Dual-source CT coronary angiography: Image quality, mean heart rate, and heart rate variability

被引:128
|
作者
Matt, David
Scheffel, Hans
Leschka, Sebastian
Flohr, Thomas G.
Marincek, Borut
Kaufmann, Philipp A.
Alkadhi, Hatem
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Siemens Med Solut, Forchheim, Germany
[3] Univ Zurich Hosp, Ctr Cardiovasc, CH-8091 Zurich, Switzerland
[4] Zurich Ctr Integrat Human Physiol, Zurich, Switzerland
关键词
coronary angiography; dual-source CT; heart rate; image quality;
D O I
10.2214/AJR.07.2078
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the effect of mean heart rate and heart rate variability on the image quality of dual-source CT coronary angiography. SUBJECTS AND METHODS. Eighty patients underwent dual-source CT coronary angiography. Thirteen data sets were reconstructed in 5% steps from 20-80% of the R-R interval. Heart rate variability was calculated as SD of mean heart rate. Two independent blinded reviewers assessed the image quality of each segment. RESULTS. Mean heart rate was 65.3 +/- 13.9 (SD) beats per minute (bpm) (range, 35-99 bpm) with a variability of 3.4 +/- 4.1 bpm (range, 0.4-17.5 bpm). Image quality was sufficient for diagnosis for 97.8% (1,043/1,066) of arterial segments. No significant correlation was found between mean heart rate and image quality in any segment or any coronary artery. No significant correlation was found between heart rate variability and image quality in any segment, the right coronary artery, or the left anterior descending artery, but there was a significant (p < 0.05) correlation in the left circumflex artery. A significant correlation (p < 0.05) between overall image quality was found for mean and variability of heart rate as shared predictors, the latter having a greater contribution. CONCLUSION. The overall image quality of dual-source CT coronary angiography is sufficient for diagnosis within a wide range of mean heart rates and variability of heart rates. Only heart rates that are both high and variable significantly deteriorate image quality, but the quality remains adequate for diagnosis.
引用
收藏
页码:567 / 573
页数:7
相关论文
共 50 条
  • [1] Relationship between Heart Rate and Optimal Reconstruction Phase in Dual-source CT Coronary Angiography
    Horii, Yosuke
    Yoshimura, Norihiko
    Hori, Yoshiro
    Takano, Toru
    Inagawa, Shoichi
    Akazawa, Kohei
    Aoyama, Hidefumi
    ACADEMIC RADIOLOGY, 2011, 18 (06) : 726 - 730
  • [2] Dual-source computed tomography coronary angiography in patients with high heart rate
    Fujimura, Tatsuhiro
    Miura, Toshiro
    Nao, Tomoko
    Yoshimura, Masayuki
    Nakashima, Yoshiteru
    Okada, Munemasa
    Okamura, Takayuki
    Yamada, Jutaro
    Ohshita, Chikage
    Wada, Yasuaki
    Matsunaga, Naofumi
    Matsuzaki, Masunori
    Yano, Masafumi
    HEART AND VESSELS, 2014, 29 (04) : 443 - 448
  • [3] Diagnostic Quality of Dual-Source Coronary CT Examinations Performed Without Heart Rate Control: Importance of Obesity and Heart Rate on Image Quality
    Zimmerman, Stefan L.
    Kral, Brian G.
    Fishman, Elliot K.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 949 - 955
  • [4] Dual-source computed tomography coronary angiography in patients with high heart rate
    Tatsuhiro Fujimura
    Toshiro Miura
    Tomoko Nao
    Masayuki Yoshimura
    Yoshiteru Nakashima
    Munemasa Okada
    Takayuki Okamura
    Jutaro Yamada
    Chikage Ohshita
    Yasuaki Wada
    Naofumi Matsunaga
    Masunori Matsuzaki
    Masafumi Yano
    Heart and Vessels, 2014, 29 : 443 - 448
  • [5] Low-dose CT Coronary Angiography Using Prospective ECG-Triggering: Impact of Mean Heart Rate and Heart Rate Variability on Image Quality
    Herzog, Bernhard A.
    Husmann, Lars
    Burkhard, Nina
    Valenta, Ines
    Gaemperli, Oliver
    Tatsugami, Fuminari
    Wyss, Christophe A.
    Landmesser, Ulf
    Kaufmann, Philipp A.
    ACADEMIC RADIOLOGY, 2009, 16 (01) : 15 - 21
  • [6] Systolic reconstruction in patients with low heart rate using coronary dual-source CT angiography
    Okada, Munemasa
    Nakashima, Yoshiteru
    Shigemoto, Youko
    Matsunaga, Naofumi
    Miura, Toshiro
    Nao, Tomoko
    Sano, Yuichi
    Narazaki, Akiko
    Kido, Shoji
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 336 - 341
  • [7] Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective
    Zhang, Long-Jiang
    Wu, Sheng-Yong
    Wang, Jing
    Lu, Ying
    Zhang, Zhuo-Li
    Jiang, Shi-Sen
    Zhou, Chang-Sheng
    Lu, Guang-Ming
    ACTA RADIOLOGICA, 2010, 51 (07) : 727 - 740
  • [8] 256-slice CT coronary angiography in atrial fibrillation: The impact of mean heart rate and heart rate variability on image quality
    Chen, Liang-Kuang
    Hsu, Shih-Ming
    Mok, Greta S. P.
    Law, Wei-Yip
    Lu, Kun-Mu
    Yang, Ching-Ching
    Wu, Tung-Hsin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S153 - S157
  • [9] Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography
    Fang, Xiang Ming
    Chen, Hong Wei
    Hu, Xiao Yun
    Bao, Jian
    Chen, Yin
    Yang, Zhen Yu
    Buckley, Orla
    Wu, Xiao Qing
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (03) : 323 - 331
  • [10] High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate
    Gordic, Sonja
    Husarik, Daniela B.
    Desbiolles, Lotus
    Leschka, Sebastian
    Frauenfelder, Thomas
    Alkadhi, Hatem
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (06) : 1173 - 1179