Dual-source CT coronary angiography: Image quality, mean heart rate, and heart rate variability

被引:128
|
作者
Matt, David
Scheffel, Hans
Leschka, Sebastian
Flohr, Thomas G.
Marincek, Borut
Kaufmann, Philipp A.
Alkadhi, Hatem
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Siemens Med Solut, Forchheim, Germany
[3] Univ Zurich Hosp, Ctr Cardiovasc, CH-8091 Zurich, Switzerland
[4] Zurich Ctr Integrat Human Physiol, Zurich, Switzerland
关键词
coronary angiography; dual-source CT; heart rate; image quality;
D O I
10.2214/AJR.07.2078
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the effect of mean heart rate and heart rate variability on the image quality of dual-source CT coronary angiography. SUBJECTS AND METHODS. Eighty patients underwent dual-source CT coronary angiography. Thirteen data sets were reconstructed in 5% steps from 20-80% of the R-R interval. Heart rate variability was calculated as SD of mean heart rate. Two independent blinded reviewers assessed the image quality of each segment. RESULTS. Mean heart rate was 65.3 +/- 13.9 (SD) beats per minute (bpm) (range, 35-99 bpm) with a variability of 3.4 +/- 4.1 bpm (range, 0.4-17.5 bpm). Image quality was sufficient for diagnosis for 97.8% (1,043/1,066) of arterial segments. No significant correlation was found between mean heart rate and image quality in any segment or any coronary artery. No significant correlation was found between heart rate variability and image quality in any segment, the right coronary artery, or the left anterior descending artery, but there was a significant (p < 0.05) correlation in the left circumflex artery. A significant correlation (p < 0.05) between overall image quality was found for mean and variability of heart rate as shared predictors, the latter having a greater contribution. CONCLUSION. The overall image quality of dual-source CT coronary angiography is sufficient for diagnosis within a wide range of mean heart rates and variability of heart rates. Only heart rates that are both high and variable significantly deteriorate image quality, but the quality remains adequate for diagnosis.
引用
收藏
页码:567 / 573
页数:7
相关论文
共 50 条
  • [41] Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy
    Alkadhi, Hatem
    Scheffel, Hans
    Desbiolles, Lotus
    Gaemperli, Oliver
    Stolzmann, Paul
    Plass, Andre
    Goerres, Gerhard W.
    Luescher, Thomas F.
    Genoni, Michele
    Marincek, Borut
    Kaufmann, Philipp A.
    Leschka, Sebastian
    EUROPEAN HEART JOURNAL, 2008, 29 (06) : 766 - 776
  • [42] Limits of the possible: diagnostic image quality in coronary angiography with third-generation dual-source CT
    Marco M. Ochs
    Fabian aus dem Siepen
    Thomas Fritz
    Florian Andre
    Gitsios Gitsioudis
    Grigorios Korosoglou
    Sebastian Seitz
    Yuriy Bogomazov
    Christopher L. Schlett
    Roman Sokiranski
    Andre Sommer
    Friedemann Gückel
    Matthias Brado
    Hans-Ulrich Kauczor
    Johannes Görich
    Matthias G. W. Friedrich
    Hugo A. Katus
    Sebastian J. Buss
    Clinical Research in Cardiology, 2017, 106 : 485 - 492
  • [43] Failed heart rate control with oral metoprolol prior to coronary CT angiography: effect of additional intravenous metoprolol on heart rate, image quality and radiation dose
    Jimenez-Juan, Laura
    Nguyen, Elsie T.
    Wintersperger, Bernd J.
    Moshonov, Hadas
    Crean, Andrew M.
    Deva, Djeven P.
    Paul, Narinder S.
    Torres, Felipe S.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (01) : 199 - 206
  • [44] Failed heart rate control with oral metoprolol prior to coronary CT angiography: effect of additional intravenous metoprolol on heart rate, image quality and radiation dose
    Laura Jiménez-Juan
    Elsie T. Nguyen
    Bernd J. Wintersperger
    Hadas Moshonov
    Andrew M. Crean
    Djeven P. Deva
    Narinder S. Paul
    Felipe S. Torres
    The International Journal of Cardiovascular Imaging, 2013, 29 : 199 - 206
  • [45] Limits of the possible: diagnostic image quality in coronary angiography with third-generation dual-source CT
    Ochs, Marco M.
    Siepen, Fabian Aus Dem
    Fritz, Thomas
    Andre, Florian
    Gitsioudis, Gitsios
    Korosoglou, Grigorios
    Seitz, Sebastian
    Bogomazov, Yuriy
    Schlett, Christopher L.
    Sokiranski, Roman
    Sommer, Andre
    Gueckel, Friedemann
    Brado, Matthias
    Kauczor, Hans-Ulrich
    Goerich, Johannes
    Friedrich, Matthias G. W.
    Katus, Hugo A.
    Buss, Sebastian J.
    CLINICAL RESEARCH IN CARDIOLOGY, 2017, 106 (07) : 485 - 492
  • [46] Dual-Source Versus Single-Source Cardiac CT Angiography: Comparison of Diagnostic Image Quality
    Donnino, Robert
    Jacobs, Jill E.
    Doshi, Jay V.
    Hecht, Elizabeth M.
    Kim, Danny C.
    Babb, James S.
    Srichai, Monvadi B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) : 1051 - 1056
  • [47] Subtraction coronary CT angiography in patients with high heart rate
    Zhou, Bi
    Tang, Zhuoyue
    Huang, Xianlong
    Zhu, Hongzhang
    Li, Xiaojiao
    Xiong, Hua
    Yu, Jiayi
    Liao, Ruikun
    Zhang, Dan
    ACTA CARDIOLOGICA, 2023, 78 (01) : 99 - 108
  • [48] Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control
    Hans Scheffel
    Hatem Alkadhi
    André Plass
    Robert Vachenauer
    Lotus Desbiolles
    Oliver Gaemperli
    Tiziano Schepis
    Thomas Frauenfelder
    Thomas Schertler
    Lars Husmann
    Jürg Grunenfelder
    Michele Genoni
    Philipp A. Kaufmann
    Borut Marincek
    Sebastian Leschka
    European Radiology, 2006, 16 : 2739 - 2747
  • [49] Dual-source CT for visualization of the coronary arteries in heart transplant patients with high heart rates
    Bastarrika, Gorka
    Nicola De Cecco, Carlo
    Arraiza, Maria
    Mastrobuoni, Stefano
    Pueyo, Jesus C.
    Ubilla, Matias
    Rabago, Gregorio
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (02) : 448 - 454
  • [50] Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control
    Scheffel, Hans
    Alkadhi, Hatem
    Plass, Andre
    Vachenauer, Robert
    Desbiolles, Lotus
    Gaemperli, Oliver
    Schepis, Tiziano
    Frauenfelder, Thomas
    Schertler, Thomas
    Husmann, Lars
    Grunenfelder, Juerg
    Genoni, Michele
    Kaufmann, Philipp A.
    Marincek, Borut
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2006, 16 (12) : 2739 - 2747