Safety and effectiveness of gadolinium-enhanced multi-detector row spiral CT angiography of the chest: Preliminary results in 37 patients with contra-indications to iodinated contrast agents

被引:47
作者
Remy-Jardin, M
Dequiedt, P
Ertzbischoff, O
Tillie-Leblond, I
Bruzzi, J
Duhamel, A
Remy, J
机构
[1] Univ Ctr Lille, Hosp Calmette, Dept Radiol, F-59037 Lille, France
[2] Schering SA, Lys Lez Lannoy, France
[3] Univ Lille, Dept Med Stat, Lille, France
关键词
D O I
10.1148/radiol.2353040734
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively evaluate the safety and effectiveness of gadolinium-enhanced multi-detector row spiral computed tomographic (CT) angiography of the pulmonary circulation by using two gadolinium doses in patients with contraindications to iodinated contrast agents. MATERIALS AND METHODS: Study was approved by the Ethics Committee, and written informed consent was obtained. Thirty-seven patients (20 men, 17 women) with contraindications to iodinated contrast agents (allergic reactions, n = 27; impaired renal function, n = 10) underwent CT angiography of the pulmonary circulation in search of acute pulmonary embolism (n = 28) or for management of tumoral disease (n = 9). CT angiography was performed (a) with four-detector row (n = 19) or 16-cletector row (n = 18) scanners; (b) at randomly assigned gadoliniurn doses of either 0.3 mmol per kilogram of body weight (n = 19) or 0.4 mmol/kg (n = 18); and (c) with a systematic evaluation of clinical and biologic tolerance of gadolinium. Comparison of percentages between group 1 and group 2 scans was performed with the chi(2) or the Fisher exact test. An unpaired Wilcoxon rank sum test was used for numeric variables. P <.05 was considered to indicate a significant difference. RESULTS: The mean (+/- standard deviation) volume of gaclopentetate dimeglumine administered in the overall study group was 48 mL +/- 9.6 (range, 29-65 mL). The level of maximal enhancement in the pulmonary arteries was significantly higher in group 2 than in group 1 (215.8 HU +/- 95 vs 141.3 HU +/- 44) (P =.02) and was maintained throughout the entire region of interest in a greater number of examinations in group 2 than in group 1 (n = 16 [89%] vs n = 2 [10.5%]) (P <.0001). The number of diagnostic CT angiograms was significantly higher in group 2 than in group I (n = 17 [94%] vs n = 13 [68%]) (P =.007). Significant but transient reduction of creatinine clearance was observed in one patient with preexisting moderate chronic renal failure (0.3 mmol/kg gadolinium dose). CONCLUSION: High-quality gadolinium-enhanced CT angiograms require the use of 16-detector row CT technology; the doses administered did not alter the renal function except transiently in one patient.((c)) 2005 RSNA.
引用
收藏
页码:819 / 826
页数:8
相关论文
共 32 条
[1]   Gadolinium-DTPA as X-ray contrast medium in clinical studies [J].
Albrecht, T ;
Dawson, P .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (872) :878-882
[2]   GD-DTPA AS A CONTRAST AGENT IN CT [J].
BLOEM, JL ;
WONDERGEM, J .
RADIOLOGY, 1989, 171 (02) :578-579
[3]   Demonstration of pulmonary embolism with dynamic gadolinium-enhanced spiral CT [J].
Coche, EE ;
Hammer, FD ;
Goffette, PP .
EUROPEAN RADIOLOGY, 2001, 11 (11) :2306-2309
[4]   A multi-centre longitudinal study comparing the sensitivity of monthly MRI after standard and triple dose gadolinium-DTPA for monitoring disease activity in multiple sclerosis -: Implications for phase II clinical trials [J].
Filippi, M ;
Rovaris, M ;
Capra, R ;
Gasperini, C ;
Yousry, TA ;
Sormani, MP ;
Prandini, F ;
Horsfield, MA ;
Martinelli, V ;
Bastianello, S ;
Kühne, I ;
Pozzilli, C ;
Comi, G .
BRAIN, 1998, 121 :2011-2020
[5]   Gadolinium as a CT contrast agent: Assessment in a porcine model [J].
Gierada, DS ;
Bae, KT .
RADIOLOGY, 1999, 210 (03) :829-834
[6]   Gadopentetate dimeglumine is potentially an alternative contrast agent for three-dimensional computed tomography angiography with multidetector-row helical scanning [J].
Gupta, AK ;
Alberico, RA ;
Litwin, A ;
Kanter, P ;
Grossman, ZD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (06) :869-874
[7]   Gadolinium dimeglumine: an alternative contrast agent for digital subtraction angiography [J].
Hammer, FD ;
Goffette, PP ;
Malaise, J ;
Mathurin, P .
EUROPEAN RADIOLOGY, 1999, 9 (01) :128-136
[8]   RENAL TOLERANCE OF GADOLINIUM-DTPA DIMEGLUMINE IN PATIENTS WITH CHRONIC-RENAL-FAILURE [J].
HAUSTEIN, J ;
NIENDORF, HP ;
KRESTIN, G ;
LOUTON, T ;
SCHUHMANNGIAMPIERI, G ;
CLAUSS, W ;
JUNGE, W .
INVESTIGATIVE RADIOLOGY, 1992, 27 (02) :153-156
[9]   Gadolinium-enhanced multidetector CT angiography of the thoracoabdominal aorta [J].
Karcaaltincaba, M ;
Foley, WD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (06) :875-878
[10]   ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST MEDIA [J].
KATAYAMA, H ;
YAMAGUCHI, K ;
KOZUKA, T ;
TAKASHIMA, T ;
SEEZ, P ;
MATSUURA, K .
RADIOLOGY, 1990, 175 (03) :621-628