Detection of embolic particles with the Doppler guide wire during coronary intervention in patients with acute myocardial infarction - Efficacy of distal protection device
被引:72
作者:
Okamura, A
论文数: 0引用数: 0
h-index: 0
机构:Sakurabashi Watanabe Hosp, Div Cardiol, Kita Ku, Osaka 5300001, Japan
Okamura, A
Ito, H
论文数: 0引用数: 0
h-index: 0
机构:Sakurabashi Watanabe Hosp, Div Cardiol, Kita Ku, Osaka 5300001, Japan
Ito, H
Iwakura, K
论文数: 0引用数: 0
h-index: 0
机构:Sakurabashi Watanabe Hosp, Div Cardiol, Kita Ku, Osaka 5300001, Japan
Iwakura, K
Kawano, S
论文数: 0引用数: 0
h-index: 0
机构:Sakurabashi Watanabe Hosp, Div Cardiol, Kita Ku, Osaka 5300001, Japan
Kawano, S
Inoue, K
论文数: 0引用数: 0
h-index: 0
机构:Sakurabashi Watanabe Hosp, Div Cardiol, Kita Ku, Osaka 5300001, Japan
Inoue, K
Maekawa, Y
论文数: 0引用数: 0
h-index: 0
机构:Sakurabashi Watanabe Hosp, Div Cardiol, Kita Ku, Osaka 5300001, Japan
Maekawa, Y
Ogihara, T
论文数: 0引用数: 0
h-index: 0
机构:Sakurabashi Watanabe Hosp, Div Cardiol, Kita Ku, Osaka 5300001, Japan
Ogihara, T
Fujii, K
论文数: 0引用数: 0
h-index: 0
机构:Sakurabashi Watanabe Hosp, Div Cardiol, Kita Ku, Osaka 5300001, Japan
Fujii, K
机构:
[1] Sakurabashi Watanabe Hosp, Div Cardiol, Kita Ku, Osaka 5300001, Japan
[2] Osaka Univ, Grad Sch Med, Dept Geriatr Med, Osaka, Japan
OBJECTIVES We investigated whether embolic particles could be detected as high-intensity transient signals (HITS) with a Doppler guide wire during percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI) We also assessed whether these signals could be reduced using a distal protection (DP) device. BACKGROUND Embolization of thrombi and plaque components to the microcirculation is a major complication of PCI in patients with AMI. Embolic particles running in the cerebral artery are detected as HITS by transcranial Doppler ultrasound. METHODS We prospectively studied 16 consecutive patients with AMI who underwent direct PCI within 24 h after the onset of symptoms. A PercuSurge GuardWire (MedtronicAVE, Santa Rosa, California) was used as the DP device. Eight patients were randomly assigned to the non-DP group, and the remaining eight were assigned to the DP group. Coronary flow velocity was recorded continuously from before the first balloon inflation to after balloon deflation. RESULTS All patients in the non-DP group had HITS detected (12 +/- 9 counts) within five consecutive beats (4 +/- 1 beat) after balloon deflation, but none were detected in any of the patients in the DP group. CONCLUSIONS The Doppler guide wire can be used to visually detect and count emboli as HITS, and the DP device is effiective for prevention of distal embolization. (C) 2005 by the American College of Cardiology Foundation.