Wearable Inertial Measurement Units for Assessing Gait in Real-World Environments

被引:55
作者
Renggli, David [1 ]
Graf, Christina [1 ]
Tachatos, Nikolaos [1 ]
Singh, Navrag [2 ]
Meboldt, Mirko [1 ]
Taylor, William R. [2 ]
Stieglitz, Lennart [3 ]
Schmid Daners, Marianne [1 ]
机构
[1] Swiss Fed Inst Technol, Prod Dev Grp Zurich, Dept Mech & Proc Engn, Zurich, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomech, Dept Hlth Sci & Technol, Zurich, Switzerland
[3] Univ Hosp Zurich, Dept Neurosurg, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
natural walking patterns; gait analysis; IMU sensors; ZurichMOVE; non-controlled settings; real-world environment; walking disorder; hydrocephalus; NORMAL-PRESSURE HYDROCEPHALUS; SPATIOTEMPORAL PARAMETERS; VARIABILITY; RELIABILITY; PREVALENCE; DIAGNOSIS; DISEASE; SYSTEM; YOUNG;
D O I
10.3389/fphys.2020.00090
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Background Walking patterns can provide important indications of a person's health status and be beneficial in the early diagnosis of individuals with a potential walking disorder. For appropriate gait analysis, it is critical that natural functional walking characteristics are captured, rather than those experienced in artificial or observed settings. To better understand the extent to which setting influences gait patterns, and particularly whether observation plays a varying role on subjects of different ages, the current study investigates to what extent people walk differently in lab versus real-world environments and whether age dependencies exist. Methods The walking patterns of 20 young and 20 elderly healthy subjects were recorded with five wearable inertial measurement units (ZurichMOVE sensors) attached to both ankles, both wrists and the chest. An automated detection process based on dynamic time warping was developed to efficiently identify the relevant sequences. From the ZurichMOVE recordings, 15 spatio-temporal gait parameters were extracted, analyzed and compared between motion patterns captured in a controlled lab environment (10 m walking test) and the non-controlled ecologically valid real-world environment (72 h recording) in both groups. Results Several parameters (Cluster A) showed significant differences between the two environments for both groups, including an increased outward foot rotation, step width, number of steps per 180 degrees turn, stance to swing ratio, and cycle time deviation in the real-world. A number of parameters (Cluster B) showed only significant differences between the two environments for elderly subjects, including a decreased gait velocity (p = 0.0072), decreased cadence (p = 0.0051) and increased cycle time (p = 0.0051) in real-world settings. Importantly, the real-world environment increased the differences in several parameters between the young and elderly groups. Conclusion Elderly test subjects walked differently in controlled lab settings compared to their real-world environments, which indicates the need to better understand natural walking patterns under ecologically valid conditions before clinically relevant conclusions can be drawn on a subject's functional status. Moreover, the greater inter-group differences in real-world environments seem promising regarding the sensitive identification of subjects with indications of a walking disorder.
引用
收藏
页数:13
相关论文
共 46 条
[11]   Gait Event Detection in Controlled and Real-Life Situations: Repeated Measures From Healthy Subjects [J].
Figueiredo, Joana ;
Felix, Paulo ;
Costa, Luis ;
Moreno, Juan C. ;
Santos, Cristina P. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2018, 26 (10) :1945-1956
[12]   The diagnosis and treatment of idiopathic normal pressure hydrocephalus [J].
Gallia, Gary L. ;
Rigamonti, Daniele ;
Williams, Michael A. .
NATURE CLINICAL PRACTICE NEUROLOGY, 2006, 2 (07) :375-381
[13]   Towards clinical application: Repetitive sensor position re-calibration for improved reliability of gait parameters [J].
Hamacher, Daniel ;
Hamacher, Dennis ;
Taylor, William R. ;
Singh, Navrag B. ;
Schega, Lutz .
GAIT & POSTURE, 2014, 39 (04) :1146-1148
[14]   Benchmarking Foot Trajectory Estimation Methods for Mobile Gait Analysis [J].
Hannink, Julius ;
Ollenschlaeger, Malte ;
Kluge, Felix ;
Roth, Nils ;
Klucken, Jochen ;
Eskofier, Bjoern M. .
SENSORS, 2017, 17 (09)
[15]   Idiopathic normal, pressure hydrocephalus: A systematic review of diagnosis and outcome [J].
Hebb, AO ;
Cusimano, MD .
NEUROSURGERY, 2001, 49 (05) :1166-1184
[16]   Analyses of Gait Parameters of Younger and Older Adults During (Non-)Isometric Virtual Walking [J].
Janeh, Omar ;
Bruder, Gerd ;
Steinicke, Frank ;
Gulberti, Alessandro ;
Poetter-Nerger, Monika .
IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2018, 24 (10) :2663-2674
[17]   Prevalence of idiopathic normal-pressure hydrocephalus [J].
Jaraj, Daniel ;
Rabiei, Katrin ;
Marlow, Thomas ;
Jensen, Christer ;
Skoog, Ingmar ;
Wikkelso, Carsten .
NEUROLOGY, 2014, 82 (16) :1449-1454
[18]   Gait event detection using linear accelerometers or angular velocity transducers in able-bodied and spinal-cord injured individuals [J].
Jasiewicz, Jan M. ;
Allum, John H. J. ;
Middleton, James W. ;
Barriskill, Andrew ;
Condie, Peter ;
Purcell, Brendan ;
Li, Raymond Che Tin .
GAIT & POSTURE, 2006, 24 (04) :502-509
[19]   Is gait variability reliable? An assessment of spatio-temporal parameters of gait variability during continuous overground walking [J].
Koenig, N. ;
Singh, N. B. ;
von Beckerath, J. ;
Janke, L. ;
Taylor, W. R. .
GAIT & POSTURE, 2014, 39 (01) :615-617
[20]   Revealing the quality of movement: A meta-analysis review to quantify the thresholds to pathological variability during standing and walking [J].
Konig, N. ;
Taylor, W. R. ;
Baumann, C. R. ;
Wenderoth, N. ;
Singh, N. B. .
NEUROSCIENCE AND BIOBEHAVIORAL REVIEWS, 2016, 68 :111-119