolometer arrays for the SAFARI instrument on the Japanese SPICA space telescope. Usage of the TES as modulating element by applying an AC bias is an essential part of FDM. Within this framework the small signal characteristics of array pixels under both AC and DC bias have been measured. We will present a small signal model of the TES under AC bias, and apply the results to the measurements on an X-ray microcalorimeter.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 7 条
[1]   14-pixel, multiplexed array of gamma-ray microcalorimeters with 47 eV energy resolution at 103 keV [J].
Doriese, W. B. ;
Ullom, J. N. ;
Beall, J. A. ;
Duncan, W. D. ;
Ferreira, L. ;
Hilton, G. C. ;
Horansky, R. D. ;
Irwin, K. D. ;
Mates, J. A. B. ;
Reintsema, C. D. ;
Vale, L. R. ;
Xu, Y. ;
Zink, B. L. ;
Rabin, M. W. ;
Hoover, A. S. ;
Rudy, C. R. ;
Vo, D. T. .
APPLIED PHYSICS LETTERS, 2007, 90 (19)
[2]  
GOTTARDI L, 2008, J LOW TEMPERATURE PH, V151
[3]  
Irwin KD, 2005, TOP APPL PHYS, V99, P63
[4]   Demonstration of a multiplexer of dissipationless superconducting quantum interference devices [J].
Mates, J. A. B. ;
Hilton, G. C. ;
Irwin, K. D. ;
Vale, L. R. ;
Lehnert, K. W. .
APPLIED PHYSICS LETTERS, 2008, 92 (02)
[5]   Code-division SQUID multiplexing [J].
Niemack, M. D. ;
Beyer, J. ;
Cho, H. M. ;
Doriese, W. B. ;
Hilton, G. C. ;
Irwin, K. D. ;
Reintsema, C. D. ;
Schmidt, D. R. ;
Ullom, J. N. ;
Vale, L. R. .
APPLIED PHYSICS LETTERS, 2010, 96 (16)
[6]  
TAKEI Y, 2008, J LOW TEMPERATURE PH, V151
[7]   Performance of an x-ray microcalorimeter under ac biasing [J].
van der Kuur, J ;
de Korte, PAJ ;
Hoevers, HFC ;
Kiviranta, M ;
Seppä, H .
APPLIED PHYSICS LETTERS, 2002, 81 (23) :4467-4469