Power System Adequacy Assessment with Load Redistribution Attacks

被引:0
作者
Xiang, Yingmeng [1 ]
Ding, Zhilu [2 ]
Wang, Lingfeng [1 ]
机构
[1] Univ Wisconsin, Dept Elect Engn & Comp Sci, Milwaukee, WI 53211 USA
[2] Univ Toledo, Toledo, OH 43606 USA
来源
2015 IEEE POWER & ENERGY SOCIETY INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT) | 2015年
关键词
Cybersecurity; adequacy assessment; smart grid; false data injection attack; bilevel optimization; cyber-physical systems; DATA INJECTION ATTACKS;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The wider deployment of advanced information and control technologies in the smart grid makes the power grid more vulnerable to cyber attacks such as false data injection attacks. However, the work on the long-term statistical impact of these attacks on the power grid adequacy is rather limited. In this study a novel adequacy evaluation procedure incorporating the load redistribution (LR) attack is proposed. The procedure takes into consideration the physical failures and the bilevel model representing the LR attack. The simulation is conducted based on Monte Carlo simulation (MCS) using Matlab and CPLEX. The influences of the time of attacks, the attack level, the defense level and the line transmission capacity are investigated. It is concluded that the cyber defense level is critical to the power system adequacy, and cyber issues need to be considered in the planning of the power grid.
引用
收藏
页数:5
相关论文
共 14 条
  • [1] Impact of WAMS Malfunction on Power System Reliability Assessment
    Aminifar, Farrokh
    Fotuhi-Firuzabad, Mahmud
    Shahidehpour, Mohammad
    Safdarian, Amir
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (03) : 1302 - 1309
  • [2] [Anonymous], 1979, IEEE T POWER AP SYST, V98, P2047, DOI 10.1109/TPAS.1979.319398
  • [3] Graphical Methods for Defense Against False-Data Injection Attacks on Power System State Estimation
    Bi, Suzhi
    Zhang, Ying Jun
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2014, 5 (03) : 1216 - 1227
  • [4] Billinton R., 1994, RELIABILITY ASSESSME
  • [5] Toward a framework for managing information security for an electric power utility - CIGRE experiences
    Ericsson, Goran N.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (03) : 1461 - 1469
  • [6] Toward a Comprehensive Model of Large-Scale DFIG-Based Wind Farms in Adequacy Assessment of Power Systems
    Ghaedi, Amir
    Abbaspour, Ali
    Fotuhi-Firuzabad, Mahmud
    Moeini-Aghtaie, Moein
    [J]. IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2014, 5 (01) : 55 - 63
  • [7] Hao XH, 2012, INT CONF SMART GRID, P25, DOI 10.1109/SmartGridComm.2012.6485954
  • [8] Detecting False Data Injection Attacks on Power Grid by Sparse Optimization
    Liu, Lanchao
    Esmalifalak, Mohammad
    Ding, Qifeng
    Emesih, Valentine A.
    Han, Zhu
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2014, 5 (02) : 612 - 621
  • [9] Local Load Redistribution Attacks in Power Systems With Incomplete Network Information
    Liu, Xuan
    Li, Zuyi
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2014, 5 (04) : 1665 - 1676
  • [10] False Data Injection Attacks against State Estimation in Electric Power Grids
    Liu, Yao
    Ning, Peng
    Reiter, Michael K.