An automated dose verification software for brachytherapy

被引:8
|
作者
Wang, Xianliang [1 ,2 ]
Wang, Pei [2 ]
Li, Churong [2 ]
Wu, Zhangwen [1 ]
Gou, Chengjun [1 ]
Li, Jie [2 ]
Kang, Shengwei [2 ]
Hou, Qing [1 ]
机构
[1] Sichuan Univ, Inst Nucl Sci & Technol, Key Lab Radiat Phys & Technol, 24 South Sect 1,Yihuan Rd, Chengdu 610065, Sichuan, Peoples R China
[2] Sichuan Canc Hosp & Inst, Dept Radiat Oncol, Chengdu, Sichuan, Peoples R China
关键词
brachytherapy; dose verification; quality assurance; treatment planning system; CERVIX CANCER BRACHYTHERAPY; GEC-ESTRO; RECOMMENDATIONS; AAPM; PHYSICS; PARAMETERS; DOSIMETRY; TERMS;
D O I
10.5114/jcb.2018.79396
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To report an implementation method and the results of independent brachytherapy dose verification software (DVS). Material and methods: The DVS was developed based on Visual C++ and adopted a modular structure design. The DICOM RT files exported from a treatment planning system (TPS) were automatically loaded into the DVS. The DVS used the TG-43 formalism for dose calculation. A total of 15 cervical cancer patients who underwent brachytherapy were retrospectively selected to test the DVS. Dosimetric parameters and gamma analysis (0.1 cm, 5%) were used to evaluate the dose differences between the DVS and the TPS. Results: Compared with the TPS dose, the gamma pass rates of the dose calculated by the DVS were higher than 98%. For the clinical target volume (CTV), the dosimetric differences were less than 0.63% for D-90(%) and D-100%. For the bladder, rectum, and sigmoid, the agreement of D-0.1cc, D-1cc, and D-2cc were within a 0.78% level. Conclusions: With minimal human-computer interactions, the DVS can verify the accuracy of doses calculated by the TPS.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 50 条
  • [11] Personalized Superficial HDR Brachytherapy-Dosimetric Verification of Dose Distribution with Lead Shielding of Critical Organs in the Head and Neck Region
    Zwierzchowski, Grzegorz
    Bieleda, Grzegorz
    Szymbor, Agata
    Boehlke, Marek
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (09):
  • [12] Dosimetric verification of the dose distribution in pulsed dose rate brachytherapy
    Lipinska, Joanna
    Zwierzchowski, Grzegorz
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2006, 11 (05) : 223 - 228
  • [13] An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributions
    Rivard, Mark J.
    Melhus, Christopher S.
    Granero, Domingo
    Perez-Calatayud, Jose
    Ballester, Facundo
    MEDICAL PHYSICS, 2009, 36 (06) : 1968 - 1975
  • [14] Time resolved dose rate distributions in brachytherapy
    Peppa, Vasiliki
    Pappas, Eleftherios P.
    Karaiskos, Pantelis
    Papagiannis, Panagiotis
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 : 13 - 19
  • [15] Experience of using MOSFET detectors for dose verification measurements in an end-to-end 192Ir brachytherapy quality assurance system
    Persson, Maria
    Nilsson, Josef
    Tedgren, Asa Carlsson
    BRACHYTHERAPY, 2018, 17 (01) : 227 - 233
  • [16] Brachytherapy dose calculation
    Ferre, M.
    Mailleux, H.
    Pierrat, N.
    Dejean, C.
    CANCER RADIOTHERAPIE, 2013, 17 (02): : 89 - 92
  • [17] Verification of SuperMC for Simulation of a High-Dose-Rate Brachytherapy Source
    Naeem, Hamza
    Wasaye, Muhammad Abdul
    Chen, Chaobin
    Zheng, Huaqing
    Hao, Lijuan
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 70 (12) : 1077 - 1082
  • [18] Film based verification of calculation algorithms used for brachytherapy planning-getting ready for upcoming challenges of MBDCA
    Zwierzchowski, Grzegorz
    Bieleda, Grzegorz
    Skowronek, Janusz
    Mazur, Magdalena
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2016, 8 (04) : 326 - 335
  • [19] Anthropomorphic phantom to investigate the bladder dose in gynecological high-dose-rate brachytherapy
    Silva, R. M. V.
    Belinato, W.
    Macedo, L. E.
    Souza, D. N.
    BRACHYTHERAPY, 2015, 14 (05) : 633 - 641
  • [20] Improved heterogeneity handling in the collapsed cone dose engine for brachytherapy
    Alpsten, Freja
    van Veelen, Bob
    Valdes-Cortez, Christian
    Berumen, Francisco
    Ahnesjo, Anders
    Tedgren, Asa Carlsson
    MEDICAL PHYSICS, 2024, : 585 - 595