A Magnetic-Balanced Inductive Link for the Simultaneous Uplink Data and Power Telemetry

被引:14
作者
Gong, Chen [1 ]
Liu, Dake [1 ]
Miao, Zhidong [1 ]
Li, Min [1 ]
机构
[1] Beijing Inst Technol, Inst Applicat Specif Instruct Set Processors, 5 South Zhongguancun St, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
biomedical telemetry; inductive link; simultaneous data and power transmissions; implantable biomedical sensors; intraocular sensors; WIRELESS LINK; BAND POWER; OPTIMIZATION; SYSTEM; COILS;
D O I
10.3390/s17081768
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
When using the conventional two-coil inductive link for the simultaneous wireless power and data transmissions in implantable biomedical sensor devices, the strong power carrier could overwhelm the uplink data signal and even saturate the external uplink receiver. To address this problem, we propose a new magnetic-balanced inductive link for our implantable glaucoma treatment device. In this inductive link, an extra coil is specially added for the uplink receiving. The strong power carrier interference is minimized to approach zero by balanced canceling of the magnetic field of the external power coil. The implant coil is shared by the wireless power harvesting and the uplink data transmitting. Two carriers (i.e., 2-MHz power carrier and 500-kHz uplink carrier) are used for the wireless power transmission and the uplink data transmission separately. In the experiments, the prototype of this link achieves as high as 65.72 dB improvement of the signal-to-interference ratio (SIR) compared with the conventional two-coil inductive link. Benefiting from the significant improvement of SIR, the implant transmitter costs only 0.2 mW of power carrying 50 kbps of binary phase shift keying data and gets a bit error rate of 1 x 10(-7), even though the coupling coefficient is as low as 0.005. At the same time, 5 mW is delivered to the load with maximum power transfer efficiency of 58.8%. This magnetic-balanced inductive link is useful for small-sized biomedical sensor devices, which require transmitting data and power simultaneously under ultra-weak coupling.
引用
收藏
页数:22
相关论文
共 38 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]  
Andreuccetti D, An Internet resource for the calculation of thedielectric properties of body tissues in the frequency range 10 Hz-100GHz
[3]  
[Anonymous], 2014, HDB BIOMEDICAL TELEM
[4]  
Caprioli Joseph, 2011, Bull Soc Belge Ophtalmol, P7
[5]   An inductive power system with integrated bi-directional data-transmission [J].
Catrysse, M ;
Hermans, B ;
Puers, R .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 115 (2-3) :221-229
[6]  
Chen Gong, 2015, 2015 IEEE Biomedical Circuits and Systems Conference (BioCAS), P1, DOI 10.1109/BioCAS.2015.7348288
[7]   Analytical Modeling and Optimization of Small Solenoid Coils for Millimeter-Sized Biomedical Implants [J].
Cheng, Yuhua ;
Wang, Gaofeng ;
Ghovanloo, Maysam .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2017, 65 (03) :1024-1035
[8]  
DAVANGER M, 1991, ACTA OPHTHALMOL, V69, P565
[9]   A Circadian and Cardiac Intraocular Pressure Sensor for Smart Implantable Lens [J].
Donida, Achille ;
Di Dato, Giuseppe ;
Cunzolo, Paolo ;
Sala, Marco ;
Piffaretti, Filippo ;
Orsatti, Paolo ;
Barrettino, Diego .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2015, 9 (06) :777-789
[10]  
Finkenzeller K., 2003, RFID HDB FUNDAMENTAL, P61