An automated dose verification software for brachytherapy

被引:8
作者
Wang, Xianliang [1 ,2 ]
Wang, Pei [2 ]
Li, Churong [2 ]
Wu, Zhangwen [1 ]
Gou, Chengjun [1 ]
Li, Jie [2 ]
Kang, Shengwei [2 ]
Hou, Qing [1 ]
机构
[1] Sichuan Univ, Inst Nucl Sci & Technol, Key Lab Radiat Phys & Technol, 24 South Sect 1,Yihuan Rd, Chengdu 610065, Sichuan, Peoples R China
[2] Sichuan Canc Hosp & Inst, Dept Radiat Oncol, Chengdu, Sichuan, Peoples R China
关键词
brachytherapy; dose verification; quality assurance; treatment planning system; CERVIX CANCER BRACHYTHERAPY; GEC-ESTRO; RECOMMENDATIONS; AAPM; PHYSICS; PARAMETERS; DOSIMETRY; TERMS;
D O I
10.5114/jcb.2018.79396
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To report an implementation method and the results of independent brachytherapy dose verification software (DVS). Material and methods: The DVS was developed based on Visual C++ and adopted a modular structure design. The DICOM RT files exported from a treatment planning system (TPS) were automatically loaded into the DVS. The DVS used the TG-43 formalism for dose calculation. A total of 15 cervical cancer patients who underwent brachytherapy were retrospectively selected to test the DVS. Dosimetric parameters and gamma analysis (0.1 cm, 5%) were used to evaluate the dose differences between the DVS and the TPS. Results: Compared with the TPS dose, the gamma pass rates of the dose calculated by the DVS were higher than 98%. For the clinical target volume (CTV), the dosimetric differences were less than 0.63% for D-90(%) and D-100%. For the bladder, rectum, and sigmoid, the agreement of D-0.1cc, D-1cc, and D-2cc were within a 0.78% level. Conclusions: With minimal human-computer interactions, the DVS can verify the accuracy of doses calculated by the TPS.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 50 条
  • [41] Development and comprehensive commissioning of an automated brachytherapy plan checker
    Simiele, Samantha J.
    Chen, Xiaoping
    Lee, Choonik
    Rosen, Benjamin S.
    Mikell, Justin K.
    Moran, Jean M.
    Prisciandaro, Joann, I
    [J]. BRACHYTHERAPY, 2020, 19 (03) : 355 - 361
  • [42] Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGER® radiochromic plastic
    Palmer, A. L.
    Di Pietro, P.
    Alobaidli, S.
    Issa, F.
    Doran, S.
    Bradley, D.
    Nisbet, A.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [43] The Implementation of the Gynaecological Groupe Europeen de Curietherapie - European Society for Therapeutic Radiology and Oncology Radiobiology Considerations in the Conversion of Low Dose Rate to Pulsed Dose Rate Treatment Schedules for Gynaecological Brachytherapy
    Baker, S.
    Pooler, A.
    Hendry, J.
    Davidson, S.
    [J]. CLINICAL ONCOLOGY, 2013, 25 (04) : 265 - 271
  • [44] High-Dose-Rate 192Ir Brachytherapy Dose Verification: A Phantom Study
    Nikoofar, Alireza
    Hoseinpour, Zohreh
    Mahdavi, Seied Rabi
    Hasanzadeh, Hadi
    Tavirani, Mostafa Rezaei
    [J]. IRANIAN JOURNAL OF CANCER PREVENTION, 2015, 8 (03)
  • [45] Effects of bladder distension on dose distribution of vaginal vault brachytherapy in patients with endometrial cancer
    Guler, Ozan C.
    Onal, Cem
    Acibuci, Ibrahim
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (04) : 371 - 376
  • [46] Optimum organ volume ranges for organs at risk dose in cervical cancer intracavitary brachytherapy
    Siavashpour, Zahra
    Aghamiri, Mahmoud Reza
    Jaberi, Ramin
    Manshadi, Hamid Reza Dehghan
    Ghaderi, Reza
    Kirisits, Christian
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2016, 8 (02) : 135 - 142
  • [47] Critical discussion of different dose-volume parameters for rectum and urethra in prostate brachytherapy
    Kirisits, Christian
    Goldner, Gregor
    Berger, Daniel
    Georg, Dietmar
    Poetter, Richard
    [J]. BRACHYTHERAPY, 2009, 8 (04) : 353 - 360
  • [48] On the Sensitivity of α/β Prediction to Dose Calculation Methodology in Prostate Brachytherapy
    Afsharpour, Hossein
    Walsh, Sean
    Fekete, Charles-Antoine Collins
    Vigneault, Eric
    Verhaegen, Frank
    Beaulieu, Luc
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 88 (02): : 345 - 350
  • [49] The influence of tissue composition uncertainty on dose distributions in brachytherapy
    Mann-Krzisnik, Dylan
    Verhaegen, Frank
    Enger, Shirin A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 126 (03) : 394 - 410
  • [50] A modified dose calculation formalism for electronic brachytherapy sources
    DeWerd, Larry A.
    Culberson, Wesley. S.
    Micka, John A.
    Simiele, Samantha J.
    [J]. BRACHYTHERAPY, 2015, 14 (03) : 405 - 408