Knoop hardness of five composites cured with single-peak and polywave LED curing lights

被引:0
作者
Price, Richard B. T. [1 ]
Fahey, John [1 ]
Felix, Christopher M. [1 ]
机构
[1] Dalhousie Univ, Dept Clin Dent Sci, Halifax, NS B3H 1W2, Canada
来源
QUINTESSENCE INTERNATIONAL | 2010年 / 41卷 / 10期
基金
加拿大自然科学与工程研究理事会;
关键词
chemistry; composite resins; curing light; dental materials; hardness testing; Knoop microhardness; light-emitting diode; physical properties; radiation effects; DENTAL RESIN COMPOSITES; EMITTING-DIODE; MECHANICAL-PROPERTIES; RADIANT EXPOSURE; CONVERSION; UNITS; POLYMERIZATION; DISTANCE; DEPTH; TIME;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare the ability of four light-emitting diode (LED) curing lights to polymerize five composite resins in 10 seconds at 4 and 8 mm. Method and Materials: Two second-generation, single-peak LED curing lights (Bluephase 16i, Ivoclar Vivadent, and LEDemetron II, Kerr) and two third-generation polywave LED curing lights (UltraLume 5, Ultradent, and Bluephase G2, Ivoclar Vivadent) were compared. Three examples of each brand of curing light were used, and their light outputs were measured with a spectroradiometer. Five composite resins (Filtek Supreme A2B, 3M ESPE; Vit-l-escence A2, Ultradent; Aelite LS Posterior A2, Bisco; and Tetric EvoCeram A2 and Tetric EvoCeram Bleach M, both Ivoclar Vivadent) were polymerized for 10 seconds at 4 and 8 mm from the end of the light guide. The Knoop microhardness (KHN(50gf)) was measured at 49 locations across the top and bottom surfaces of the specimens to determine the ability of each light to cure each brand of composite in 10 seconds. Results: At 4 and 8 mm, the Bluephase G2 light delivered the broadest spectral range of wavelengths, greatest irradiance, and energy density. The Bluephase G2 always produced harder, better-cured resins compared to the other three lights. Overall, the ability of the lights to cure these five composites was ranked from highest to lowest: Bluephase G2, UltraLume 5, Bluephase 16i, and LEDemetron II (ANOVA with REGWQ multiple comparison test, P < .01). Conclusion: This study suggests that polywave LED curing lights should be used in preference to single-peak LED curing lights. (Quintessence Int 2010; 41: e181-e191)
引用
收藏
页码:E181 / E191
页数:11
相关论文
共 50 条
  • [1] Analysis of camphorquinone in composite resins as a function of shade
    Alvim, Hugo H.
    Alecio, Alberto C.
    Vasconcellos, Walison A.
    Furlan, Maysa
    de Oliveira, Jose E.
    Saad, Jose R. C.
    [J]. DENTAL MATERIALS, 2007, 23 (10) : 1245 - 1249
  • [2] Effect of inhomogeneity of light from light curing units on the surface hardness of composite resin
    Arikawa, Hiroyuki
    Kanie, Takahito
    Fujii, Koichi
    Takahashi, Hideo
    Ban, Seiji
    [J]. DENTAL MATERIALS JOURNAL, 2008, 27 (01) : 21 - 28
  • [3] Performance of two blue light-emitting-diode dental light curing units with distance and irradiation-time
    Bennett, AW
    Watts, DC
    [J]. DENTAL MATERIALS, 2004, 20 (01) : 72 - 79
  • [4] Degree of conversion and mechanical properties of a BisGMA:TEGDMA composite as a function of the applied radiant exposure
    Calheiros, Fernanda C.
    Daronch, Marcia
    Rueggeberg, Frederick A.
    Braga, Roberto R.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 84B (02) : 503 - 509
  • [5] Influence of radiant exposure on contraction stress, degree of conversion and mechanical properties of resin composites
    Calheiros, Fernanda C.
    Kawano, Yoshio
    Stansbury, Jeffrey W.
    Braga, Roberto R.
    [J]. DENTAL MATERIALS, 2006, 22 (09) : 799 - 803
  • [6] The influence of tip geometry and distance on light-curing efficacy
    Corciolani, G.
    Vichi, A.
    Davidson, C. L.
    Ferrari, M.
    [J]. OPERATIVE DENTISTRY, 2008, 33 (03) : 325 - 331
  • [7] Ernst CP., 2006, DTSCH ZAHN RZTLICHE, V61, P466
  • [8] Curing-light intensity and depth of cure of resin-based composites tested according to international standards
    Fan, PL
    Schumacher, RM
    Azzolin, K
    Geary, R
    Eichmiller, FC
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2002, 133 (04) : 429 - 434
  • [9] Ferracane J L, 1985, Dent Mater, V1, P11, DOI 10.1016/S0109-5641(85)80058-0
  • [10] Oxygen inhibition in dental resins
    Gauthier, MA
    Stangel, I
    Ellis, TH
    Zhu, XX
    [J]. JOURNAL OF DENTAL RESEARCH, 2005, 84 (08) : 725 - 729