A Time-Frequency Approach for Cerebral Embolic Load Monitoring

被引:8
作者
Imaduddin, Syed M. [1 ,2 ]
LaRovere, Kerri L. [3 ]
Kussman, Barry D. [4 ]
Heldt, Thomas [1 ,2 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Inst Med Engn & Sci, Cambridge, MA 02139 USA
[2] MIT, Res Lab Elect, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[3] Boston Childrens Hosp, Dept Neurol, Boston, MA USA
[4] Boston Childrens Hosp, Dept Anesthesiol Crit Care & Pain Med, Boston, MA USA
关键词
Doppler effect; Ultrasonic imaging; Microsoft Windows; Catheterization; Monitoring; Training; Testing; Emboli; patient monitoring; stroke; time-frequency analysis; transcranial ultrasound; VENTRICULAR ASSIST DEVICE; TRANSCRANIAL DOPPLER; MICROEMBOLI; SUPPORT;
D O I
10.1109/TBME.2019.2927709
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: To enable reliable cerebral embolic load monitoring from high-intensity transient signals (HITS) recorded with single-channel transcranial Doppler (TCD) ultrasound. Methods: We propose a HITS detection and characterization method using a weighted-frequency Fourier linear combiner that estimates baseline Doppler signal power. An adaptive threshold is determined by examining the Doppler signal power variance about the baseline estimate, and HITS are extracted if their Doppler power exceeds this threshold. As signatures from multiple emboli may be superimposed, we analyze the detected HITS in the time-frequency (TF) domain to segment the signals into individual emboli. A logistic regression classification approach is employed to classify HITS into emboli or artifacts. Data were collected using a commercial TCD device with emboli-detection capabilities from 12 children undergoing mechanical circulatory support or cardiac catheterization. A subset of 696 HITS were reviewed, annotated, and split into training and testing sets for developing and evaluating the HITS classification algorithm. Results: The classifier yielded 98% and 96% sensitivity for 100% specificity on training and testing data, respectively. The TF approach decomposed 38% of candidate embolic signals into two or more embolic events that ultimately account for 69% of the overall embolic counts. Our processing pipeline resulted in highly accurate emboli identification and produced emboli counts that were lower (by a median of 64%) compared to the commercial ultrasound system's estimates. Significance: Using only single-channel, single-frequency Doppler ultrasound, the proposed method enables sensitive detection and segmentation of embolic signatures. Our approach paves the way toward accurate real-time cerebral emboli monitoring.
引用
收藏
页码:1007 / 1018
页数:12
相关论文
共 41 条
  • [11] Geryes M, 2015, I CON ADV BIOMED ENG, P89, DOI 10.1109/ICABME.2015.7323258
  • [12] Girault JM, 2007, INT CONF ACOUST SPEE, P409
  • [13] Gonzales R. C., 2002, Digital Image Processing
  • [14] Sequential Emboli Detection From Ultrasound Outpatient Data
    Guepie, Blaise Kevin
    Martin, Matthieu
    Lacrosaz, Victor
    Almar, Marilys
    Guibert, Benoit
    Delachartre, Philippe
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2019, 23 (01) : 334 - 341
  • [15] Imaduddin S. M., 2019, J ULTRASOUND MED S, V38, pS98
  • [16] Jensen J. A., 1996, Estimation of Blood Velocities Using Ultrasound: A Signal Processing Approach
  • [17] A polynomial based algorithm for detection of embolism
    Karahoca, Adem
    Tunga, M. Alper
    [J]. SOFT COMPUTING, 2015, 19 (01) : 167 - 177
  • [18] Patterns of Head Computed Tomography Abnormalities During Pediatric Extracorporeal Membrane Oxygenation and Association With Outcomes
    LaRovere, Kerri L.
    Vonberg, Frederick W.
    Prabhu, Sanjay P.
    Kapur, Kush
    Harini, Chellamani
    Garcia-Jacques, Rogelio
    Chao, Jessica H.
    Akhondi-Asl, Aliresa
    Thiagarajan, Ravi
    Tasker, Robert C.
    [J]. PEDIATRIC NEUROLOGY, 2017, 73 : 64 - 70
  • [19] Cerebral High-Intensity Transient Signals during Pediatric Cardiac Catheterization: A Pilot Study Using Transcranial Doppler Ultrasonography
    LaRovere, Kerri L.
    Kapur, Kush
    McElhinney, Doff B.
    Razumovsky, Alexander
    Kussman, Barry D.
    [J]. JOURNAL OF NEUROIMAGING, 2017, 27 (04) : 381 - 387
  • [20] QUANTIFICATION OF EMBOLIC SHOWERS USING RADIO-FREQUENCY BASED TCD ANALYSIS
    Lipperts, M. G. A.
    Sauren, L. D. C.
    Maessen, J. G.
    Hoeks, A. P. G.
    Mess, W. H.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (03) : 395 - 402