Magnetic Resonance Imaging of Water Content and Flow Processes in Natural Soils by Pulse Sequences with Ultrashort Detection

被引:2
|
作者
Haber-Pohlmeier, Sabina [1 ]
Caterina, David [2 ,3 ]
Bluemich, Bernhard [4 ]
Pohlmeier, Andreas [2 ]
机构
[1] Univ Stuttgart, Inst Modelling Hydraul & Environm Syst, Pfaffenwaldring 61, D-70569 Stuttgart, Germany
[2] Res Ctr Julich, Inst Bio & Geosci Agrosphere IBG 3, D-52425 Julich, Germany
[3] Univ Liege, Fac Sci Appl, Dept UEE, B-4000 Liege, Belgium
[4] Rhein Westfal TH Aachen, Inst Tech & Macromol Chem, Worringer Weg 2, D-52074 Aachen, Germany
来源
MOLECULES | 2021年 / 26卷 / 17期
关键词
magnetic resonance imaging; natural soil material; fast relaxation times; water content; water flow; POROUS-MEDIA; TRACER TRANSPORT; MRI; FLUIDS; ROCKS; FIELD;
D O I
10.3390/molecules26175130
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Magnetic resonance imaging is a valuable tool for three-dimensional mapping of soil water processes due to its sensitivity to the substance of interest: water. Since conventional gradient- or spin-echo based pulse sequences do not detect rapidly relaxing fractions of water in natural porous media with transverse relaxation times in the millisecond range, pulse sequences with ultrafast detection open a way out. In this work, we compare a spin-echo multislice pulse sequence with ultrashort (UTE) and zero-TE (ZTE) sequences for their suitability to map water content and its changes in 3D in natural soil materials. Longitudinal and transverse relaxation times were found in the ranges around 80 ms and 1 to 50 ms, respectively, so that the spin echo sequence misses larger fractions of water. In contrast, ZTE and UTE could detect all water, if the excitation and detection bandwidths were set sufficiently broad. More precisely, with ZTE we could map water contents down to 0.1 cm(3)/cm(3). Finally, we employed ZTE to monitor the development of film flow in a natural soil core with high temporal resolution. This opens the route for further quantitative imaging of soil water processes.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Magnetic resonance imaging of the knee with ultrashort TE pulse sequences
    Gatehouse, PD
    Thomas, RW
    Robson, MD
    Hamilton, G
    Herlihy, AH
    Bydder, GM
    MAGNETIC RESONANCE IMAGING, 2004, 22 (08) : 1061 - 1067
  • [2] Magnetic resonance imaging of periosteum with ultrashort TE pulse sequences
    Reichert, ILH
    Benjamin, M
    Gatehouse, PD
    Chappell, KE
    Holmes, J
    He, TG
    Bydder, GM
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (01) : 99 - 107
  • [3] Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences
    Reichert, ILH
    Robson, MD
    Gatehouse, PD
    He, TG
    Chappell, KE
    Holmes, J
    Girgis, S
    Bydder, GM
    MAGNETIC RESONANCE IMAGING, 2005, 23 (05) : 611 - 618
  • [4] Magnetic resonance imaging of the liver with ultrashort TE (UTE) pulse sequences
    Chappell, KE
    Patel, N
    Gatehouse, PD
    Main, J
    Puri, BK
    Taylor-Robinson, SD
    Bydder, GM
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (06) : 709 - 713
  • [5] Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: Technical considerations
    Tyler, Damian J.
    Robson, Matthew D.
    Henkelman, R. Mark
    Young, Ian R.
    Bydder, Graeme M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (02) : 279 - 289
  • [6] Magnetic resonance imaging of entheses using ultrashort TE (UTE) pulse sequences
    Benjamin, Michael
    Bydder, Graeme M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (02) : 381 - 389
  • [7] Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequences
    Robson, MD
    Benjamin, M
    Gishen, P
    Bydder, GM
    CLINICAL RADIOLOGY, 2004, 59 (08) : 727 - 735
  • [8] Magnetic resonance imaging of the normal pituitary gland using ultrashort TE (UTE) pulse sequences (REV 1.0)
    Portman, Olivia
    Flemming, Stephen
    Cox, Jeremy P. D.
    Johnston, Desmond G.
    Bydder, Graeme M.
    NEURORADIOLOGY, 2008, 50 (03) : 213 - 220
  • [9] Magnetic resonance imaging of the normal pituitary gland using ultrashort TE (UTE) pulse sequences (REV 1.0)
    Olivia Portman
    Stephen Flemming
    Jeremy P. D. Cox
    Desmond G. Johnston
    Graeme M. Bydder
    Neuroradiology, 2008, 50 : 213 - 220
  • [10] Quantification of Myocardial Blood Flow Using Magnetic Resonance Imaging with Different accelerated Pulse Sequences
    Weber, S.
    Kreitner, K. -F.
    Schreiber, L. M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 621 - +