Dual- and single-shot susceptibility ratio measurements with circular polarizations in second-harmonic generation microscopy

被引:9
|
作者
Golaraei, Ahmad [1 ,2 ,3 ]
Kontenis, Lukas [4 ,5 ]
Karunendiran, Abiramy [6 ,7 ]
Stewart, Bryan A. [6 ,7 ]
Barzda, Virginijus [2 ,3 ,5 ]
机构
[1] Univ Hlth Network, Princess Margaret Canc Centre, Toronto, ON, Canada
[2] Univ Toronto, Dept Phys, Toronto, ON, Canada
[3] Univ Toronto Mississauga, Dept Chem & Phys Sci, 3359 Mississauga Rd North, Mississauga, ON L5L 1C6, Canada
[4] Light Convers, Vilnius, Lithuania
[5] Vilnius Univ, Laser Res Ctr, Fac Phys, Vilnius, Lithuania
[6] Univ Toronto Mississauga, Dept Biol, Mississauga, ON, Canada
[7] Univ Toronto, Dept Cell & Syst Biol, Toronto, ON, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
muscle; nonlinear optical polarimetry; second-harmonic generation microscopy; second-order susceptibility; HARMONIC-GENERATION; IN-VIVO; COLLAGEN; MYOSIN; TISSUE; SCATTERING; POLARITY; VISUALIZATION; ORGANIZATION; ORIENTATION;
D O I
10.1002/jbio.201960167
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polarization-resolved second-harmonic generation (P-SHG) microscopy is a technique capable of characterizing nonlinear optical properties of noncentrosymmetric biomaterials by extracting the nonlinear susceptibility tensor components ratio chi zzz 2 '/chi zxx 2 ', with z-axis parallel and x-axis perpendicular to the C-6 symmetry axis of molecular fiber, such as a myofibril or a collagen fiber. In this paper, we present two P-SHG techniques based on incoming and outgoing circular polarization states for a fast extraction of chi zzz 2 '/chi zxx 2 ': A dual-shot configuration where the SHG circular anisotropy generated using incident right- and left-handed circularly-polarized light is measured; and a single-shot configuration for which the SHG circular anisotropy is measured using only one incident circular polarization state. These techniques are used to extract the chi zzz 2 '/chi zxx 2 ' of myosin fibrils in the body wall muscles of Drosophila melanogaster larva. The results are in good agreement with values obtained from the double Stokes-Mueller polarimetry. The dual- and single-shot circular anisotropy measurements can be used for fast imaging that is independent of the in-plane orientation of the sample. They can be used for imaging of contracting muscles, or for high throughput imaging of large sample areas.
引用
收藏
页数:9
相关论文
共 2 条
  • [1] Circular dichroism second-harmonic generation microscopy probes the polarity distribution of collagen fibrils
    Schmeltz, Margaux
    Teulon, Claire
    Pinsard, Maxime
    Hansen, Uwe
    Alnawaiseh, Maged
    Ghoubay, Djida
    Borderie, Vincent
    Mosser, Gervaise
    Aime, Carole
    Legare, Francois
    Latour, Gael
    Schanne-Klein, Marie-Claire
    OPTICA, 2020, 7 (11): : 1469 - 1476
  • [2] Single-cell screening and quantification of transcripts in cancer tissues by second-harmonic generation microscopy
    Liu, Jing
    Damayanti, Nur P.
    Cho, Il-Hoon
    Polar, Yesim
    Badve, Sunil
    Irudayaraj, Joseph M. K.
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (09)