Extra-articular distal radius malunion: The phosphate cement alternative

被引:5
作者
Obert, L. [1 ]
Lepage, D. [1 ]
Gasse, N. [1 ]
Rochet, S. [1 ]
Garbuio, P. [1 ]
机构
[1] Univ Franche Comte, Orthoped Traumatol Plast & Reconstruct Hand Surg, Surg Innovat & Tech Ctr, INSERM,EA 4268,IFR 133,Jean Minjoz Univ Hosp, F-25030 Besancon, France
关键词
Malunion; Distal radius; Osteotomy; Calcium phosphate cements; Bone substitutes; OSTEOTOMY; FRACTURES;
D O I
10.1016/j.otsr.2010.03.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Five consecutive patients (mean age: 40.4 yrs (range, 19-58 yrs)), with symptomatic distal radius malunion underwent corrective opening wedge osteotomy using phosphate cement as an alternative to bone autograft, at a mean 9 months (4-16 mo) of fracture. Internal fixation used a plate placed just above the distal radioulnar joint, with soft-tissue release. Radiographic and functional parameters were measured before surgery, and at 6 months and 1 year. At a mean 32.4 months (range, 16-47 mo), all patients were satisfied and all the osteotomies were united. At 1 year's follow-up, wrist range of motion reached 75% compared to the contralateral side. Two biopsies performed during plate removal showed osteoid tissue at the cement-bone junction. It is reasonable to consider injectable phosphate cement as a viable alternative to bone grafting in conjunction with surgical correction of distal radius malunion. Level of evidence: level IV. (C) 2010 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:574 / 578
页数:5
相关论文
共 10 条
  • [1] Osteotomy of dorsally displaced malunited fractures of the distal radius -: No loss of radiographic correction during healing with a minimally invasive fixation technique and an injectable bone substitute
    Abramo, Antonio
    Tagill, Magnus
    Geijer, Mats
    Kopylov, Philippe
    [J]. ACTA ORTHOPAEDICA, 2008, 79 (02) : 262 - 268
  • [2] ALLIEU Y, 1984, Annales de Chirurgie de la Main, V3, P317, DOI 10.1016/S0753-9053(84)80006-X
  • [3] Gupta AR, 2001, INT MED J, V8, P163
  • [4] Corrective osteotomy for malunited extra-articular fractures of the distal radius: A follow-up study of 33 patients
    Krukhaug, Yngvar
    Hove, Leiv M.
    [J]. SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2007, 41 (06): : 303 - 309
  • [5] Distal radius osteotomy in the elderly patient using angular stable implants and Norian bone cement
    Lozano-Calderon, Santiago
    Moore, Michael
    Liebman, Matthew
    Jupiter, Jesse B.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (07): : 976 - 983
  • [6] Corrective osteotomy of malunited distal radius fractures using carbonated hydroxyapatite as an alternative to autogenous bone grafting
    Luchetti, R
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (05): : 825 - 834
  • [7] OBERT L, 2006, FRACTURES RADIUS DIS, P529
  • [8] Prommersberger K J, 1999, Handchir Mikrochir Plast Chir, V31, P221, DOI 10.1055/s-1999-13905
  • [9] Voche P, 2001, REV CHIR ORTHOP, V87, P263
  • [10] Zyluk Andrzej, 2008, Chir Narzadow Ruchu Ortop Pol, V73, P41