Dual-source CT coronary angiography: Image quality, mean heart rate, and heart rate variability

被引:128
|
作者
Matt, David
Scheffel, Hans
Leschka, Sebastian
Flohr, Thomas G.
Marincek, Borut
Kaufmann, Philipp A.
Alkadhi, Hatem
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Siemens Med Solut, Forchheim, Germany
[3] Univ Zurich Hosp, Ctr Cardiovasc, CH-8091 Zurich, Switzerland
[4] Zurich Ctr Integrat Human Physiol, Zurich, Switzerland
关键词
coronary angiography; dual-source CT; heart rate; image quality;
D O I
10.2214/AJR.07.2078
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the effect of mean heart rate and heart rate variability on the image quality of dual-source CT coronary angiography. SUBJECTS AND METHODS. Eighty patients underwent dual-source CT coronary angiography. Thirteen data sets were reconstructed in 5% steps from 20-80% of the R-R interval. Heart rate variability was calculated as SD of mean heart rate. Two independent blinded reviewers assessed the image quality of each segment. RESULTS. Mean heart rate was 65.3 +/- 13.9 (SD) beats per minute (bpm) (range, 35-99 bpm) with a variability of 3.4 +/- 4.1 bpm (range, 0.4-17.5 bpm). Image quality was sufficient for diagnosis for 97.8% (1,043/1,066) of arterial segments. No significant correlation was found between mean heart rate and image quality in any segment or any coronary artery. No significant correlation was found between heart rate variability and image quality in any segment, the right coronary artery, or the left anterior descending artery, but there was a significant (p < 0.05) correlation in the left circumflex artery. A significant correlation (p < 0.05) between overall image quality was found for mean and variability of heart rate as shared predictors, the latter having a greater contribution. CONCLUSION. The overall image quality of dual-source CT coronary angiography is sufficient for diagnosis within a wide range of mean heart rates and variability of heart rates. Only heart rates that are both high and variable significantly deteriorate image quality, but the quality remains adequate for diagnosis.
引用
收藏
页码:567 / 573
页数:7
相关论文
共 50 条
  • [21] Effect of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of the Dual-Source CT Coronary Angiography in Patients with Suspected Coronary Artery Disease
    Meng, Lingdong
    Cui, Lianqun
    Cheng, Yuntao
    Wu, Xiaoyan
    Tang, Yuansheng
    Wang, Yong
    Xu, Fayun
    KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (04) : 347 - 354
  • [22] Image quality on dual-source computed-tomographic coronary angiography
    Johannes Rixe
    Andreas Rolf
    Guido Conradi
    Albrecht Elsaesser
    Helge Moellmann
    Holger M. Nef
    Georg Bachmann
    Christian W. Hamm
    Thorsten Dill
    European Radiology, 2008, 18 : 1857 - 1862
  • [23] Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients
    Ming-li Sun
    Bin Lu
    Run-ze Wu
    Laura Johnson
    Lei Han
    Gang Liu
    Fang-Fang Yu
    Zhi-hui Hou
    Yang Gao
    Hong-yu Wang
    Shiliang Jiang
    Yue-jin Yang
    Shu-bin Qiao
    European Radiology, 2011, 21 : 1635 - 1642
  • [24] Step and shoot coronary CT angiography using 256-slice CT: effect of heart rate and heart rate variability on image quality
    D. Muenzel
    P. B. Noel
    F. Dorn
    M. Dobritz
    E. J. Rummeny
    A. Huber
    European Radiology, 2011, 21 : 2277 - 2284
  • [25] Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients
    Ghazal Adler
    Laurent Meille
    Adela Rohnean
    Anne Sigal-Cinqualbre
    André Capderou
    Jean-François Paul
    European Radiology, 2010, 20 : 1118 - 1123
  • [26] Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients
    Adler, Ghazal
    Meille, Laurent
    Rohnean, Adela
    Sigal-Cinqualbre, Anne
    Capderou, Andre
    Paul, Jean-Francois
    EUROPEAN RADIOLOGY, 2010, 20 (05) : 1118 - 1123
  • [27] Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography
    Philip A. Araoz
    Jacobo Kirsch
    Andrew N. Primak
    Natalie N. Braun
    Osama Saba
    Eric E. Williamson
    W. Scott Harmsen
    Jayawant N. Mandrekar
    Cynthia H. McCollough
    The International Journal of Cardiovascular Imaging, 2009, 25 : 837 - 845
  • [28] Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography
    Araoz, Philip A.
    Kirsch, Jacobo
    Primak, Andrew N.
    Braun, Natalie N.
    Saba, Osama
    Williamson, Eric E.
    Harmsen, W. Scott
    Mandrekar, Jayawant N.
    McCollough, Cynthia H.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (08) : 837 - 845
  • [29] Dual-source CT coronary angiography: image quality and optimal reconstruction interval
    Bastarrika, G.
    Arraiza, M.
    Arias, J.
    Broncano, J.
    Zudaire, B.
    Pueyo, J. C.
    del Barrio, Y. L. Garcia
    RADIOLOGIA, 2009, 51 (04): : 376 - 384
  • [30] Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiography
    Xiaomei Zhu
    Wenping Chen
    Mei Li
    Yi Xu
    Hai Xu
    Yinsu Zhu
    Dehang Wang
    Lijun Tang
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1557 - 1565