Magnetic Resonance Imaging of Water Content and Flow Processes in Natural Soils by Pulse Sequences with Ultrashort Detection

被引:2
|
作者
Haber-Pohlmeier, Sabina [1 ]
Caterina, David [2 ,3 ]
Bluemich, Bernhard [4 ]
Pohlmeier, Andreas [2 ]
机构
[1] Univ Stuttgart, Inst Modelling Hydraul & Environm Syst, Pfaffenwaldring 61, D-70569 Stuttgart, Germany
[2] Res Ctr Julich, Inst Bio & Geosci Agrosphere IBG 3, D-52425 Julich, Germany
[3] Univ Liege, Fac Sci Appl, Dept UEE, B-4000 Liege, Belgium
[4] Rhein Westfal TH Aachen, Inst Tech & Macromol Chem, Worringer Weg 2, D-52074 Aachen, Germany
来源
MOLECULES | 2021年 / 26卷 / 17期
关键词
magnetic resonance imaging; natural soil material; fast relaxation times; water content; water flow; POROUS-MEDIA; TRACER TRANSPORT; MRI; FLUIDS; ROCKS; FIELD;
D O I
10.3390/molecules26175130
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Magnetic resonance imaging is a valuable tool for three-dimensional mapping of soil water processes due to its sensitivity to the substance of interest: water. Since conventional gradient- or spin-echo based pulse sequences do not detect rapidly relaxing fractions of water in natural porous media with transverse relaxation times in the millisecond range, pulse sequences with ultrafast detection open a way out. In this work, we compare a spin-echo multislice pulse sequence with ultrashort (UTE) and zero-TE (ZTE) sequences for their suitability to map water content and its changes in 3D in natural soil materials. Longitudinal and transverse relaxation times were found in the ranges around 80 ms and 1 to 50 ms, respectively, so that the spin echo sequence misses larger fractions of water. In contrast, ZTE and UTE could detect all water, if the excitation and detection bandwidths were set sufficiently broad. More precisely, with ZTE we could map water contents down to 0.1 cm(3)/cm(3). Finally, we employed ZTE to monitor the development of film flow in a natural soil core with high temporal resolution. This opens the route for further quantitative imaging of soil water processes.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] MAGNETIC-RESONANCE-IMAGING OF KNEE MENISCI - COMPARISON OF SPIN-ECHO PULSE SEQUENCES
    EVANCHO, AM
    FAJMAN, WA
    STILES, RG
    BRUNNER, MC
    PETERSON, J
    FLEMING, L
    INVESTIGATIVE RADIOLOGY, 1990, 25 (11) : 1224 - 1227
  • [32] Magnetic resonance imaging with fluid-attenuated inversion recovery pulse sequences in MELAS syndrome
    Kimura, M
    Hasegawa, Y
    Yasuda, K
    Sejima, H
    Inoue, M
    Yamaguchi, S
    Ando, Y
    Ohno, S
    PEDIATRIC RADIOLOGY, 1997, 27 (02) : 153 - 154
  • [33] Magnetic resonance imaging with fluid-attenuated inversion recovery pulse sequences in MELAS syndrome
    Masahiko Kimura
    Yuki Hasegawa
    Kenji Yasuda
    Hitoshi Sejima
    Makoto Inoue
    Seiji Yamaguchi
    Yukinori Ando
    Shigeru Ohno
    Pediatric Radiology, 1997, 27 : 153 - 154
  • [34] Influence of plasticity on unfrozen water content of frozen soils as determined by nuclear magnetic resonance
    Kong, Lingming
    Wang, Yansong
    Sun, Wenjing
    Qi, Jilin
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2020, 172
  • [35] BULK FLOW MODEL FOR MULTISLICE MAGNETIC-RESONANCE IMAGING SEQUENCES WITH PHANTOM VALIDATION
    MEYER, CR
    WILLIAMS, DM
    MEDICAL PHYSICS, 1988, 15 (01) : 1 - 6
  • [36] Detection of hepatic VX2 carcinomas with ferucarbotran-enhanced magnetic resonance imaging in rabbits: Comparison of nine pulse sequences
    Kim, Seong Hyun
    Choi, Dongil
    Lim, Hyo K.
    Kim, Min Ju
    Jang, Kyung Mi
    Kim, Seung Hoon
    Lee, Won Jae
    Lee, Jongmee
    Jeon, Yong Hwan
    Lim, Jae Hoon
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 59 (03) : 413 - 423
  • [37] Measurement of an oil-water flow using magnetic resonance imaging
    Lakshmanan, Susithra
    Maru, Wessenu A.
    Holland, Daniel J.
    Mantle, Mick D.
    Sederman, Andy J.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2017, 53 : 161 - 171
  • [38] Magnetic resonance imaging (MRI) of articular cartilage of the knee using ultrashort echo time (uTE) sequences with spiral acquisition
    Goto, Hajimu
    Fujii, Masahiko
    Iwama, Yuki
    Aoyama, Nobukazu
    Ohno, Yoshiharu
    Sugimura, Kazuro
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (03) : 318 - 323
  • [39] Magnetic resonance imaging (MRI) study of the water content and transport in rat lenses
    Dobretsov, Egor A.
    Snytnikova, Olga A.
    Koptyug, Igor V.
    Kaptein, Robert
    Tsentalovich, Yuri P.
    EXPERIMENTAL EYE RESEARCH, 2013, 113 : 162 - 171
  • [40] Magnetic resonance imaging of lung water content and distribution in term and preterm infants
    Adams, EW
    Counsell, SJ
    Hajnal, JV
    Cox, PN
    Kennea, NL
    Thornton, AS
    Bryan, AC
    Edwards, AD
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (03) : 397 - 402