摘要
Introduction: Intraoperative fluoroscopy can be easily used because patients are placed in the supine position during total hip arthroplasty via direct anterior approach (DAA-THA) to reduce complications. However, the cumulative level of radiation exposure by intraoperative fluoroscopy increases as the annual number of cases increases, increasing the risk of influencing the health of both the patients and medical workers. The objective of the study was to compare the radiation exposure time of DAA-THA with osteosynthesis and to determine if the level of radiation exposure exceeded safety limits. Material and methods: DAA-THA was performed in 313 patients between January 2016 and July 2018 and 60 patients with proximal femoral fracture were treated with osteosynthesis. The intraoperative fluoroscopy time was retrospectively surveyed and compared between these two groups. A total of eight surgeons operated DAA-THA employing the same procedure using a traction table. A total of nine surgeons operated osteosynthesis and fluoroscopy was appropriately used during reduction and implant insertion. Results: The mean operative time of DAA-THA was 103.3 min and that of osteosynthesis was 83.3 min, showing a significant difference (p < 0.05). The mean intraoperative fluoroscopy time was 0.83 min (SD +/- 0.68) in DAA-THA and 8.91 min (SD +/- 8.34) in osteosynthesis showing a significant difference (p < 0.05). Conclusions: The intraoperative exposure level was significantly lower and the fluoroscopy time was significantly shorter in DAA-THA than in osteosynthesis for proximal femoral fracture. It was clarified that the annual cumulative radiation exposure level in DAA-THA does not exceed the tissue dose limit.
引用
收藏
页数:5
相关论文
共 25 条
[1]  
[Anonymous], 2010, Cochrane Database Syst Rev
[2]   Comparison of Minimally Invasive Direct Anterior Versus Posterior Total Hip Arthroplasty Based on Inflammation and Muscle Damage Markers [J].
Bergin, Patrick F. ;
Doppelts, Jason D. ;
Kephart, Curtis J. ;
Benke, Michael T. ;
Graeter, James H. ;
Holmes, Andrew S. ;
Haleem-Smith, Hana ;
Tuan, Rocky S. ;
Unger, Anthony S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (15) :1392-1398
[3]   Total hip arthroplasty versus hemiarthroplasty for displaced femoral neck fractures in the healthy elderly: a meta-analysis and systematic review of randomized trials [J].
Burgers, Paul T. P. W. ;
Van Geene, Arnoud R. ;
Van den Bekerom, Michel P. J. ;
Van Lieshout, Esther M. M. ;
Blom, Bastiaan ;
Aleem, Ilyas S. ;
Bhandari, M. ;
Poolman, Rudolf W. .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (08) :1549-1560
[4]   Dose-area product measurements in a range of common orthopaedic procedures and their possible use in establishing local diagnostic reference levels [J].
Crawley, MT ;
Rogers, AT .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (871) :740-744
[5]   Patient Radiation Exposure During Fluoro-Assisted Direct Anterior Approach Total Hip Arthroplasty [J].
Curtin, Brian M. ;
Armstrong, Lucas C. ;
Bucker, Brandon T. ;
Odum, Susan M. ;
Jiranek, William A. .
JOURNAL OF ARTHROPLASTY, 2016, 31 (06) :1218-1221
[6]   Evaluation of thyroid shields for reduction of radiation exposure to orthopaedic surgeons [J].
Dewey, P ;
Incoll, I .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1998, 68 (09) :635-636
[7]   Exposure of the surgeon to radiation during surgery [J].
Fuchs, M ;
Schmid, A ;
Eiteljorge, T ;
Modler, M ;
Sturmer, KM .
INTERNATIONAL ORTHOPAEDICS, 1998, 22 (03) :153-156
[8]  
Giordano BD, 2011, J BONE JOINT SURG AM, V93A, P1183, DOI 10.2106/JBJS.J.01328
[9]   Occupational eye dose in interventional cardiology procedures [J].
Haga, Yoshihiro ;
Chida, Koichi ;
Kaga, Yuji ;
Sota, Masahiro ;
Meguro, Taiichiro ;
Zuguchi, Masayuki .
SCIENTIFIC REPORTS, 2017, 7
[10]   Safety in early experience with a direct anterior approach using fluoroscopic guidance with manual leg control for primary total hip arthroplasty: a consecutive one hundred and twenty case series [J].
Homma, Yasuhiro ;
Baba, Tomonori ;
Kobayashi, Hideo ;
Desroches, Asuka ;
Ozaki, Yu ;
Ochi, Hironori ;
Matsumoto, Mikio ;
Yuasa, Takahito ;
Kaneko, Kazuo .
INTERNATIONAL ORTHOPAEDICS, 2016, 40 (12) :2487-2494