An automated dose verification software for brachytherapy

被引:8
|
作者
Wang, Xianliang [1 ,2 ]
Wang, Pei [2 ]
Li, Churong [2 ]
Wu, Zhangwen [1 ]
Gou, Chengjun [1 ]
Li, Jie [2 ]
Kang, Shengwei [2 ]
Hou, Qing [1 ]
机构
[1] Sichuan Univ, Inst Nucl Sci & Technol, Key Lab Radiat Phys & Technol, 24 South Sect 1,Yihuan Rd, Chengdu 610065, Sichuan, Peoples R China
[2] Sichuan Canc Hosp & Inst, Dept Radiat Oncol, Chengdu, Sichuan, Peoples R China
关键词
brachytherapy; dose verification; quality assurance; treatment planning system; CERVIX CANCER BRACHYTHERAPY; GEC-ESTRO; RECOMMENDATIONS; AAPM; PHYSICS; PARAMETERS; DOSIMETRY; TERMS;
D O I
10.5114/jcb.2018.79396
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To report an implementation method and the results of independent brachytherapy dose verification software (DVS). Material and methods: The DVS was developed based on Visual C++ and adopted a modular structure design. The DICOM RT files exported from a treatment planning system (TPS) were automatically loaded into the DVS. The DVS used the TG-43 formalism for dose calculation. A total of 15 cervical cancer patients who underwent brachytherapy were retrospectively selected to test the DVS. Dosimetric parameters and gamma analysis (0.1 cm, 5%) were used to evaluate the dose differences between the DVS and the TPS. Results: Compared with the TPS dose, the gamma pass rates of the dose calculated by the DVS were higher than 98%. For the clinical target volume (CTV), the dosimetric differences were less than 0.63% for D-90(%) and D-100%. For the bladder, rectum, and sigmoid, the agreement of D-0.1cc, D-1cc, and D-2cc were within a 0.78% level. Conclusions: With minimal human-computer interactions, the DVS can verify the accuracy of doses calculated by the TPS.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 50 条
  • [1] Electromagnetic tracking for treatment verification in interstitial brachytherapy
    Bert, Christoph
    Kellermeier, Markus
    Tanderup, Kari
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2016, 8 (05) : 448 - 453
  • [2] A dose verification method for high-dose-rate brachytherapy treatment plans
    Kumar, Rajesh
    Sharma, S. D.
    Vijaykumar, C.
    Deshpande, Sudesh
    Sharma, P. K.
    Vandana, S.
    Philomena, A.
    Chilkulwar, Ravi H.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2008, 4 (04) : 173 - 177
  • [3] MRI-based treatment planning and dose delivery verification for intraocular melanoma brachytherapy
    Zoberi, Jacqueline Esthappan
    Garcia-Ramirez, Jose
    Hedrick, Samantha
    Rodriguez, Vivian
    Bertelsman, Carol G.
    Mackey, Stacie
    Hu, Yanle
    Gach, H. Michael
    Rao, P. Kumar
    Grigsby, Perry W.
    BRACHYTHERAPY, 2018, 17 (01) : 31 - 39
  • [4] A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system
    Austerlitz, C.
    Campos, C. A. T.
    MEDICAL PHYSICS, 2013, 40 (11)
  • [5] Verification of high-dose-rate brachytherapy treatment planning dose distribution using liquid-filled ionization chamber array
    Yoosuf, A. B. Mohamed
    Jeevanandam, Prakash
    Whitten, Glenn
    Workman, Geraldine
    McGarry, Conor K.
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2018, 10 (02) : 142 - 154
  • [6] Verification of dose distribution in high dose-rate brachytherapy for cervical cancer using a normoxic N-vinylpyrrolidone polymer gel dosimeter
    Watanabe, Yusuke
    Maeyama, Takuya
    Mizukami, Shinya
    Tachibana, Hidenobu
    Terazaki, Tsuyoshi
    Takei, Hideyuki
    Muraishi, Hiroshi
    Gomi, Tsutomu
    Hayashi, Shin-ichiro
    JOURNAL OF RADIATION RESEARCH, 2022, 63 (06) : 838 - 848
  • [7] Independent brachytherapy plan verification software: Improving efficacy and efficiency
    Damato, Antonio L.
    Devlin, Phillip M.
    Bhagwat, Mandar S.
    Buzurovic, Ivan
    Friesen, Scott
    Hansen, Jorgen L.
    Lee, Larissa J.
    Molodowitch, Christina
    Nguyen, Paul L.
    O'Farrell, Desmond A.
    Viswanathan, Akila N.
    Williams, Christopher L.
    Killoran, Joseph H.
    Cormack, Robert A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 113 (03) : 420 - 424
  • [8] Preliminary investigation of performance of thermoluminescent dosimeters for dose verification in brachytherapy
    D'Avino, V.
    Scarica, M.
    Ametrano, G.
    La Verde, G.
    Manti, L.
    Muto, P.
    Pugliese, M.
    Arrichiello, C.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2020, 43 (06):
  • [9] Brachytherapy dose-volume histogram commissioning with multiple planning systems
    Gossman, Michael S.
    Hancock, Samuel S.
    Kudchadker, Rajat J.
    Lundahl, Paul R.
    Cao, Minsong
    Melhus, Christopher S.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (02): : 110 - 120
  • [10] Monte Carlo dosimetry of high dose rate gynecologic interstitial brachytherapy
    Desbiens, Maxime
    D'Amours, Michel
    Afsharpour, Hossein
    Verhaegen, Frank
    Lavallee, Marie-Claude
    Thibault, Isabelle
    Vigneault, Eric
    Beaulieu, Luc
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 425 - 429