Validity of a new contact mat system for evaluating vertical jump

被引:4
作者
Borges Junior, Noe Gomes [1 ]
Borges, Lucas [2 ]
Dias, Jonathan Ache
Wentz, Marcelo Diederichs
da Silva Mattos, Daniela Junckes
Petry, Raquel
Domenech, Susana Cristina
机构
[1] Univ Estado Santa Catarina, LABIN CEFID, Dept Ciencias Saude, BR-88080350 Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Florianopolis, SC, Brazil
来源
MOTRIZ-REVISTA DE EDUCACAO FISICA | 2011年 / 17卷 / 01期
关键词
Instrumentation; Validity of tests; Biomechanics; HEIGHT; POWER; RELIABILITY; PERFORMANCE; FORCE;
D O I
10.5016/1980-6574.2011v17n1p26
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The purpose of this study was to verify the validity of the flight and ground contact time measurement of a contact mat, SaltoBras (SB), comparing it to an oscilloscope (OS) and to a force plate (FP). For that, the SB was placed upon a FP. At first, four male and two female performed 15 jumps on the SB and the flight times were obtained. After, they performed six consecutive jumps and the ground contact times were obtained. SB software was valid in comparison with the OS, but underestimated the flight (similar to 0.30 %) and ground contact (similar to 1.01 %) time measurements when comparing it to the FP. Despite the differences, the error found between SB and FP was systematic, and two prediction equations were defined and added to the software for correction. The results suggest that SB is a valid instrument for the evaluation of vertical jump.
引用
收藏
页码:26 / 32
页数:7
相关论文
共 28 条
[1]  
Aragon-Vargas L. F., 2000, Measurement in Physical Education and Exercise Science, V4, P215, DOI 10.1207/S15327841MPEE0404_2
[2]   A comparison of methods for analyzing drop jump performance [J].
Baca, A .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1999, 31 (03) :437-442
[3]   A SIMPLE METHOD FOR MEASUREMENT OF MECHANICAL POWER IN JUMPING [J].
BOSCO, C ;
LUHTANEN, P ;
KOMI, PV .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1983, 50 (02) :273-282
[4]  
Cordova ML, 1996, J ATHL TRAINING, V31, P342
[5]   Physical characteristics that predict vertical jump performance in recreational male athletes [J].
Davis, DS ;
Briscoe, DA ;
Markowski, CT ;
Saville, SE ;
Taylor, CJ .
PHYSICAL THERAPY IN SPORT, 2003, 4 (04) :167-174
[6]  
de C N Sacco I., 2004, REV BRAS MED ESPORTE, V10, P453
[7]   Validity and reliability of the Newtest Powertimer 300-series® testing system [J].
Enoksen, Eystein ;
Tonnessen, Espen ;
Shalfawi, Shaher .
JOURNAL OF SPORTS SCIENCES, 2009, 27 (01) :77-84
[8]   The validation of a new method that measures contact and flight times during vertical jump [J].
García-López, J ;
Peleteiro, J ;
Rodgríguez-Marroyo, JA ;
Morante, JC ;
Herrero, JA ;
Villa, JG .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2005, 26 (04) :294-302
[9]   Neuromechanical strategies employed to increase jump height during the initiation of the squat jump [J].
Hasson, CJ ;
Dugan, EL ;
Doyle, TLA ;
Humphries, B ;
Newton, RU .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2004, 14 (04) :515-521
[10]   Reliability of power in physical performance tests [J].
Hopkins, WG ;
Schabort, EJ ;
Hawley, JA .
SPORTS MEDICINE, 2001, 31 (03) :211-234